{"title":"Meters \u0026 Energy Monitoring","description":"\u003cp\u003e\u003cstrong data-start=\"0\" data-end=\"30\" data-is-only-node=\"\"\u003eMeters \u0026amp; Energy Monitoring\u003c\/strong\u003e solutions include energy meters, power meters, monitoring devices, and data management tools for measuring and analyzing electrical consumption. They help improve energy efficiency, optimize system performance, and support effective energy management.\u003c\/p\u003e","products":[{"product_id":"phoenix-contact-mm-ee-eem-ma500-compact-energy-measuring-device-3-phase-modbus-part-no-1484138","title":"MM-EE-EEM-MA500 Multifunction Energy Meter 600V Pulse Output DIN Rail Meter 1484138","description":"\u003cp data-start=\"113\" data-end=\"911\"\u003eThe Phoenix Contact MM-EE-EEM-MA500 Multifunction Energy Meter (Part No. 1484138) is a high-precision electrical measuring device designed for monitoring and analyzing energy consumption in industrial, commercial, and building automation applications. Capable of measuring key electrical parameters in systems up to 600 V, this multifunction meter provides accurate energy management and power monitoring. Featuring a pulse output interface for integration with external monitoring and automation systems, it enables efficient data collection and energy tracking. Designed for reliable operation in demanding environments, it supports operating temperatures up to +70°C, making it ideal for control panels, power distribution systems, and industrial installations.\u003c\/p\u003e\n\u003cp data-start=\"913\" data-end=\"929\"\u003e\u003cstrong data-start=\"913\" data-end=\"929\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"930\" data-end=\"1499\"\u003e\n\u003cli data-section-id=\"15o7tk\" data-start=\"930\" data-end=\"968\"\u003ePhoenix Contact Part Number: 1484138\u003c\/li\u003e\n\u003cli data-section-id=\"14xfsuc\" data-start=\"969\" data-end=\"993\"\u003eModel: MM-EE-EEM-MA500\u003c\/li\u003e\n\u003cli data-section-id=\"1sxdl1m\" data-start=\"994\" data-end=\"1022\"\u003eMultifunction energy meter\u003c\/li\u003e\n\u003cli data-section-id=\"5asia1\" data-start=\"1023\" data-end=\"1067\"\u003eMeasures electrical parameters up to 600 V\u003c\/li\u003e\n\u003cli data-section-id=\"1b33xvw\" data-start=\"1068\" data-end=\"1115\"\u003ePulse output interface for monitoring systems\u003c\/li\u003e\n\u003cli data-section-id=\"1ps8k4a\" data-start=\"1116\" data-end=\"1161\"\u003eSuitable for energy management applications\u003c\/li\u003e\n\u003cli data-section-id=\"1pkmluq\" data-start=\"1162\" data-end=\"1201\"\u003eAccurate power and energy measurement\u003c\/li\u003e\n\u003cli data-section-id=\"5blasq\" data-start=\"1202\" data-end=\"1233\"\u003eIndustrial-grade construction\u003c\/li\u003e\n\u003cli data-section-id=\"dtd314\" data-start=\"1234\" data-end=\"1269\"\u003eOperating temperature up to +70°C\u003c\/li\u003e\n\u003cli data-section-id=\"1odz0e5\" data-start=\"1270\" data-end=\"1324\"\u003eSuitable for commercial and industrial installations\u003c\/li\u003e\n\u003cli data-section-id=\"1r3ypgq\" data-start=\"1325\" data-end=\"1377\"\u003eSupports electrical system monitoring and analysis\u003c\/li\u003e\n\u003cli data-section-id=\"potv5j\" data-start=\"1378\" data-end=\"1450\"\u003eIdeal for switchboards, control panels, and power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"qepb3i\" data-start=\"1451\" data-end=\"1499\"\u003eReliable performance in demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1501\" data-end=\"1517\"\u003e\u003cstrong data-start=\"1501\" data-end=\"1517\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1518\" data-end=\"1740\"\u003e\n\u003cli data-section-id=\"72ux80\" data-start=\"1518\" data-end=\"1545\"\u003eEnergy monitoring systems\u003c\/li\u003e\n\u003cli data-section-id=\"rb6wls\" data-start=\"1546\" data-end=\"1569\"\u003eIndustrial automation\u003c\/li\u003e\n\u003cli data-section-id=\"1vpv2cm\" data-start=\"1570\" data-end=\"1605\"\u003eBuilding management systems (BMS)\u003c\/li\u003e\n\u003cli data-section-id=\"zu8o49\" data-start=\"1606\" data-end=\"1638\"\u003eElectrical distribution panels\u003c\/li\u003e\n\u003cli data-section-id=\"c0rhxy\" data-start=\"1639\" data-end=\"1665\"\u003ePower quality monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"18o4vjw\" data-start=\"1666\" data-end=\"1694\"\u003eFacility energy management\u003c\/li\u003e\n\u003cli data-section-id=\"y90wz1\" data-start=\"1695\" data-end=\"1740\"\u003eCommercial and industrial power measurement\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":54163102236963,"sku":null,"price":2000.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00198974_full_b1500.jpg?v=1753016734"},{"product_id":"clamp-current-transformer-lmck-24-50-5a-accuracy-class-1-3-split-core-clamp-on","title":"Clamp Current Transformer LMCK-24 • 50\/5A • Accuracy Class 1.3 • Split-Core \/ Clamp-On","description":"\u003ch2 data-start=\"358\" data-end=\"380\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"382\" data-end=\"396\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"397\" data-end=\"767\"\u003eThe \u003cstrong data-start=\"401\" data-end=\"437\"\u003eLMCK-24 50\/5A Accuracy Class 1.3\u003c\/strong\u003e is a clamp-on, split-core current transformer designed for safe, accurate measurement of AC currents without needing to disconnect or reroute wires. With a primary rating of 50 A and a secondary of 5 A, this CT is ideal for metering, protection, and monitoring applications in industrial, commercial, or residential environments.\u003c\/p\u003e\n\u003chr data-start=\"769\" data-end=\"772\"\u003e\n\u003ch3 data-start=\"774\" data-end=\"790\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"792\" data-end=\"1835\"\u003e\n\u003cli data-start=\"792\" data-end=\"814\"\u003e\n\u003cp data-start=\"794\" data-end=\"814\"\u003e\u003cstrong data-start=\"794\" data-end=\"803\"\u003eModel\u003c\/strong\u003e: LMCK-24\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"815\" data-end=\"852\"\u003e\n\u003cp data-start=\"817\" data-end=\"852\"\u003e\u003cstrong data-start=\"817\" data-end=\"841\"\u003ePrimary Current (In)\u003c\/strong\u003e: 50 A AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"853\" data-end=\"924\"\u003e\n\u003cp data-start=\"855\" data-end=\"924\"\u003e\u003cstrong data-start=\"855\" data-end=\"881\"\u003eSecondary Current (Is)\u003c\/strong\u003e: 5 A AC — consistent current ratio 50\/5A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"925\" data-end=\"973\"\u003e\n\u003cp data-start=\"927\" data-end=\"973\"\u003e\u003cstrong data-start=\"927\" data-end=\"945\"\u003eAccuracy Class\u003c\/strong\u003e: 1.3 (i.e. 1.3% accuracy)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"974\" data-end=\"1089\"\u003e\n\u003cp data-start=\"976\" data-end=\"1089\"\u003e\u003cstrong data-start=\"976\" data-end=\"984\"\u003eType\u003c\/strong\u003e: Clamp-on \/ split-core design — allows installation around conductors without interrupting the circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1090\" data-end=\"1250\"\u003e\n\u003cp data-start=\"1092\" data-end=\"1250\"\u003e\u003cstrong data-start=\"1092\" data-end=\"1125\"\u003eInner Diameter (Core Opening)\u003c\/strong\u003e: 24 mm — fits conductors sized accordingly without tight bending or unsafe clearance \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1251\" data-end=\"1390\"\u003e\n\u003cp data-start=\"1253\" data-end=\"1390\"\u003e\u003cstrong data-start=\"1253\" data-end=\"1279\"\u003eRated Secondary Output\u003c\/strong\u003e: 5 A; typically used with compatible measurement or monitoring devices \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1391\" data-end=\"1611\"\u003e\n\u003cp data-start=\"1393\" data-end=\"1611\"\u003e\u003cstrong data-start=\"1393\" data-end=\"1413\"\u003eHousing \u0026amp; Safety\u003c\/strong\u003e: Flame retardant plastic enclosure, moisture protected; designed for robust service with low maintenance. The external case meets safety\/isolation standards. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1612\" data-end=\"1835\"\u003e\n\u003cp data-start=\"1614\" data-end=\"1835\"\u003e\u003cstrong data-start=\"1614\" data-end=\"1630\"\u003eInstallation\u003c\/strong\u003e: Self-locking clamp mechanism for quick, safe installation; no need for rewiring the primary conductor or shutting off power (depending on local safety regulations) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1842\" data-end=\"1870\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1872\" data-end=\"2995\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1872\" data-end=\"1972\"\u003e\n\u003ctr data-start=\"1872\" data-end=\"1972\"\u003e\n\u003cth data-start=\"1872\" data-end=\"1898\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1898\" data-end=\"1972\" data-col-size=\"md\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2075\" data-end=\"2995\"\u003e\n\u003ctr data-start=\"2075\" data-end=\"2176\"\u003e\n\u003ctd data-start=\"2075\" data-end=\"2102\" data-col-size=\"sm\"\u003ePrimary current rating\u003c\/td\u003e\n\u003ctd data-start=\"2102\" data-end=\"2176\" data-col-size=\"md\"\u003e50 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2177\" data-end=\"2278\"\u003e\n\u003ctd data-start=\"2177\" data-end=\"2204\" data-col-size=\"sm\"\u003eSecondary current rating\u003c\/td\u003e\n\u003ctd data-start=\"2204\" data-end=\"2278\" data-col-size=\"md\"\u003e5 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2279\" data-end=\"2381\"\u003e\n\u003ctd data-start=\"2279\" data-end=\"2306\" data-col-size=\"sm\"\u003eAccuracy class\u003c\/td\u003e\n\u003ctd data-start=\"2306\" data-end=\"2381\" data-col-size=\"md\"\u003e1.3 % (Class 1.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2382\" data-end=\"2482\"\u003e\n\u003ctd data-start=\"2382\" data-end=\"2411\" data-col-size=\"sm\"\u003eCore size \/ Inner diameter\u003c\/td\u003e\n\u003ctd data-start=\"2411\" data-end=\"2482\" data-col-size=\"md\"\u003e24 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2483\" data-end=\"2585\"\u003e\n\u003ctd data-start=\"2483\" data-end=\"2510\" data-col-size=\"sm\"\u003eOutput ratio\u003c\/td\u003e\n\u003ctd data-start=\"2510\" data-end=\"2585\" data-col-size=\"md\"\u003e50\/5 A = 10:1 ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2586\" data-end=\"2687\"\u003e\n\u003ctd data-start=\"2586\" data-end=\"2612\" data-col-size=\"sm\"\u003eType\u003c\/td\u003e\n\u003ctd data-start=\"2612\" data-end=\"2687\" data-col-size=\"md\"\u003eClamp\/split core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2688\" data-end=\"2789\"\u003e\n\u003ctd data-start=\"2688\" data-end=\"2715\" data-col-size=\"sm\"\u003eInsulation \/ housing\u003c\/td\u003e\n\u003ctd data-start=\"2715\" data-end=\"2789\" data-col-size=\"md\"\u003eFlame retardant plastic; protected against moisture; isolation rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2790\" data-end=\"2892\"\u003e\n\u003ctd data-start=\"2790\" data-end=\"2817\" data-col-size=\"sm\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-start=\"2817\" data-end=\"2892\" data-col-size=\"md\"\u003eClamp-around conductor; self-locking cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2893\" data-end=\"2995\"\u003e\n\u003ctd data-start=\"2893\" data-end=\"2920\" data-col-size=\"sm\"\u003eMaintenance\u003c\/td\u003e\n\u003ctd data-start=\"2920\" data-end=\"2995\" data-col-size=\"md\"\u003eMinimal; standard safety precautions apply when installing and using\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2997\" data-end=\"3000\"\u003e\n\u003ch3 data-start=\"3002\" data-end=\"3018\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"3020\" data-end=\"3363\"\u003e\n\u003cli data-start=\"3020\" data-end=\"3078\"\u003e\n\u003cp data-start=\"3022\" data-end=\"3078\"\u003eEnergy monitoring and metering in panels, switchboards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3079\" data-end=\"3175\"\u003e\n\u003cp data-start=\"3081\" data-end=\"3175\"\u003eProtection circuits (where Class 1.3 is acceptable) — e.g. overload trip, general indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3176\" data-end=\"3288\"\u003e\n\u003cp data-start=\"3178\" data-end=\"3288\"\u003eIndustrial or commercial installations with retrofit or additions, where opening the circuit is inconvenient\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3289\" data-end=\"3363\"\u003e\n\u003cp data-start=\"3291\" data-end=\"3363\"\u003eIntegration with panel meters, power analyzers, PLCs, or SCADA systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3365\" data-end=\"3368\"\u003e\n\u003ch3 data-start=\"3370\" data-end=\"3400\"\u003eInstallation \u0026amp; Usage Notes\u003c\/h3\u003e\n\u003cul data-start=\"3402\" data-end=\"3894\"\u003e\n\u003cli data-start=\"3402\" data-end=\"3507\"\u003e\n\u003cp data-start=\"3404\" data-end=\"3507\"\u003eEnsure that the conductor to be measured fits comfortably into the 24 mm opening without deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3508\" data-end=\"3671\"\u003e\n\u003cp data-start=\"3510\" data-end=\"3671\"\u003eSecondary output must not be open‐circuited while the transformer is energized — always have the secondary terminated in a load (meter, burden resistor, etc.).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3672\" data-end=\"3800\"\u003e\n\u003cp data-start=\"3674\" data-end=\"3800\"\u003eInstall in a location where environmental conditions (temperature, humidity, vibration) comply with the CT’s specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3801\" data-end=\"3894\"\u003e\n\u003cp data-start=\"3803\" data-end=\"3894\"\u003eUse proper insulation \/ cable protection to prevent damage to wires or the clamp housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3896\" data-end=\"3899\"\u003e\n\u003ch3 data-start=\"3901\" data-end=\"3924\"\u003eSafety \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul data-start=\"3926\" data-end=\"4277\"\u003e\n\u003cli data-start=\"3926\" data-end=\"4064\"\u003e\n\u003cp data-start=\"3928\" data-end=\"4064\"\u003eAdheres to split-core CT safety norms for insulation and fire resistance (plastic housing, etc.) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4065\" data-end=\"4189\"\u003e\n\u003cp data-start=\"4067\" data-end=\"4189\"\u003eClass 1.3 accuracy is suitable for general metering \/ control but not precision billing (unless local regulation allows)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4190\" data-end=\"4277\"\u003e\n\u003cp data-start=\"4192\" data-end=\"4277\"\u003eSecondary must always be loaded; never leave open‐circuit when primary is energised\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4279\" data-end=\"4282\"\u003e\n\u003ch3 data-start=\"4284\" data-end=\"4296\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"4298\" data-end=\"4543\"\u003e\n\u003cli data-start=\"4298\" data-end=\"4355\"\u003e\n\u003cp data-start=\"4300\" data-end=\"4355\"\u003eNon-invasive installation reduces downtime and labour\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4356\" data-end=\"4436\"\u003e\n\u003cp data-start=\"4358\" data-end=\"4436\"\u003eCompact design with inner diameter 24 mm fits many typical conductors easily\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4437\" data-end=\"4496\"\u003e\n\u003cp data-start=\"4439\" data-end=\"4496\"\u003eDecent accuracy (1.3%) for many monitoring\/control uses\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4497\" data-end=\"4543\"\u003e\n\u003cp data-start=\"4499\" data-end=\"4543\"\u003eRobust build, minimal maintenance required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350689763619,"sku":null,"price":175.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/CTA5X100A5A_SPL.webp?v=1758398255"},{"product_id":"clamp-on-current-transformer-lmck-24-100-5a-accuracy-class-1-3-split-core-clamp","title":"Clamp-On Current Transformer LMCK-24 • 100\/5A • Accuracy Class 1.3 • Split-Core Clamp","description":"\u003ch2 data-start=\"336\" data-end=\"358\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"360\" data-end=\"374\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"375\" data-end=\"784\"\u003eThe \u003cstrong data-start=\"379\" data-end=\"416\"\u003eLMCK-24 100\/5A Accuracy Class 1.3\u003c\/strong\u003e is a split-core (clamp-on) current transformer designed for easy, safe measurement of AC current in a live conductor without the need to disconnect wiring. With a primary current rating of 100 A and a secondary output of 5 A, this CT is suitable for energy monitoring, protection and measurement functions in industrial, commercial, or residential electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"786\" data-end=\"789\"\u003e\n\u003ch3 data-start=\"791\" data-end=\"807\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"809\" data-end=\"1582\"\u003e\n\u003cli data-start=\"809\" data-end=\"831\"\u003e\n\u003cp data-start=\"811\" data-end=\"831\"\u003e\u003cstrong data-start=\"811\" data-end=\"820\"\u003eModel\u003c\/strong\u003e: LMCK-24\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"832\" data-end=\"865\"\u003e\n\u003cp data-start=\"834\" data-end=\"865\"\u003e\u003cstrong data-start=\"834\" data-end=\"853\"\u003ePrimary Current\u003c\/strong\u003e: 100 A AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"866\" data-end=\"913\"\u003e\n\u003cp data-start=\"868\" data-end=\"913\"\u003e\u003cstrong data-start=\"868\" data-end=\"889\"\u003eSecondary Current\u003c\/strong\u003e: 5 A AC — ratio 100:5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"914\" data-end=\"996\"\u003e\n\u003cp data-start=\"916\" data-end=\"996\"\u003e\u003cstrong data-start=\"916\" data-end=\"934\"\u003eAccuracy Class\u003c\/strong\u003e: 1.3 (C1.3), meaning ±1.3% error under specified conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"997\" data-end=\"1120\"\u003e\n\u003cp data-start=\"999\" data-end=\"1120\"\u003e\u003cstrong data-start=\"999\" data-end=\"1007\"\u003eType\u003c\/strong\u003e: Split-core \/ clamp-on transformer — allows installation around conductors without having to break the circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1121\" data-end=\"1310\"\u003e\n\u003cp data-start=\"1123\" data-end=\"1310\"\u003e\u003cstrong data-start=\"1123\" data-end=\"1151\"\u003eWindow\/Core opening size\u003c\/strong\u003e: (if same as LMCK-24 standard) ~24 mm inner diameter (depends on variant) — large enough for many typical cable sizes. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1311\" data-end=\"1460\"\u003e\n\u003cp data-start=\"1313\" data-end=\"1460\"\u003e\u003cstrong data-start=\"1313\" data-end=\"1324\"\u003eHousing\u003c\/strong\u003e: Flame retardant plastic, moisture protected; stable performance, minimal maintenance required. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1461\" data-end=\"1582\"\u003e\n\u003cp data-start=\"1463\" data-end=\"1582\"\u003e\u003cstrong data-start=\"1463\" data-end=\"1495\"\u003eSelf-locking clamp mechanism\u003c\/strong\u003e: Easy and safe installation around conductors. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1584\" data-end=\"1587\"\u003e\n\u003ch3 data-start=\"1589\" data-end=\"1617\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1619\" data-end=\"2478\" class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 100.036%; height: 313.6px;\"\u003e\n\u003cthead data-start=\"1619\" data-end=\"1645\"\u003e\n\u003ctr data-start=\"1619\" data-end=\"1645\" style=\"height: 19.6px;\"\u003e\n\u003cth data-start=\"1619\" data-end=\"1635\" data-col-size=\"md\" style=\"width: 28.1595%; height: 19.6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1635\" data-end=\"1645\" data-col-size=\"lg\" style=\"width: 69.3806%; height: 19.6px;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1674\" data-end=\"2478\"\u003e\n\u003ctr data-start=\"1674\" data-end=\"1711\" style=\"height: 19.6px;\"\u003e\n\u003ctd data-start=\"1674\" data-end=\"1699\" data-col-size=\"md\" style=\"width: 28.1595%; height: 19.6px;\"\u003ePrimary current rating\u003c\/td\u003e\n\u003ctd data-start=\"1699\" data-end=\"1711\" data-col-size=\"lg\" style=\"width: 69.3806%; height: 19.6px;\"\u003e100 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1712\" data-end=\"1749\" style=\"height: 19.6px;\"\u003e\n\u003ctd data-start=\"1712\" data-end=\"1739\" data-col-size=\"md\" style=\"width: 28.1595%; height: 19.6px;\"\u003eSecondary current rating\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"1739\" data-end=\"1749\" style=\"width: 69.3806%; height: 19.6px;\"\u003e5 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1750\" data-end=\"1782\" style=\"height: 19.6px;\"\u003e\n\u003ctd data-start=\"1750\" data-end=\"1773\" data-col-size=\"md\" style=\"width: 28.1595%; height: 19.6px;\"\u003eTransformation ratio\u003c\/td\u003e\n\u003ctd data-start=\"1773\" data-end=\"1782\" data-col-size=\"lg\" style=\"width: 69.3806%; height: 19.6px;\"\u003e100:5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1783\" data-end=\"1820\" style=\"height: 19.6px;\"\u003e\n\u003ctd data-start=\"1783\" data-end=\"1800\" data-col-size=\"md\" style=\"width: 28.1595%; height: 19.6px;\"\u003eAccuracy class\u003c\/td\u003e\n\u003ctd data-start=\"1800\" data-end=\"1820\" data-col-size=\"lg\" style=\"width: 69.3806%; height: 19.6px;\"\u003e1.3 (Class C1.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1821\" data-end=\"1935\" style=\"height: 39.2px;\"\u003e\n\u003ctd data-start=\"1821\" data-end=\"1842\" data-col-size=\"md\" style=\"width: 28.1595%; height: 39.2px;\"\u003eCore \/ window size\u003c\/td\u003e\n\u003ctd data-start=\"1842\" data-end=\"1935\" data-col-size=\"lg\" style=\"width: 69.3806%; height: 39.2px;\"\u003e~24 mm opening (depending on exact LMCK-24 version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1936\" data-end=\"2070\" style=\"height: 39.2px;\"\u003e\n\u003ctd data-start=\"1936\" data-end=\"1958\" data-col-size=\"md\" style=\"width: 28.1595%; height: 39.2px;\"\u003eHousing \/ Enclosure\u003c\/td\u003e\n\u003ctd data-start=\"1958\" data-end=\"2070\" data-col-size=\"lg\" style=\"width: 69.3806%; height: 39.2px;\"\u003eFlame-retardant plastic; moisture protected; self-locking clamp design \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2071\" data-end=\"2157\" style=\"height: 39.2px;\"\u003e\n\u003ctd data-start=\"2071\" data-end=\"2104\" data-col-size=\"md\" style=\"width: 28.1595%; height: 39.2px;\"\u003eBurden (max load on secondary)\u003c\/td\u003e\n\u003ctd data-start=\"2104\" data-end=\"2157\" data-col-size=\"lg\" style=\"width: 69.3806%; height: 39.2px;\"\u003e\u003cem data-start=\"2106\" data-end=\"2155\"\u003eTo be specified by manufacturer or in datasheet\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2158\" data-end=\"2362\" style=\"height: 58.8px;\"\u003e\n\u003ctd data-start=\"2158\" data-end=\"2180\" data-col-size=\"md\" style=\"width: 28.1595%; height: 58.8px;\"\u003eSafety \/ insulation\u003c\/td\u003e\n\u003ctd data-start=\"2180\" data-end=\"2362\" data-col-size=\"lg\" style=\"width: 69.3806%; height: 58.8px;\"\u003ePlastic case conforms to standard requirements; safe handling recommended; secondary must not be left open circuit when primary is energized \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2363\" data-end=\"2478\" style=\"height: 39.2px;\"\u003e\n\u003ctd data-start=\"2363\" data-end=\"2410\" data-col-size=\"md\" style=\"width: 28.1595%; height: 39.2px;\"\u003eOperating temperature \/ environmental limits\u003c\/td\u003e\n\u003ctd data-start=\"2410\" data-end=\"2478\" data-col-size=\"lg\" style=\"width: 69.3806%; height: 39.2px;\"\u003e\u003cem data-start=\"2412\" data-end=\"2476\"\u003eTo be specified by the manufacturer (e.g. −20°C to +70°C etc.)\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2480\" data-end=\"2483\"\u003e\n\u003ch3 data-start=\"2485\" data-end=\"2501\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2503\" data-end=\"2812\"\u003e\n\u003cli data-start=\"2503\" data-end=\"2583\"\u003e\n\u003cp data-start=\"2505\" data-end=\"2583\"\u003eEnergy and power monitoring in switchboards, panels, and distribution boards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2584\" data-end=\"2657\"\u003e\n\u003cp data-start=\"2586\" data-end=\"2657\"\u003eFeed into meters or monitoring devices (PLCs, SCADA, power analyzers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2658\" data-end=\"2744\"\u003e\n\u003cp data-start=\"2660\" data-end=\"2744\"\u003eRetrofitting existing circuits where opening the primary conductor is inconvenient\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2745\" data-end=\"2812\"\u003e\n\u003cp data-start=\"2747\" data-end=\"2812\"\u003eGeneral protection, current over-load detection, load balancing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2814\" data-end=\"2817\"\u003e\n\u003ch3 data-start=\"2819\" data-end=\"2847\"\u003eInstallation \u0026amp; Use Notes\u003c\/h3\u003e\n\u003cul data-start=\"2849\" data-end=\"3395\"\u003e\n\u003cli data-start=\"2849\" data-end=\"2952\"\u003e\n\u003cp data-start=\"2851\" data-end=\"2952\"\u003eEnsure the conductor to be measured fits through the clamp opening comfortably without deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2953\" data-end=\"3124\"\u003e\n\u003cp data-start=\"2955\" data-end=\"3124\"\u003eDo \u003cstrong data-start=\"2958\" data-end=\"2970\"\u003enot open\u003c\/strong\u003e the secondary circuit when the primary is energized. Always connect the secondary to a load (meter, burden resistor, etc.) to avoid dangerous voltages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3125\" data-end=\"3192\"\u003e\n\u003cp data-start=\"3127\" data-end=\"3192\"\u003eMount the CT securely; ensure clamp is fully closed and locked.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3193\" data-end=\"3330\"\u003e\n\u003cp data-start=\"3195\" data-end=\"3330\"\u003eMinimize external magnetic interference: avoid placing near large magnetic fields or heavy electromagnetic equipment unless shielded.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3331\" data-end=\"3395\"\u003e\n\u003cp data-start=\"3333\" data-end=\"3395\"\u003eEnsure compliance with local electrical codes and standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3397\" data-end=\"3400\"\u003e\n\u003ch3 data-start=\"3402\" data-end=\"3414\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"3416\" data-end=\"3629\"\u003e\n\u003cli data-start=\"3416\" data-end=\"3479\"\u003e\n\u003cp data-start=\"3418\" data-end=\"3479\"\u003eNon-intrusive installation reduces downtime and labour cost\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3480\" data-end=\"3534\"\u003e\n\u003cp data-start=\"3482\" data-end=\"3534\"\u003eReliable measurements thanks to accuracy class 1.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3535\" data-end=\"3580\"\u003e\n\u003cp data-start=\"3537\" data-end=\"3580\"\u003eDurable build, minimal maintenance needed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3581\" data-end=\"3629\"\u003e\n\u003cp data-start=\"3583\" data-end=\"3629\"\u003eSuitable for many standard measurement tasks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350693695779,"sku":null,"price":180.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/split-core-CT.webp?v=1758398255"},{"product_id":"clamp-current-transformer-lmck-24-200-5a-accuracy-class-1-split-core-clamp-on","title":"Clamp Current Transformer LMCK-24 • 200\/5A • Accuracy Class 1 • Split-Core \/ Clamp-On","description":"\u003ch2 data-start=\"373\" data-end=\"395\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"397\" data-end=\"411\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"412\" data-end=\"793\"\u003eThe \u003cstrong data-start=\"416\" data-end=\"451\"\u003eLMCK-24 200\/5A Accuracy Class 1\u003c\/strong\u003e is a clamp-on (split-core) current transformer from the LMCK series, designed for accurate measurement of alternating current (AC) in electrical circuits. With a primary rating of 200 A and secondary of 5 A, this CT provides reliable current monitoring for industrial, commercial, or residential systems where a Class 1 accuracy is required.\u003c\/p\u003e\n\u003chr data-start=\"795\" data-end=\"798\"\u003e\n\u003ch3 data-start=\"800\" data-end=\"816\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"818\" data-end=\"1673\"\u003e\n\u003cli data-start=\"818\" data-end=\"840\"\u003e\n\u003cp data-start=\"820\" data-end=\"840\"\u003e\u003cstrong data-start=\"820\" data-end=\"829\"\u003eModel\u003c\/strong\u003e: LMCK-24\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"841\" data-end=\"881\"\u003e\n\u003cp data-start=\"843\" data-end=\"881\"\u003e\u003cstrong data-start=\"843\" data-end=\"869\"\u003ePrimary Current Rating\u003c\/strong\u003e: 200 A AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"882\" data-end=\"948\"\u003e\n\u003cp data-start=\"884\" data-end=\"948\"\u003e\u003cstrong data-start=\"884\" data-end=\"912\"\u003eSecondary Current Rating\u003c\/strong\u003e: 5 A AC — giving a ratio of 200:5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"949\" data-end=\"1061\"\u003e\n\u003cp data-start=\"951\" data-end=\"1061\"\u003e\u003cstrong data-start=\"951\" data-end=\"969\"\u003eAccuracy Class\u003c\/strong\u003e: \u003cstrong data-start=\"971\" data-end=\"978\"\u003e1.0\u003c\/strong\u003e — meaning it will have a maximum permissible error of ±1% under rated conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1062\" data-end=\"1175\"\u003e\n\u003cp data-start=\"1064\" data-end=\"1175\"\u003e\u003cstrong data-start=\"1064\" data-end=\"1074\"\u003eDesign\u003c\/strong\u003e: Split-core \/ clamp-on — easy installation around existing conductors without breaking the circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1176\" data-end=\"1378\"\u003e\n\u003cp data-start=\"1178\" data-end=\"1378\"\u003e\u003cstrong data-start=\"1178\" data-end=\"1201\"\u003eCore \/ Opening Size\u003c\/strong\u003e: Approx. 24 mm inner aperture (same “24” in LMCK-24 series suggests ~24 mm window) based on similar models from LMCK split-core CT line. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1379\" data-end=\"1531\"\u003e\n\u003cp data-start=\"1381\" data-end=\"1531\"\u003e\u003cstrong data-start=\"1381\" data-end=\"1392\"\u003eHousing\u003c\/strong\u003e: Flame-retardant plastic, moisture-protected, stable in performance, requires minimal maintenance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1532\" data-end=\"1673\"\u003e\n\u003cp data-start=\"1534\" data-end=\"1673\"\u003e\u003cstrong data-start=\"1534\" data-end=\"1556\"\u003eSelf-locking clamp\u003c\/strong\u003e: Facilitates safe, secure installation; portable and suitable for retrofits. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1675\" data-end=\"1678\"\u003e\n\u003ch3 data-start=\"1680\" data-end=\"1708\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1710\" data-end=\"2452\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1710\" data-end=\"1752\"\u003e\n\u003ctr data-start=\"1710\" data-end=\"1752\"\u003e\n\u003cth data-start=\"1710\" data-end=\"1726\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1726\" data-end=\"1752\" data-col-size=\"md\"\u003eDetail \/ Typical Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1798\" data-end=\"2452\"\u003e\n\u003ctr data-start=\"1798\" data-end=\"1833\"\u003e\n\u003ctd data-start=\"1798\" data-end=\"1821\" data-col-size=\"sm\"\u003ePrimary Current (In)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1821\" data-end=\"1833\"\u003e200 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1834\" data-end=\"1869\"\u003e\n\u003ctd data-start=\"1834\" data-end=\"1859\" data-col-size=\"sm\"\u003eSecondary Current (Is)\u003c\/td\u003e\n\u003ctd data-start=\"1859\" data-end=\"1869\" data-col-size=\"md\"\u003e5 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1870\" data-end=\"1902\"\u003e\n\u003ctd data-start=\"1870\" data-end=\"1893\" data-col-size=\"sm\"\u003eTransformation Ratio\u003c\/td\u003e\n\u003ctd data-start=\"1893\" data-end=\"1902\" data-col-size=\"md\"\u003e200:5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1903\" data-end=\"1927\"\u003e\n\u003ctd data-start=\"1903\" data-end=\"1920\" data-col-size=\"sm\"\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd data-start=\"1920\" data-end=\"1927\" data-col-size=\"md\"\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1928\" data-end=\"1980\"\u003e\n\u003ctd data-start=\"1928\" data-end=\"1954\" data-col-size=\"sm\"\u003eInner Diameter \/ Window\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1954\" data-end=\"1980\"\u003e~24 mm (for conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1981\" data-end=\"2011\"\u003e\n\u003ctd data-start=\"1981\" data-end=\"1988\" data-col-size=\"sm\"\u003eType\u003c\/td\u003e\n\u003ctd data-start=\"1988\" data-end=\"2011\" data-col-size=\"md\"\u003eSplit-core clamp-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2012\" data-end=\"2084\"\u003e\n\u003ctd data-start=\"2012\" data-end=\"2031\" data-col-size=\"sm\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd data-start=\"2031\" data-end=\"2084\" data-col-size=\"md\"\u003eFlame retardant plastic (UL-94 V-0 or equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2085\" data-end=\"2173\"\u003e\n\u003ctd data-start=\"2085\" data-end=\"2110\" data-col-size=\"sm\"\u003eProtection \/ Enclosure\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2110\" data-end=\"2173\"\u003eMoisture protected; rated for indoor electrical environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2174\" data-end=\"2243\"\u003e\n\u003ctd data-start=\"2174\" data-end=\"2196\" data-col-size=\"sm\"\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd data-start=\"2196\" data-end=\"2243\" data-col-size=\"md\"\u003eTypically 50\/60 Hz (confirm with datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2244\" data-end=\"2336\"\u003e\n\u003ctd data-start=\"2244\" data-end=\"2260\" data-col-size=\"sm\"\u003eBurden \/ Load\u003c\/td\u003e\n\u003ctd data-start=\"2260\" data-end=\"2336\" data-col-size=\"md\"\u003eTo be specified (manufacturer will supply maximum VA load for secondary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2337\" data-end=\"2452\"\u003e\n\u003ctd data-start=\"2337\" data-end=\"2352\" data-col-size=\"sm\"\u003eSafety Notes\u003c\/td\u003e\n\u003ctd data-start=\"2352\" data-end=\"2452\" data-col-size=\"md\"\u003eSecondary must not be open circuit when primary energized; ensure proper insulation and mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2454\" data-end=\"2457\"\u003e\n\u003ch3 data-start=\"2459\" data-end=\"2475\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2477\" data-end=\"2830\"\u003e\n\u003cli data-start=\"2477\" data-end=\"2560\"\u003e\n\u003cp data-start=\"2479\" data-end=\"2560\"\u003eEnergy monitoring and metering in switchboards, panels, and distribution boards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2561\" data-end=\"2647\"\u003e\n\u003cp data-start=\"2563\" data-end=\"2647\"\u003eRetrofitting or adding measurement to existing circuits without power interruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2648\" data-end=\"2724\"\u003e\n\u003cp data-start=\"2650\" data-end=\"2724\"\u003eUse with power meters, PLCs, monitoring \u0026amp; control systems, SCADA systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2725\" data-end=\"2830\"\u003e\n\u003cp data-start=\"2727\" data-end=\"2830\"\u003eMonitoring of motors, lighting, HVAC, and other electrical loads where accuracy class 1 is sufficient\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2832\" data-end=\"2835\"\u003e\n\u003ch3 data-start=\"2837\" data-end=\"2873\"\u003eInstallation \u0026amp; Safety Guidelines\u003c\/h3\u003e\n\u003cul data-start=\"2875\" data-end=\"3392\"\u003e\n\u003cli data-start=\"2875\" data-end=\"2988\"\u003e\n\u003cp data-start=\"2877\" data-end=\"2988\"\u003eVerify that conductor fits comfortably through ~24 mm opening; avoid forcing or bending conductor unnaturally\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2989\" data-end=\"3153\"\u003e\n\u003cp data-start=\"2991\" data-end=\"3153\"\u003eAlways ensure secondary is terminated (connected to meter \/ load); never leave secondary open during operation—this can lead to dangerous overvoltage and damage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3154\" data-end=\"3205\"\u003e\n\u003cp data-start=\"3156\" data-end=\"3205\"\u003eMount securely; close and lock clamp completely\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3206\" data-end=\"3319\"\u003e\n\u003cp data-start=\"3208\" data-end=\"3319\"\u003eAvoid installing in high ambient temperature beyond spec, very humid or corrosive environments (unless rated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3320\" data-end=\"3392\"\u003e\n\u003cp data-start=\"3322\" data-end=\"3392\"\u003eUse proper wire \/ cable protection at the entry points to avoid wear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3394\" data-end=\"3397\"\u003e\n\u003ch3 data-start=\"3399\" data-end=\"3411\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"3413\" data-end=\"3715\"\u003e\n\u003cli data-start=\"3413\" data-end=\"3491\"\u003e\n\u003cp data-start=\"3415\" data-end=\"3491\"\u003eNon-intrusive installation saves labour and risk (no disconnection needed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3492\" data-end=\"3606\"\u003e\n\u003cp data-start=\"3494\" data-end=\"3606\"\u003eClass-1 accuracy gives reliable readings for general metering \/ billing where higher precision isn’t necessary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3607\" data-end=\"3659\"\u003e\n\u003cp data-start=\"3609\" data-end=\"3659\"\u003eDurable, low maintenance, consistent performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3660\" data-end=\"3715\"\u003e\n\u003cp data-start=\"3662\" data-end=\"3715\"\u003eWidely compatible with standard measurement devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350699561251,"sku":null,"price":200.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/rayleigh_instruments_ri-cts036_alternergy_1_1.jpg?v=1758398256"},{"product_id":"clamp-split-core-current-transformer-lmck-24-250-5a-accuracy-class-1","title":"Clamp\/Split-Core Current Transformer LMCK-24 • 250\/5A • Accuracy Class 1","description":"\u003ch2 data-start=\"376\" data-end=\"398\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"400\" data-end=\"414\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"415\" data-end=\"822\"\u003eThe \u003cstrong data-start=\"419\" data-end=\"454\"\u003eLMCK-24 250\/5A Accuracy Class 1\u003c\/strong\u003e is a high-capacity, clamp-on (split-core) current transformer designed for general metering, monitoring, and protection applications where 250 A primary current must be converted to 5 A secondary current. With a Class 1 accuracy, it offers ±1% error under rated conditions, making it suitable for many industrial, commercial, and residential energy measurement tasks.\u003c\/p\u003e\n\u003chr data-start=\"824\" data-end=\"827\"\u003e\n\u003ch3 data-start=\"829\" data-end=\"845\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"847\" data-end=\"1719\"\u003e\n\u003cli data-start=\"847\" data-end=\"958\"\u003e\n\u003cp data-start=\"849\" data-end=\"958\"\u003eBrand \/ Series: LMCK-24 (Zhikai) – split-core type with clamp design. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"959\" data-end=\"1030\"\u003e\n\u003cp data-start=\"961\" data-end=\"1030\"\u003ePrimary Current: \u003cstrong data-start=\"978\" data-end=\"990\"\u003e250 A AC\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1031\" data-end=\"1102\"\u003e\n\u003cp data-start=\"1033\" data-end=\"1102\"\u003eSecondary Current: \u003cstrong data-start=\"1052\" data-end=\"1062\"\u003e5 A AC\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1103\" data-end=\"1296\"\u003e\n\u003cp data-start=\"1105\" data-end=\"1296\"\u003eAccuracy: \u003cstrong data-start=\"1115\" data-end=\"1126\"\u003eClass 1\u003c\/strong\u003e (1.0%) — good for general-level metering and monitoring. (Note: Zhikai offers different accuracy classes; confirm with supplier.) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1297\" data-end=\"1440\"\u003e\n\u003cp data-start=\"1299\" data-end=\"1440\"\u003eInner Window \/ Diameter: ~ \u003cstrong data-start=\"1326\" data-end=\"1335\"\u003e24 mm\u003c\/strong\u003e for the LMCK-24 variant — fits typical cable or conductor sizes. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1441\" data-end=\"1582\"\u003e\n\u003cp data-start=\"1443\" data-end=\"1582\"\u003eHousing: Flame retardant plastic, moisture protected; stable over time; minimal maintenance needed. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1583\" data-end=\"1719\"\u003e\n\u003cp data-start=\"1585\" data-end=\"1719\"\u003eSelf-locking clamp mechanism for easy installation without interrupting the primary conductor. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1721\" data-end=\"1724\"\u003e\n\u003ch3 data-start=\"1726\" data-end=\"1754\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1756\" data-end=\"2305\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1756\" data-end=\"1782\"\u003e\n\u003ctr data-start=\"1756\" data-end=\"1782\"\u003e\n\u003cth data-start=\"1756\" data-end=\"1772\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1772\" data-end=\"1782\" data-col-size=\"md\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1811\" data-end=\"2305\"\u003e\n\u003ctr data-start=\"1811\" data-end=\"1853\"\u003e\n\u003ctd data-start=\"1811\" data-end=\"1841\" data-col-size=\"sm\"\u003ePrimary current rating (In)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1841\" data-end=\"1853\"\u003e250 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1854\" data-end=\"1896\"\u003e\n\u003ctd data-start=\"1854\" data-end=\"1886\" data-col-size=\"sm\"\u003eSecondary current rating (Is)\u003c\/td\u003e\n\u003ctd data-start=\"1886\" data-end=\"1896\" data-col-size=\"md\"\u003e5 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1897\" data-end=\"1929\"\u003e\n\u003ctd data-start=\"1897\" data-end=\"1920\" data-col-size=\"sm\"\u003eTransformation ratio\u003c\/td\u003e\n\u003ctd data-start=\"1920\" data-end=\"1929\" data-col-size=\"md\"\u003e250:5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1930\" data-end=\"1960\"\u003e\n\u003ctd data-start=\"1930\" data-end=\"1947\" data-col-size=\"sm\"\u003eAccuracy class\u003c\/td\u003e\n\u003ctd data-start=\"1947\" data-end=\"1960\" data-col-size=\"md\"\u003e1.0 (±1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1961\" data-end=\"2015\"\u003e\n\u003ctd data-start=\"1961\" data-end=\"1995\" data-col-size=\"sm\"\u003eInner diameter \/ window opening\u003c\/td\u003e\n\u003ctd data-start=\"1995\" data-end=\"2015\" data-col-size=\"md\"\u003e~24 mm (LMCK-24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2016\" data-end=\"2082\"\u003e\n\u003ctd data-start=\"2016\" data-end=\"2035\" data-col-size=\"sm\"\u003eHousing material\u003c\/td\u003e\n\u003ctd data-start=\"2035\" data-end=\"2082\" data-col-size=\"md\"\u003eFlame retardant plastic, moisture protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2083\" data-end=\"2122\"\u003e\n\u003ctd data-start=\"2083\" data-end=\"2099\" data-col-size=\"sm\"\u003eMounting type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2099\" data-end=\"2122\"\u003eSplit-core clamp-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2123\" data-end=\"2190\"\u003e\n\u003ctd data-start=\"2123\" data-end=\"2141\" data-col-size=\"sm\"\u003eRated frequency\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2141\" data-end=\"2190\"\u003eTypically 50 \/ 60 Hz (confirm with datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2191\" data-end=\"2305\"\u003e\n\u003ctd data-start=\"2191\" data-end=\"2205\" data-col-size=\"sm\"\u003eKey caution\u003c\/td\u003e\n\u003ctd data-start=\"2205\" data-end=\"2305\" data-col-size=\"md\"\u003eNever leave the secondary open when the primary is energized – always have burden\/load connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2307\" data-end=\"2310\"\u003e\n\u003ch3 data-start=\"2312\" data-end=\"2328\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2330\" data-end=\"2634\"\u003e\n\u003cli data-start=\"2330\" data-end=\"2408\"\u003e\n\u003cp data-start=\"2332\" data-end=\"2408\"\u003eEnergy \/ power monitoring in panels, switchboards, and distribution boards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2409\" data-end=\"2514\"\u003e\n\u003cp data-start=\"2411\" data-end=\"2514\"\u003eLoad monitoring, consumption tracking, and general metering in industrial or commercial installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2515\" data-end=\"2581\"\u003e\n\u003cp data-start=\"2517\" data-end=\"2581\"\u003eRetrofit installations where the circuit cannot be interrupted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2582\" data-end=\"2634\"\u003e\n\u003cp data-start=\"2584\" data-end=\"2634\"\u003eUse with power meters, PLCs, SCADA systems, etc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2636\" data-end=\"2639\"\u003e\n\u003ch3 data-start=\"2641\" data-end=\"2672\"\u003eInstallation \u0026amp; Safety Notes\u003c\/h3\u003e\n\u003cul data-start=\"2674\" data-end=\"3216\"\u003e\n\u003cli data-start=\"2674\" data-end=\"2789\"\u003e\n\u003cp data-start=\"2676\" data-end=\"2789\"\u003eMake sure the conductor to be measured passes cleanly through the ~24 mm opening without strain or deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2790\" data-end=\"2980\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2980\"\u003eThe secondary winding must always be terminated (connected to measurement device or load) when the primary is carrying current — an open-circuit secondary can lead to dangerous voltages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2981\" data-end=\"3052\"\u003e\n\u003cp data-start=\"2983\" data-end=\"3052\"\u003eSecure clamp fully closed, ensure stable mounting, avoid vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3053\" data-end=\"3146\"\u003e\n\u003cp data-start=\"3055\" data-end=\"3146\"\u003eKeep the housing clean and away from extreme temperature or moisture beyond rated limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3147\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3149\" data-end=\"3216\"\u003eCheck local electrical codes \/ safety standards for installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3218\" data-end=\"3221\"\u003e\n\u003ch3 data-start=\"3223\" data-end=\"3235\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"3237\" data-end=\"3465\"\u003e\n\u003cli data-start=\"3237\" data-end=\"3305\"\u003e\n\u003cp data-start=\"3239\" data-end=\"3305\"\u003eAllows measurement without disrupting existing wiring (clamp-on)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3306\" data-end=\"3364\"\u003e\n\u003cp data-start=\"3308\" data-end=\"3364\"\u003eGood accuracy (Class 1) for many metering applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3365\" data-end=\"3400\"\u003e\n\u003cp data-start=\"3367\" data-end=\"3400\"\u003eDurable, low maintenance design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3401\" data-end=\"3465\"\u003e\n\u003cp data-start=\"3403\" data-end=\"3465\"\u003eCompatible with standard instrumentation (meters, analyzers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350710735139,"sku":null,"price":205.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/current-instrument-transformers-500x500.webp?v=1758398255"},{"product_id":"clamp-split-core-current-transformer-lmck-24-300-5a-accuracy-class-1","title":"Clamp \/ Split-Core Current Transformer LMCK-24 • 300\/5A • Accuracy Class 1","description":"\u003ch3 data-start=\"842\" data-end=\"857\"\u003eDescription\u003c\/h3\u003e\n\u003ch4 data-start=\"859\" data-end=\"874\"\u003eOverview\u003c\/h4\u003e\n\u003cp data-start=\"875\" data-end=\"1252\"\u003eThe \u003cstrong data-start=\"879\" data-end=\"914\"\u003eLMCK-24 300\/5A Accuracy Class 1\u003c\/strong\u003e is a high-rating split-core (clamp-on) current transformer, designed for precise AC current measurement. With a primary rating of 300 A and secondary of 5 A, this model delivers reliable and accurate readings (±1%) under standard operational conditions. It's ideal for retrofits and new installations where the wiring can’t be disrupted.\u003c\/p\u003e\n\u003chr data-start=\"1254\" data-end=\"1257\"\u003e\n\u003ch4 data-start=\"1259\" data-end=\"1276\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-start=\"1278\" data-end=\"2005\"\u003e\n\u003cli data-start=\"1278\" data-end=\"1311\"\u003e\n\u003cp data-start=\"1280\" data-end=\"1311\"\u003e\u003cstrong data-start=\"1280\" data-end=\"1299\"\u003ePrimary Current\u003c\/strong\u003e: 300 A AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1312\" data-end=\"1385\"\u003e\n\u003cp data-start=\"1314\" data-end=\"1385\"\u003e\u003cstrong data-start=\"1314\" data-end=\"1335\"\u003eSecondary Current\u003c\/strong\u003e: 5 A AC (output) — transformation ratio 300:5 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1386\" data-end=\"1463\"\u003e\n\u003cp data-start=\"1388\" data-end=\"1463\"\u003e\u003cstrong data-start=\"1388\" data-end=\"1406\"\u003eAccuracy Class\u003c\/strong\u003e: 1.0 (±1%) under rated conditions \/ on standard burden\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1464\" data-end=\"1623\"\u003e\n\u003cp data-start=\"1466\" data-end=\"1623\"\u003e\u003cstrong data-start=\"1466\" data-end=\"1493\"\u003eWindow \/ Inner Diameter\u003c\/strong\u003e: ~24 mm, suitable for many cables or busbars without tight bending or deformation limits. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1624\" data-end=\"1721\"\u003e\n\u003cp data-start=\"1626\" data-end=\"1721\"\u003e\u003cstrong data-start=\"1626\" data-end=\"1634\"\u003eType\u003c\/strong\u003e: Split‐core \/ clamp-on — allows installation without breaking the primary conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1722\" data-end=\"1869\"\u003e\n\u003cp data-start=\"1724\" data-end=\"1869\"\u003e\u003cstrong data-start=\"1724\" data-end=\"1735\"\u003eHousing\u003c\/strong\u003e: Flame-retardant plastic enclosure, moisture protection, stable performance; low maintenance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1870\" data-end=\"2005\"\u003e\n\u003cp data-start=\"1872\" data-end=\"2005\"\u003e\u003cstrong data-start=\"1872\" data-end=\"1888\"\u003eSafety Notes\u003c\/strong\u003e: Secondary winding must \u003cstrong data-start=\"1913\" data-end=\"1920\"\u003enot\u003c\/strong\u003e be open-circuited when primary is energized. Always use with meter or burden load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2007\" data-end=\"2010\"\u003e\n\u003ch3 data-start=\"2012\" data-end=\"2069\"\u003eAdditional Specifications (Typical \/ Where Available)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2071\" data-end=\"2811\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2071\" data-end=\"2106\"\u003e\n\u003ctr data-start=\"2071\" data-end=\"2106\"\u003e\n\u003cth data-start=\"2071\" data-end=\"2087\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2087\" data-end=\"2106\" data-col-size=\"lg\"\u003eValue \/ Comment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2147\" data-end=\"2811\"\u003e\n\u003ctr data-start=\"2147\" data-end=\"2215\"\u003e\n\u003ctd data-start=\"2147\" data-end=\"2167\" data-col-size=\"sm\"\u003eInner Window Size\u003c\/td\u003e\n\u003ctd data-start=\"2167\" data-end=\"2215\" data-col-size=\"lg\"\u003e~24 mm \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2216\" data-end=\"2324\"\u003e\n\u003ctd data-start=\"2216\" data-end=\"2235\" data-col-size=\"sm\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd data-start=\"2235\" data-end=\"2324\" data-col-size=\"lg\"\u003eFlame-retardant plastic (UL94-V0 or equivalent) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2325\" data-end=\"2365\"\u003e\n\u003ctd data-start=\"2325\" data-end=\"2343\" data-col-size=\"sm\"\u003eRated Frequency\u003c\/td\u003e\n\u003ctd data-start=\"2343\" data-end=\"2365\" data-col-size=\"lg\"\u003e50\/60 Hz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2366\" data-end=\"2466\"\u003e\n\u003ctd data-start=\"2366\" data-end=\"2404\" data-col-size=\"sm\"\u003eEnvironmental \/ Moisture Protection\u003c\/td\u003e\n\u003ctd data-start=\"2404\" data-end=\"2466\" data-col-size=\"lg\"\u003eProtected from moisture; indoor use unless otherwise rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2467\" data-end=\"2565\"\u003e\n\u003ctd data-start=\"2467\" data-end=\"2485\" data-col-size=\"sm\"\u003eBurden \/ Max VA\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2485\" data-end=\"2565\"\u003e(To be confirmed by supplier; for many class-1 CTs burden of 1-2 VA or more)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2566\" data-end=\"2647\"\u003e\n\u003ctd data-start=\"2566\" data-end=\"2600\" data-col-size=\"sm\"\u003eOperating \/ Storage Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2600\" data-end=\"2647\" data-col-size=\"lg\"\u003eTo be confirmed (supplier datasheet needed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2648\" data-end=\"2811\"\u003e\n\u003ctd data-start=\"2648\" data-end=\"2673\" data-col-size=\"sm\"\u003eStandards \/ Compliance\u003c\/td\u003e\n\u003ctd data-start=\"2673\" data-end=\"2811\" data-col-size=\"lg\"\u003eFollows LMCK series norms; usually aligned with IEC or equivalent current transformer standards. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2813\" data-end=\"2816\"\u003e\n\u003ch3 data-start=\"2818\" data-end=\"2834\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2836\" data-end=\"3149\"\u003e\n\u003cli data-start=\"2836\" data-end=\"2925\"\u003e\n\u003cp data-start=\"2838\" data-end=\"2925\"\u003eMonitoring electrical load in switchboards, control panels, and distribution circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2926\" data-end=\"3015\"\u003e\n\u003cp data-start=\"2928\" data-end=\"3015\"\u003eIntegrating with energy meters, power analyzers, PLCs, or building management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3016\" data-end=\"3079\"\u003e\n\u003cp data-start=\"3018\" data-end=\"3079\"\u003eRetrofit projects where primary conductors remain energized\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3080\" data-end=\"3149\"\u003e\n\u003cp data-start=\"3082\" data-end=\"3149\"\u003eUse in industrial, commercial, or large residential installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3151\" data-end=\"3154\"\u003e\n\u003ch3 data-start=\"3156\" data-end=\"3187\"\u003eInstallation \u0026amp; Safety Notes\u003c\/h3\u003e\n\u003cul data-start=\"3189\" data-end=\"3596\"\u003e\n\u003cli data-start=\"3189\" data-end=\"3283\"\u003e\n\u003cp data-start=\"3191\" data-end=\"3283\"\u003eMake sure the conductor or busbar fits cleanly into the ~24 mm window without deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3284\" data-end=\"3406\"\u003e\n\u003cp data-start=\"3286\" data-end=\"3406\"\u003eNever leave the secondary side open circuit when primary is carrying current — always connect to meter or burden load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3407\" data-end=\"3478\"\u003e\n\u003cp data-start=\"3409\" data-end=\"3478\"\u003eSecure the clamp \/ split core properly; ensure good mechanical fit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3479\" data-end=\"3542\"\u003e\n\u003cp data-start=\"3481\" data-end=\"3542\"\u003eAvoid placing near sources of strong magnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3543\" data-end=\"3596\"\u003e\n\u003cp data-start=\"3545\" data-end=\"3596\"\u003eFollow local electrical safety \/ grounding codes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3598\" data-end=\"3601\"\u003e\n\u003ch3 data-start=\"3603\" data-end=\"3615\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"3617\" data-end=\"3858\"\u003e\n\u003cli data-start=\"3617\" data-end=\"3679\"\u003e\n\u003cp data-start=\"3619\" data-end=\"3679\"\u003eAccurate (Class 1) readings for many measurement use cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3680\" data-end=\"3765\"\u003e\n\u003cp data-start=\"3682\" data-end=\"3765\"\u003eNon-intrusive installation saves time — no need to disconnect the primary circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3766\" data-end=\"3807\"\u003e\n\u003cp data-start=\"3768\" data-end=\"3807\"\u003eDurable, stable, with low maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3808\" data-end=\"3858\"\u003e\n\u003cp data-start=\"3810\" data-end=\"3858\"\u003eCompatible with standard 5 A secondary devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350712144163,"sku":null,"price":210.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/CTA5X100A5A_SPL.webp?v=1758398255"},{"product_id":"clamp-split-core-current-transformer-lmck-24-400-5a-accuracy-class-0-5","title":"Clamp \/ Split-Core Current Transformer LMCK-24 • 400\/5A • Accuracy Class 0.5","description":"\u003ch2 data-start=\"808\" data-end=\"830\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"832\" data-end=\"846\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"847\" data-end=\"1187\"\u003eThe \u003cstrong data-start=\"851\" data-end=\"888\"\u003eLMCK-24 400\/5A Accuracy Class 0.5\u003c\/strong\u003e is a high-precision, clamp-on (split-core) current transformer built to accurately meter up to 400 A in AC electrical systems, converting it to a 5 A secondary. With Class 0.5 accuracy, it offers very low error under rated current, making it suitable for demanding metering or billing applications.\u003c\/p\u003e\n\u003chr data-start=\"1189\" data-end=\"1192\"\u003e\n\u003ch3 data-start=\"1194\" data-end=\"1210\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1212\" data-end=\"1936\"\u003e\n\u003cli data-start=\"1212\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1214\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1214\" data-end=\"1240\"\u003ePrimary Current Rating\u003c\/strong\u003e: 400 A AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1310\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1310\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1283\"\u003eSecondary Current Rating\u003c\/strong\u003e: 5 A AC — ratio of 400:5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1311\" data-end=\"1411\"\u003e\n\u003cp data-start=\"1313\" data-end=\"1411\"\u003e\u003cstrong data-start=\"1313\" data-end=\"1331\"\u003eAccuracy Class\u003c\/strong\u003e: 0.5 (±0.5% typical) — ensures high precision under rated and near-rated load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1412\" data-end=\"1529\"\u003e\n\u003cp data-start=\"1414\" data-end=\"1529\"\u003e\u003cstrong data-start=\"1414\" data-end=\"1424\"\u003eDesign\u003c\/strong\u003e: Split-core (clamp-on) — allows retrofitting, installation without disconnecting the primary conductor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1530\" data-end=\"1653\"\u003e\n\u003cp data-start=\"1532\" data-end=\"1653\"\u003e\u003cstrong data-start=\"1532\" data-end=\"1565\"\u003eRound Window \/ Inner Diameter\u003c\/strong\u003e: (typical LMCK-24 standard) ~24 mm window — suitable for many cable \/ conductor sizes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1654\" data-end=\"1786\"\u003e\n\u003cp data-start=\"1656\" data-end=\"1786\"\u003e\u003cstrong data-start=\"1656\" data-end=\"1667\"\u003eHousing\u003c\/strong\u003e: Flame-retardant plastic, moisture-protected, stable under typical ambient conditions — minimal maintenance required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1787\" data-end=\"1936\"\u003e\n\u003cp data-start=\"1789\" data-end=\"1936\"\u003e\u003cstrong data-start=\"1789\" data-end=\"1814\"\u003eSafety \/ Construction\u003c\/strong\u003e: Insulated, robust clamp mechanism; similar to others in LMCK series. Confirm isolation rating and insulation strength.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1938\" data-end=\"1941\"\u003e\n\u003ch3 data-start=\"1943\" data-end=\"1992\"\u003eTechnical Specifications (Typical \/ Expected)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1994\" data-end=\"2817\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1994\" data-end=\"2029\"\u003e\n\u003ctr data-start=\"1994\" data-end=\"2029\"\u003e\n\u003cth data-start=\"1994\" data-end=\"2010\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2010\" data-end=\"2029\" data-col-size=\"md\"\u003eValue \/ Comment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2083\" data-end=\"2817\"\u003e\n\u003ctr data-start=\"2083\" data-end=\"2106\"\u003e\n\u003ctd data-start=\"2083\" data-end=\"2091\" data-col-size=\"sm\"\u003eRatio\u003c\/td\u003e\n\u003ctd data-start=\"2091\" data-end=\"2106\" data-col-size=\"md\"\u003e400 A : 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2107\" data-end=\"2156\"\u003e\n\u003ctd data-start=\"2107\" data-end=\"2124\" data-col-size=\"sm\"\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd data-start=\"2124\" data-end=\"2156\" data-col-size=\"md\"\u003e0.5 (±0.5%) at rated current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2157\" data-end=\"2202\"\u003e\n\u003ctd data-start=\"2157\" data-end=\"2182\" data-col-size=\"sm\"\u003eWindow \/ Aperture Size\u003c\/td\u003e\n\u003ctd data-start=\"2182\" data-end=\"2202\" data-col-size=\"md\"\u003e~24 mm (LMCK-24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2203\" data-end=\"2259\"\u003e\n\u003ctd data-start=\"2203\" data-end=\"2221\" data-col-size=\"sm\"\u003eRated Frequency\u003c\/td\u003e\n\u003ctd data-start=\"2221\" data-end=\"2259\" data-col-size=\"md\"\u003e50 \/ 60 Hz (confirm with supplier)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2260\" data-end=\"2374\"\u003e\n\u003ctd data-start=\"2260\" data-end=\"2299\" data-col-size=\"sm\"\u003eFrequency Response \/ Measuring Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2299\" data-end=\"2374\"\u003ePerhaps ~10% to 120-130% or more of rated primary (common for such CTs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2375\" data-end=\"2443\"\u003e\n\u003ctd data-start=\"2375\" data-end=\"2394\" data-col-size=\"sm\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2394\" data-end=\"2443\"\u003eFlame retardant plastic (e.g. ABS or similar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2444\" data-end=\"2535\"\u003e\n\u003ctd data-start=\"2444\" data-end=\"2466\" data-col-size=\"sm\"\u003eMaximum Burden (VA)\u003c\/td\u003e\n\u003ctd data-start=\"2466\" data-end=\"2535\" data-col-size=\"md\"\u003eTo confirm — CT datasheet will give permissible load on secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2536\" data-end=\"2624\"\u003e\n\u003ctd data-start=\"2536\" data-end=\"2566\" data-col-size=\"sm\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2566\" data-end=\"2624\" data-col-size=\"md\"\u003eConfirm supplier spec (e.g. -20°C to +60°C or similar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2625\" data-end=\"2713\"\u003e\n\u003ctd data-start=\"2625\" data-end=\"2660\" data-col-size=\"sm\"\u003eInsulation \/ Dielectric Strength\u003c\/td\u003e\n\u003ctd data-start=\"2660\" data-end=\"2713\" data-col-size=\"md\"\u003eConfirm per manufacturer (e.g. isolation voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2714\" data-end=\"2817\"\u003e\n\u003ctd data-start=\"2714\" data-end=\"2729\" data-col-size=\"sm\"\u003eSafety Notes\u003c\/td\u003e\n\u003ctd data-start=\"2729\" data-end=\"2817\" data-col-size=\"md\"\u003eNever leave secondary circuit open when primary is live; ensure correct installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2819\" data-end=\"2822\"\u003e\n\u003ch3 data-start=\"2824\" data-end=\"2840\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2842\" data-end=\"3128\"\u003e\n\u003cli data-start=\"2842\" data-end=\"2914\"\u003e\n\u003cp data-start=\"2844\" data-end=\"2914\"\u003ePrecision metering in switchboards, mains distribution, panel meters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2915\" data-end=\"2980\"\u003e\n\u003cp data-start=\"2917\" data-end=\"2980\"\u003eBilling \/ energy-use measurements where low error is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2981\" data-end=\"3062\"\u003e\n\u003cp data-start=\"2983\" data-end=\"3062\"\u003eIntegration with advanced power analyzers, SCADA, building management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3063\" data-end=\"3128\"\u003e\n\u003cp data-start=\"3065\" data-end=\"3128\"\u003eRetrofitting existing installations without breaking circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3130\" data-end=\"3133\"\u003e\n\u003ch3 data-start=\"3135\" data-end=\"3171\"\u003eInstallation \u0026amp; Safety Guidelines\u003c\/h3\u003e\n\u003cul data-start=\"3173\" data-end=\"3540\"\u003e\n\u003cli data-start=\"3173\" data-end=\"3257\"\u003e\n\u003cp data-start=\"3175\" data-end=\"3257\"\u003eEnsure conductor \/ busbar passes through clamp opening without tight deformation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3258\" data-end=\"3363\"\u003e\n\u003cp data-start=\"3260\" data-end=\"3363\"\u003eAlways terminate the secondary in a suitable load (meter\/burden) — do not operate with secondary open\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3364\" data-end=\"3417\"\u003e\n\u003cp data-start=\"3366\" data-end=\"3417\"\u003eSecure clamp tightly; ensure mechanical stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3418\" data-end=\"3496\"\u003e\n\u003cp data-start=\"3420\" data-end=\"3496\"\u003eKeep CT away from strong external magnetic influences or high stray fields\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3497\" data-end=\"3540\"\u003e\n\u003cp data-start=\"3499\" data-end=\"3540\"\u003eFollow local codes and safety standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3542\" data-end=\"3545\"\u003e\n\u003ch3 data-start=\"3547\" data-end=\"3559\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"3561\" data-end=\"3815\"\u003e\n\u003cli data-start=\"3561\" data-end=\"3658\"\u003e\n\u003cp data-start=\"3563\" data-end=\"3658\"\u003eHigh accuracy (Class 0.5) reduces measurement error — good for precision monitoring \u0026amp; billing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3659\" data-end=\"3719\"\u003e\n\u003cp data-start=\"3661\" data-end=\"3719\"\u003eClamp-on design means easier installation, less downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3720\" data-end=\"3754\"\u003e\n\u003cp data-start=\"3722\" data-end=\"3754\"\u003eDurable build, low maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3755\" data-end=\"3815\"\u003e\n\u003cp data-start=\"3757\" data-end=\"3815\"\u003eCompatible with standard secondary devices expecting 5 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350714765603,"sku":null,"price":220.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/Sct-T16-Split-Core-Current-Transformer-100A-33-3mA-0-63-Inches-ID-UL-Ce.avif?v=1758398255"},{"product_id":"clamp-split-core-current-transformer-lmck-36-600-5a-accuracy-class-0-5","title":"Clamp \/ Split-Core Current Transformer LMCK-36 • 600\/5A • Accuracy Class 0.5","description":"\u003ch2 data-start=\"1093\" data-end=\"1115\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"1117\" data-end=\"1131\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"1132\" data-end=\"1593\"\u003eThe \u003cstrong data-start=\"1136\" data-end=\"1173\"\u003eLMCK-36 600\/5A Accuracy Class 0.5\u003c\/strong\u003e is a high-capacity, high-precision split-core current transformer ideal for metering, monitoring, and protection in electrical systems drawing up to 600 amps. It converts a 600 A primary current to a 5 A secondary current, with ±0.5% accuracy under rated conditions. The 36 mm aperture (window) gives flexibility for larger conductors or busbars, making it suitable for demanding industrial or commercial installations.\u003c\/p\u003e\n\u003chr data-start=\"1595\" data-end=\"1598\"\u003e\n\u003ch3 data-start=\"1600\" data-end=\"1616\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1618\" data-end=\"2354\"\u003e\n\u003cli data-start=\"1618\" data-end=\"1696\"\u003e\n\u003cp data-start=\"1620\" data-end=\"1696\"\u003e\u003cstrong data-start=\"1620\" data-end=\"1646\"\u003ePrimary Current Rating\u003c\/strong\u003e: 600 A AC \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1697\" data-end=\"1775\"\u003e\n\u003cp data-start=\"1699\" data-end=\"1775\"\u003e\u003cstrong data-start=\"1699\" data-end=\"1727\"\u003eSecondary Current Rating\u003c\/strong\u003e: 5 A AC \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1776\" data-end=\"1899\"\u003e\n\u003cp data-start=\"1778\" data-end=\"1899\"\u003e\u003cstrong data-start=\"1778\" data-end=\"1796\"\u003eAccuracy Class\u003c\/strong\u003e: 0.5 (±0.5%) — ensures quite precise measurements for metering and power monitoring under rated load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1900\" data-end=\"2030\"\u003e\n\u003cp data-start=\"1902\" data-end=\"2030\"\u003e\u003cstrong data-start=\"1902\" data-end=\"1920\"\u003eModel \/ Series\u003c\/strong\u003e: LMCK-36 — 36 mm inner diameter window \/ hole size for the conductor. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2031\" data-end=\"2171\"\u003e\n\u003cp data-start=\"2033\" data-end=\"2171\"\u003e\u003cstrong data-start=\"2033\" data-end=\"2043\"\u003eDesign\u003c\/strong\u003e: Split-core (clamp-on) with self-locking mechanism for tool-free, non-invasive mounting \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2172\" data-end=\"2354\"\u003e\n\u003cp data-start=\"2174\" data-end=\"2354\"\u003e\u003cstrong data-start=\"2174\" data-end=\"2185\"\u003eHousing\u003c\/strong\u003e: Flame-retardant plastic that meets isolation and safety norms; moisture-protected; stable performance with minimal maintenance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2356\" data-end=\"2359\"\u003e\n\u003ch3 data-start=\"2361\" data-end=\"2419\"\u003eTechnical Specifications (Typical \/ From LMCK-36 Data)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2421\" data-end=\"3184\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2421\" data-end=\"2464\"\u003e\n\u003ctr data-start=\"2421\" data-end=\"2464\"\u003e\n\u003cth data-start=\"2421\" data-end=\"2437\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2437\" data-end=\"2464\" data-col-size=\"md\"\u003eTypical Value \/ Comment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2530\" data-end=\"3184\"\u003e\n\u003ctr data-start=\"2530\" data-end=\"2625\"\u003e\n\u003ctd data-start=\"2530\" data-end=\"2559\" data-col-size=\"sm\"\u003eWindow \/ Aperture Diameter\u003c\/td\u003e\n\u003ctd data-start=\"2559\" data-end=\"2625\" data-col-size=\"md\"\u003e~36 mm (inner hole size) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2626\" data-end=\"2658\"\u003e\n\u003ctd data-start=\"2626\" data-end=\"2643\" data-col-size=\"sm\"\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd data-start=\"2643\" data-end=\"2658\" data-col-size=\"md\"\u003e0.5 (±0.5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2659\" data-end=\"2686\"\u003e\n\u003ctd data-start=\"2659\" data-end=\"2675\" data-col-size=\"sm\"\u003eCurrent Ratio\u003c\/td\u003e\n\u003ctd data-start=\"2675\" data-end=\"2686\" data-col-size=\"md\"\u003e600:5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2687\" data-end=\"2782\"\u003e\n\u003ctd data-start=\"2687\" data-end=\"2705\" data-col-size=\"sm\"\u003eRated Frequency\u003c\/td\u003e\n\u003ctd data-start=\"2705\" data-end=\"2782\" data-col-size=\"md\"\u003e50\/60 Hz (common for LMCK series) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2783\" data-end=\"2897\"\u003e\n\u003ctd data-start=\"2783\" data-end=\"2802\" data-col-size=\"sm\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd data-start=\"2802\" data-end=\"2897\" data-col-size=\"md\"\u003eFlame-retardant plastic, isolation per UL94-V0 etc. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2898\" data-end=\"3003\"\u003e\n\u003ctd data-start=\"2898\" data-end=\"2924\" data-col-size=\"sm\"\u003eBurden \/ Secondary Load\u003c\/td\u003e\n\u003ctd data-start=\"2924\" data-end=\"3003\" data-col-size=\"md\"\u003e(to be confirmed with datasheet; typical values may be in the few VA range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3004\" data-end=\"3064\"\u003e\n\u003ctd data-start=\"3004\" data-end=\"3034\" data-col-size=\"sm\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd data-start=\"3034\" data-end=\"3064\" data-col-size=\"md\"\u003e(manufacturer spec needed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3065\" data-end=\"3184\"\u003e\n\u003ctd data-start=\"3065\" data-end=\"3086\" data-col-size=\"sm\"\u003eSafety \/ Isolation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3086\" data-end=\"3184\"\u003eSecondary must never be open when primary is energized; safe insulation, protective enclosure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3186\" data-end=\"3189\"\u003e\n\u003ch3 data-start=\"3191\" data-end=\"3207\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"3209\" data-end=\"3493\"\u003e\n\u003cli data-start=\"3209\" data-end=\"3269\"\u003e\n\u003cp data-start=\"3211\" data-end=\"3269\"\u003eHigh current panel and switchboard metering \/ monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3270\" data-end=\"3334\"\u003e\n\u003cp data-start=\"3272\" data-end=\"3334\"\u003eIndustrial machinery, busbar systems, large HVAC units, etc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3335\" data-end=\"3426\"\u003e\n\u003cp data-start=\"3337\" data-end=\"3426\"\u003eRetrofit installations where existing conductors are in place and cannot be interrupted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3427\" data-end=\"3493\"\u003e\n\u003cp data-start=\"3429\" data-end=\"3493\"\u003eUse with submeters, power analyzers, energy management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3495\" data-end=\"3498\"\u003e\n\u003ch3 data-start=\"3500\" data-end=\"3536\"\u003eInstallation \u0026amp; Safety Guidelines\u003c\/h3\u003e\n\u003cul data-start=\"3538\" data-end=\"4012\"\u003e\n\u003cli data-start=\"3538\" data-end=\"3641\"\u003e\n\u003cp data-start=\"3540\" data-end=\"3641\"\u003eEnsure the conductor or busbar fits through the 36 mm window without forcing or damaging insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3642\" data-end=\"3780\"\u003e\n\u003cp data-start=\"3644\" data-end=\"3780\"\u003eAlways connect the secondary output to a load (meter, burden resistor) — do \u003cstrong data-start=\"3720\" data-end=\"3727\"\u003enot\u003c\/strong\u003e leave secondary open when the primary is energized\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3781\" data-end=\"3843\"\u003e\n\u003cp data-start=\"3783\" data-end=\"3843\"\u003eClamp fully closed and locked; ensure mechanical stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3844\" data-end=\"3938\"\u003e\n\u003cp data-start=\"3846\" data-end=\"3938\"\u003eAvoid placing near strong external magnetic interference or extreme environmental exposure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3939\" data-end=\"4012\"\u003e\n\u003cp data-start=\"3941\" data-end=\"4012\"\u003eFollow relevant local safety, grounding, electrical code requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4014\" data-end=\"4017\"\u003e\n\u003ch3 data-start=\"4019\" data-end=\"4031\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"4033\" data-end=\"4393\"\u003e\n\u003cli data-start=\"4033\" data-end=\"4175\"\u003e\n\u003cp data-start=\"4035\" data-end=\"4175\"\u003eVery good measurement accuracy (0.5%) — suitable for applications where precision matters (billing, energy auditing, sensitive monitoring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4176\" data-end=\"4255\"\u003e\n\u003cp data-start=\"4178\" data-end=\"4255\"\u003eNon-intrusive installation — clamp-on design reduces downtime \/ labor costs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4256\" data-end=\"4332\"\u003e\n\u003cp data-start=\"4258\" data-end=\"4332\"\u003eCapable of handling 600 A on primary, which works for fairly large loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4333\" data-end=\"4393\"\u003e\n\u003cp data-start=\"4335\" data-end=\"4393\"\u003eDurable housing, moisture protection, stable performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350716436771,"sku":null,"price":290.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/rayleigh_instruments_ri-cts036_alternergy_1_1.jpg?v=1758398256"},{"product_id":"clamp-split-core-current-transformer-lmck-50-800-5a-accuracy-class-0-5","title":"Clamp \/ Split-Core Current Transformer LMCK-50 • 800\/5A • Accuracy Class 0.5","description":"\u003ch2 data-start=\"836\" data-end=\"858\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"860\" data-end=\"874\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"875\" data-end=\"1289\"\u003eThe \u003cstrong data-start=\"879\" data-end=\"916\"\u003eLMCK-50 800\/5A Accuracy Class 0.5\u003c\/strong\u003e is a split-core (clamp-on) current transformer designed for accurate measurement of high AC currents without interrupting the primary circuit. With a primary rating of \u003cstrong data-start=\"1085\" data-end=\"1094\"\u003e800 A\u003c\/strong\u003e and secondary output of \u003cstrong data-start=\"1119\" data-end=\"1126\"\u003e5 A\u003c\/strong\u003e, and an error tolerance of ±0.5% under rated conditions, it suits precision metering and monitoring in demanding industrial, commercial or high-load applications.\u003c\/p\u003e\n\u003chr data-start=\"1291\" data-end=\"1294\"\u003e\n\u003ch3 data-start=\"1296\" data-end=\"1312\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1314\" data-end=\"2202\"\u003e\n\u003cli data-start=\"1314\" data-end=\"1445\"\u003e\n\u003cp data-start=\"1316\" data-end=\"1445\"\u003e\u003cstrong data-start=\"1316\" data-end=\"1334\"\u003eModel \/ Series\u003c\/strong\u003e: LMCK-50 (Zhikai) – part of the split-core current transformer family. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1446\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1448\" data-end=\"1516\"\u003e\u003cstrong data-start=\"1448\" data-end=\"1466\"\u003ePrimary Rating\u003c\/strong\u003e: 800 A AC \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1517\" data-end=\"1587\"\u003e\n\u003cp data-start=\"1519\" data-end=\"1587\"\u003e\u003cstrong data-start=\"1519\" data-end=\"1539\"\u003eSecondary Rating\u003c\/strong\u003e: 5 A AC \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1588\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1590\" data-end=\"1703\"\u003e\u003cstrong data-start=\"1590\" data-end=\"1608\"\u003eAccuracy Class\u003c\/strong\u003e: 0.5 (i.e., ±0.5%) — good for precision metering applications where lower error is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1704\" data-end=\"1861\"\u003e\n\u003cp data-start=\"1706\" data-end=\"1861\"\u003e\u003cstrong data-start=\"1706\" data-end=\"1734\"\u003eWindow \/ Inner Hole Size\u003c\/strong\u003e: ~50 mm (inner diameter), matching LMCK-50 family which supports up to 50mm hole size. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1862\" data-end=\"2012\"\u003e\n\u003cp data-start=\"1864\" data-end=\"2012\"\u003e\u003cstrong data-start=\"1864\" data-end=\"1875\"\u003eHousing\u003c\/strong\u003e: Flame-retardant plastic enclosure, moisture-protected, stable performance, minimal maintenance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2202\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2202\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2044\"\u003eClamp \/ Split-Core Design\u003c\/strong\u003e: Self locking clamp mechanism, allowing for easy installation \/ retrofit without disconnecting the primary conductor. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2204\" data-end=\"2207\"\u003e\n\u003ch3 data-start=\"2209\" data-end=\"2261\"\u003eTechnical Specifications (As Expected \/ Typical)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2263\" data-end=\"3274\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2263\" data-end=\"2306\"\u003e\n\u003ctr data-start=\"2263\" data-end=\"2306\"\u003e\n\u003cth data-start=\"2263\" data-end=\"2279\" data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2279\" data-end=\"2306\" data-col-size=\"lg\"\u003eDetail \/ Expected Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2371\" data-end=\"3274\"\u003e\n\u003ctr data-start=\"2371\" data-end=\"2415\"\u003e\n\u003ctd data-start=\"2371\" data-end=\"2403\" data-col-size=\"md\"\u003ePrimary current rating (In)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2403\" data-end=\"2415\"\u003e800 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2416\" data-end=\"2458\"\u003e\n\u003ctd data-start=\"2416\" data-end=\"2448\" data-col-size=\"md\"\u003eSecondary current rating (Is)\u003c\/td\u003e\n\u003ctd data-start=\"2448\" data-end=\"2458\" data-col-size=\"lg\"\u003e5 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2459\" data-end=\"2502\"\u003e\n\u003ctd data-start=\"2459\" data-end=\"2491\" data-col-size=\"md\"\u003eTransformation ratio\u003c\/td\u003e\n\u003ctd data-start=\"2491\" data-end=\"2502\" data-col-size=\"lg\"\u003e800 : 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2503\" data-end=\"2567\"\u003e\n\u003ctd data-start=\"2503\" data-end=\"2535\" data-col-size=\"md\"\u003eAccuracy class\u003c\/td\u003e\n\u003ctd data-start=\"2535\" data-end=\"2567\" data-col-size=\"lg\"\u003e0.5 (±0.5%) at rated current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2568\" data-end=\"2648\"\u003e\n\u003ctd data-start=\"2568\" data-end=\"2600\" data-col-size=\"md\"\u003eInner diameter \/ window size\u003c\/td\u003e\n\u003ctd data-start=\"2600\" data-end=\"2648\" data-col-size=\"lg\"\u003e~50 mm \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2649\" data-end=\"2716\"\u003e\n\u003ctd data-start=\"2649\" data-end=\"2680\" data-col-size=\"md\"\u003eRated frequency\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2680\" data-end=\"2716\"\u003e50\/60 Hz (confirm supplier spec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2717\" data-end=\"2840\"\u003e\n\u003ctd data-start=\"2717\" data-end=\"2748\" data-col-size=\"md\"\u003eHousing material\u003c\/td\u003e\n\u003ctd data-start=\"2748\" data-end=\"2840\" data-col-size=\"lg\"\u003eFlame retardant plastic; inert, moisture-protected \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2841\" data-end=\"2946\"\u003e\n\u003ctd data-start=\"2841\" data-end=\"2881\" data-col-size=\"md\"\u003eBurden (maximum VA load of secondary)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2881\" data-end=\"2946\"\u003eTo be confirmed with datasheet — typical CT load specs needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2947\" data-end=\"3074\"\u003e\n\u003ctd data-start=\"2947\" data-end=\"2994\" data-col-size=\"md\"\u003eOperating temperature \/ environmental limits\u003c\/td\u003e\n\u003ctd data-start=\"2994\" data-end=\"3074\" data-col-size=\"lg\"\u003eSupplier-specified; likely standard industrial ambient (e.g. -20°C to +60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3075\" data-end=\"3274\"\u003e\n\u003ctd data-start=\"3075\" data-end=\"3106\" data-col-size=\"md\"\u003eSafety \/ Insulation\u003c\/td\u003e\n\u003ctd data-start=\"3106\" data-end=\"3274\" data-col-size=\"lg\"\u003ePlastic enclosure; secondary winding \u003cem data-start=\"3145\" data-end=\"3163\"\u003emust not be open\u003c\/em\u003e when primary is energized; isolation meets UL94-V0 for plastic case. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3276\" data-end=\"3279\"\u003e\n\u003ch3 data-start=\"3281\" data-end=\"3297\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"3299\" data-end=\"3609\"\u003e\n\u003cli data-start=\"3299\" data-end=\"3381\"\u003e\n\u003cp data-start=\"3301\" data-end=\"3381\"\u003eHigh current load monitoring in industrial switchboards or distribution panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3382\" data-end=\"3452\"\u003e\n\u003cp data-start=\"3384\" data-end=\"3452\"\u003ePrecision energy metering, auditing and power quality applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3453\" data-end=\"3533\"\u003e\n\u003cp data-start=\"3455\" data-end=\"3533\"\u003eIntegration with power analyzers, PLCs, SCADA or building management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3609\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3609\"\u003eUse where the primary cable\/conductor cannot be disconnected (retrofit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3611\" data-end=\"3614\"\u003e\n\u003ch3 data-start=\"3616\" data-end=\"3647\"\u003eInstallation \u0026amp; Safety Notes\u003c\/h3\u003e\n\u003cul data-start=\"3649\" data-end=\"4250\"\u003e\n\u003cli data-start=\"3649\" data-end=\"3783\"\u003e\n\u003cp data-start=\"3651\" data-end=\"3783\"\u003eEnsure the conductor or busbar fits through the ~50 mm opening without strain, deformation, or damage to the conductor insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3784\" data-end=\"3969\"\u003e\n\u003cp data-start=\"3786\" data-end=\"3969\"\u003eThe secondary circuit must always be terminated (connected to the measuring device or burden resistor); never leave the secondary circuit open while the primary is carrying current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3970\" data-end=\"4073\"\u003e\n\u003cp data-start=\"3972\" data-end=\"4073\"\u003eSecure the clamp fully, ensure mechanical integrity, avoid mechanical vibration affecting readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4074\" data-end=\"4175\"\u003e\n\u003cp data-start=\"4076\" data-end=\"4175\"\u003eAvoid placing the CT in proximity of strong external magnetic fields that could distort readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4176\" data-end=\"4250\"\u003e\n\u003cp data-start=\"4178\" data-end=\"4250\"\u003eFollow local electrical codes for grounding, insulation, enclosure, etc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4252\" data-end=\"4255\"\u003e\n\u003ch3 data-start=\"4257\" data-end=\"4269\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"4271\" data-end=\"4609\"\u003e\n\u003cli data-start=\"4271\" data-end=\"4371\"\u003e\n\u003cp data-start=\"4273\" data-end=\"4371\"\u003e±0.5% accuracy gives high fidelity in measurements—good for billing, precision energy monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4372\" data-end=\"4438\"\u003e\n\u003cp data-start=\"4374\" data-end=\"4438\"\u003eLarge aperture (~50 mm) allows for large conductors or busbars\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4439\" data-end=\"4529\"\u003e\n\u003cp data-start=\"4441\" data-end=\"4529\"\u003eClamp-on installation means easier, safer retrofitting without interrupting operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4530\" data-end=\"4609\"\u003e\n\u003cp data-start=\"4532\" data-end=\"4609\"\u003eDurable construction (plastic, moisture protection) means lower maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350726037795,"sku":null,"price":550.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/CTA5X100A5A_SPL.webp?v=1758398255"},{"product_id":"clamp-split-core-current-transformer-lmck-50-1000-5a-accuracy-class-0-5","title":"Clamp \/ Split-Core Current Transformer LMCK-50 • 1000\/5A • Accuracy Class 0.5","description":"\u003ch2 data-start=\"770\" data-end=\"792\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"794\" data-end=\"808\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"809\" data-end=\"1295\"\u003eThe \u003cstrong data-start=\"813\" data-end=\"851\"\u003eLMCK-50 1000\/5A Accuracy Class 0.5\u003c\/strong\u003e is a high-capacity, high-accuracy split-core (clamp-on) current transformer designed for demanding electrical measurement applications. With a primary current rating of \u003cstrong data-start=\"1021\" data-end=\"1034\"\u003e1000 A AC\u003c\/strong\u003e and a secondary output of \u003cstrong data-start=\"1061\" data-end=\"1068\"\u003e5 A\u003c\/strong\u003e, this CT delivers precise measurements (±0.5%) under rated conditions. Featuring a ~50 mm aperture, it accommodates large conductors or busbars, making it suitable for industrial, large commercial and energy metering settings.\u003c\/p\u003e\n\u003chr data-start=\"1297\" data-end=\"1300\"\u003e\n\u003ch3 data-start=\"1302\" data-end=\"1318\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1320\" data-end=\"2040\"\u003e\n\u003cli data-start=\"1320\" data-end=\"1392\"\u003e\n\u003cp data-start=\"1322\" data-end=\"1392\"\u003e\u003cstrong data-start=\"1322\" data-end=\"1341\"\u003ePrimary Current\u003c\/strong\u003e: 1000 A AC \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1393\" data-end=\"1464\"\u003e\n\u003cp data-start=\"1395\" data-end=\"1464\"\u003e\u003cstrong data-start=\"1395\" data-end=\"1416\"\u003eSecondary Current\u003c\/strong\u003e: 5 A AC \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1465\" data-end=\"1578\"\u003e\n\u003cp data-start=\"1467\" data-end=\"1578\"\u003e\u003cstrong data-start=\"1467\" data-end=\"1485\"\u003eAccuracy Class\u003c\/strong\u003e: 0.5 (±0.5%) — high precision under rated conditions \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1579\" data-end=\"1728\"\u003e\n\u003cp data-start=\"1581\" data-end=\"1728\"\u003e\u003cstrong data-start=\"1581\" data-end=\"1599\"\u003eModel \/ Series\u003c\/strong\u003e: LMCK-50 — part of Zhikai’s split core (clamp-on) LMCK line with large aperture (≈50 mm) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1729\" data-end=\"1925\"\u003e\n\u003cp data-start=\"1731\" data-end=\"1925\"\u003e\u003cstrong data-start=\"1731\" data-end=\"1750\"\u003eHousing \u0026amp; Build\u003c\/strong\u003e: Flame-retardant plastic, moisture protected; stable under normal operating conditions. Designed for durability and safe installation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1926\" data-end=\"2040\"\u003e\n\u003cp data-start=\"1928\" data-end=\"2040\"\u003e\u003cstrong data-start=\"1928\" data-end=\"1957\"\u003eClamp \/ Split-Core Design\u003c\/strong\u003e: Self-locking clamp type; allows installation without disconnecting the conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2042\" data-end=\"2045\"\u003e\n\u003ch3 data-start=\"2047\" data-end=\"2096\"\u003eTechnical Specifications (Typical \/ Expected)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2098\" data-end=\"3021\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2098\" data-end=\"2122\"\u003e\n\u003ctr data-start=\"2098\" data-end=\"2122\"\u003e\n\u003cth data-start=\"2098\" data-end=\"2105\" data-col-size=\"sm\"\u003eSpec\u003c\/th\u003e\n\u003cth data-start=\"2105\" data-end=\"2122\" data-col-size=\"lg\"\u003eValue \/ Notes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2146\" data-end=\"3021\"\u003e\n\u003ctr data-start=\"2146\" data-end=\"2192\"\u003e\n\u003ctd data-start=\"2146\" data-end=\"2176\" data-col-size=\"sm\"\u003eRatio (Primary : Secondary)\u003c\/td\u003e\n\u003ctd data-start=\"2176\" data-end=\"2192\" data-col-size=\"lg\"\u003e\u003cstrong data-start=\"2178\" data-end=\"2190\"\u003e1000:5 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2193\" data-end=\"2297\"\u003e\n\u003ctd data-start=\"2193\" data-end=\"2222\" data-col-size=\"sm\"\u003eAperture \/ Window Diameter\u003c\/td\u003e\n\u003ctd data-start=\"2222\" data-end=\"2297\" data-col-size=\"lg\"\u003eApprox. \u003cstrong data-start=\"2232\" data-end=\"2241\"\u003e50 mm\u003c\/strong\u003e (LMCK-50 model) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2298\" data-end=\"2393\"\u003e\n\u003ctd data-start=\"2298\" data-end=\"2315\" data-col-size=\"sm\"\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd data-start=\"2315\" data-end=\"2393\" data-col-size=\"lg\"\u003e0.5 (±0.5%) at or near rated current \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2394\" data-end=\"2497\"\u003e\n\u003ctd data-start=\"2394\" data-end=\"2406\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-start=\"2406\" data-end=\"2497\" data-col-size=\"lg\"\u003eTypically 50 \/ 60 Hz (standard for LMCK series) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2498\" data-end=\"2626\"\u003e\n\u003ctd data-start=\"2498\" data-end=\"2517\" data-col-size=\"sm\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd data-start=\"2517\" data-end=\"2626\" data-col-size=\"lg\"\u003eFlame-retardant plastic; adequate insulation, moisture protection \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2627\" data-end=\"2755\"\u003e\n\u003ctd data-start=\"2627\" data-end=\"2651\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2651\" data-end=\"2755\" data-col-size=\"lg\"\u003e(To be confirmed with supplier) — typical ranges for similar CTs are approx. -25°C to +60°C or more.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2756\" data-end=\"2882\"\u003e\n\u003ctd data-start=\"2756\" data-end=\"2781\" data-col-size=\"sm\"\u003eBurden \/ Rated VA Load\u003c\/td\u003e\n\u003ctd data-start=\"2781\" data-end=\"2882\" data-col-size=\"lg\"\u003e(Supplier datasheet required) — likely to be several VA (depending on secondary load and cabling)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2883\" data-end=\"3021\"\u003e\n\u003ctd data-start=\"2883\" data-end=\"2904\" data-col-size=\"sm\"\u003eStandards \/ Safety\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2904\" data-end=\"3021\"\u003eDesigned to meet safety and measurement standards; ensure proper insulation, avoid open secondary under load etc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3023\" data-end=\"3026\"\u003e\n\u003ch3 data-start=\"3028\" data-end=\"3044\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"3046\" data-end=\"3382\"\u003e\n\u003cli data-start=\"3046\" data-end=\"3139\"\u003e\n\u003cp data-start=\"3048\" data-end=\"3139\"\u003eEnergy metering \u0026amp; billing systems, especially in industrial plants or large installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3140\" data-end=\"3226\"\u003e\n\u003cp data-start=\"3142\" data-end=\"3226\"\u003eMonitoring of heavy loads: large motors, transformer feeds, busbars, service mains\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3227\" data-end=\"3302\"\u003e\n\u003cp data-start=\"3229\" data-end=\"3302\"\u003eRetrofitting into existing wiring without interruption (clamp-on style)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3303\" data-end=\"3382\"\u003e\n\u003cp data-start=\"3305\" data-end=\"3382\"\u003eUse with power analyzers, monitoring equipment, building management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3384\" data-end=\"3387\"\u003e\n\u003ch3 data-start=\"3389\" data-end=\"3420\"\u003eInstallation \u0026amp; Safety Notes\u003c\/h3\u003e\n\u003cul data-start=\"3422\" data-end=\"3924\"\u003e\n\u003cli data-start=\"3422\" data-end=\"3532\"\u003e\n\u003cp data-start=\"3424\" data-end=\"3532\"\u003eMake sure the conductor or busbar fits through the ~50 mm aperture without strain or bending of insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3533\" data-end=\"3663\"\u003e\n\u003cp data-start=\"3535\" data-end=\"3663\"\u003eAlways connect the secondary side to a measurement device or load (i.e. never leave secondary open while primary is energized)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3664\" data-end=\"3744\"\u003e\n\u003cp data-start=\"3666\" data-end=\"3744\"\u003eMount clamp securely and ensure full closure \/ locking for accuracy \u0026amp; safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3745\" data-end=\"3864\"\u003e\n\u003cp data-start=\"3747\" data-end=\"3864\"\u003eAvoid installing in environments with excessive moisture, strong magnetic interference, or temperatures beyond spec\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3865\" data-end=\"3924\"\u003e\n\u003cp data-start=\"3867\" data-end=\"3924\"\u003eFollow applicable electrical codes and safety standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3926\" data-end=\"3929\"\u003e\n\u003ch3 data-start=\"3931\" data-end=\"3943\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"3945\" data-end=\"4297\"\u003e\n\u003cli data-start=\"3945\" data-end=\"4049\"\u003e\n\u003cp data-start=\"3947\" data-end=\"4049\"\u003eHigh precision (Class 0.5) reduces measurement error — supports accurate energy tracking and billing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4050\" data-end=\"4138\"\u003e\n\u003cp data-start=\"4052\" data-end=\"4138\"\u003eLarge aperture makes it practical for high current conductors or heavy installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4139\" data-end=\"4230\"\u003e\n\u003cp data-start=\"4141\" data-end=\"4230\"\u003eClamp-on design allows for easier installation and retrofitting without system shutdown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4231\" data-end=\"4297\"\u003e\n\u003cp data-start=\"4233\" data-end=\"4297\"\u003eDurable build with protective housing reduces maintenance cost\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350735606051,"sku":null,"price":600.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/xprecision-digital-pda6405-400-split-core-ac-current-transformer.jpg.pagespeed.ic.1lkwIB3y8z.webp?v=1758398255"},{"product_id":"clamp-split-core-current-transformer-lmck-50-1200-5a-accuracy-class-0-5","title":"Clamp \/ Split-Core Current Transformer LMCK-50 • 1200\/5A • Accuracy Class 0.5","description":"\u003ch2 data-start=\"995\" data-end=\"1017\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"1019\" data-end=\"1033\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"1034\" data-end=\"1532\"\u003eThe \u003cstrong data-start=\"1038\" data-end=\"1076\"\u003eLMCK-50 1200\/5A Accuracy Class 0.5\u003c\/strong\u003e is a high-capacity, high-precision clamp-on (split-core) current transformer designed for AC systems where precise metering is required. With a primary current rating of \u003cstrong data-start=\"1247\" data-end=\"1257\"\u003e1200 A\u003c\/strong\u003e and a standard secondary output of \u003cstrong data-start=\"1293\" data-end=\"1300\"\u003e5 A\u003c\/strong\u003e, and with an error tolerance of ±0.5% under rated conditions, this CT is suitable for demanding industrial, commercial, or power monitoring applications. Its 50 mm inner aperture allows accommodation of large conductors or busbars.\u003c\/p\u003e\n\u003chr data-start=\"1534\" data-end=\"1537\"\u003e\n\u003ch3 data-start=\"1539\" data-end=\"1555\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1557\" data-end=\"2290\"\u003e\n\u003cli data-start=\"1557\" data-end=\"1653\"\u003e\n\u003cp data-start=\"1559\" data-end=\"1653\"\u003e\u003cstrong data-start=\"1559\" data-end=\"1577\"\u003eModel \/ Series\u003c\/strong\u003e: LMCK-50 – from Zhikai’s LMCK line. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1654\" data-end=\"1733\"\u003e\n\u003cp data-start=\"1656\" data-end=\"1733\"\u003e\u003cstrong data-start=\"1656\" data-end=\"1682\"\u003ePrimary Current Rating\u003c\/strong\u003e: 1200 A AC \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1734\" data-end=\"1812\"\u003e\n\u003cp data-start=\"1736\" data-end=\"1812\"\u003e\u003cstrong data-start=\"1736\" data-end=\"1764\"\u003eSecondary Current Rating\u003c\/strong\u003e: 5 A AC \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1813\" data-end=\"1909\"\u003e\n\u003cp data-start=\"1815\" data-end=\"1909\"\u003e\u003cstrong data-start=\"1815\" data-end=\"1833\"\u003eAccuracy Class\u003c\/strong\u003e: 0.5 (±0.5%) – suitable for precise metering or billing-level monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1910\" data-end=\"2029\"\u003e\n\u003cp data-start=\"1912\" data-end=\"2029\"\u003e\u003cstrong data-start=\"1912\" data-end=\"1949\"\u003eAperture\/Window (Inner Hole) Size\u003c\/strong\u003e: ~ 50 mm – for large cables or busbars. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2030\" data-end=\"2134\"\u003e\n\u003cp data-start=\"2032\" data-end=\"2134\"\u003e\u003cstrong data-start=\"2032\" data-end=\"2040\"\u003eType\u003c\/strong\u003e: Split-core clamp-on design, allowing installation without disconnecting primary conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2135\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2137\" data-end=\"2290\"\u003e\u003cstrong data-start=\"2137\" data-end=\"2159\"\u003eHousing \/ Material\u003c\/strong\u003e: Flame-retardant plastic, moisture resistant, durable and stable with minimal maintenance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2292\" data-end=\"2295\"\u003e\n\u003ch3 data-start=\"2297\" data-end=\"2325\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2327\" data-end=\"2886\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2327\" data-end=\"2362\"\u003e\n\u003ctr data-start=\"2327\" data-end=\"2362\"\u003e\n\u003cth data-start=\"2327\" data-end=\"2343\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2343\" data-end=\"2362\" data-col-size=\"md\"\u003eValue \/ Typical\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2413\" data-end=\"2886\"\u003e\n\u003ctr data-start=\"2413\" data-end=\"2455\"\u003e\n\u003ctd data-start=\"2413\" data-end=\"2441\" data-col-size=\"sm\"\u003ePrimary : Secondary Ratio\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2441\" data-end=\"2455\"\u003e1200 : 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2456\" data-end=\"2505\"\u003e\n\u003ctd data-start=\"2456\" data-end=\"2473\" data-col-size=\"sm\"\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd data-start=\"2473\" data-end=\"2505\" data-col-size=\"md\"\u003e0.5 (±0.5%) under rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2506\" data-end=\"2580\"\u003e\n\u003ctd data-start=\"2506\" data-end=\"2532\" data-col-size=\"sm\"\u003eInner diameter \/ window\u003c\/td\u003e\n\u003ctd data-start=\"2532\" data-end=\"2580\" data-col-size=\"md\"\u003e~50 mm \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2581\" data-end=\"2641\"\u003e\n\u003ctd data-start=\"2581\" data-end=\"2599\" data-col-size=\"sm\"\u003eRated Frequency\u003c\/td\u003e\n\u003ctd data-start=\"2599\" data-end=\"2641\" data-col-size=\"md\"\u003e~ 50 \/ 60 Hz (typical for LMCK series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2642\" data-end=\"2718\"\u003e\n\u003ctd data-start=\"2642\" data-end=\"2661\" data-col-size=\"sm\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd data-start=\"2661\" data-end=\"2718\" data-col-size=\"md\"\u003eFlame-retardant plastic; enclosed, moisture protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2719\" data-end=\"2787\"\u003e\n\u003ctd data-start=\"2719\" data-end=\"2743\" data-col-size=\"sm\"\u003eMechanical \/ Mounting\u003c\/td\u003e\n\u003ctd data-start=\"2743\" data-end=\"2787\" data-col-size=\"md\"\u003eSplit-core, self-locking clamp mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2788\" data-end=\"2886\"\u003e\n\u003ctd data-start=\"2788\" data-end=\"2812\" data-col-size=\"sm\"\u003eImportant Safety Note\u003c\/td\u003e\n\u003ctd data-start=\"2812\" data-end=\"2886\" data-col-size=\"md\"\u003eSecondary winding must not be open-circuited when primary is energized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2888\" data-end=\"2891\"\u003e\n\u003ch3 data-start=\"2893\" data-end=\"2909\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2911\" data-end=\"3270\"\u003e\n\u003cli data-start=\"2911\" data-end=\"3000\"\u003e\n\u003cp data-start=\"2913\" data-end=\"3000\"\u003eHigh-current load monitoring in switchgear, industrial panels and distribution boards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3001\" data-end=\"3090\"\u003e\n\u003cp data-start=\"3003\" data-end=\"3090\"\u003ePrecise energy metering, power quality measurement, billing or audit grade monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3091\" data-end=\"3190\"\u003e\n\u003cp data-start=\"3093\" data-end=\"3190\"\u003eRetrofitting in existing installations without shutting off service or disconnecting conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3191\" data-end=\"3270\"\u003e\n\u003cp data-start=\"3193\" data-end=\"3270\"\u003eIntegration with power analyzers, industrial controllers, SCADA\/BMS systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3272\" data-end=\"3275\"\u003e\n\u003ch3 data-start=\"3277\" data-end=\"3313\"\u003eInstallation \u0026amp; Safety Guidelines\u003c\/h3\u003e\n\u003cul data-start=\"3315\" data-end=\"3911\"\u003e\n\u003cli data-start=\"3315\" data-end=\"3426\"\u003e\n\u003cp data-start=\"3317\" data-end=\"3426\"\u003eEnsure the conductor (cable or busbar) fits cleanly through the ~50 mm aperture without damaging insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3427\" data-end=\"3632\"\u003e\n\u003cp data-start=\"3429\" data-end=\"3632\"\u003eAlways connect the secondary side to a burden (meter or resistor); do \u003cstrong data-start=\"3499\" data-end=\"3506\"\u003enot\u003c\/strong\u003e leave the secondary open when the primary is energized – this is critical for safety and to avoid excessive voltage buildup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3633\" data-end=\"3718\"\u003e\n\u003cp data-start=\"3635\" data-end=\"3718\"\u003eSecure the clamp fully; mechanical stability is important for consistent readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3719\" data-end=\"3826\"\u003e\n\u003cp data-start=\"3721\" data-end=\"3826\"\u003eAvoid exposing the CT to temperatures, moisture or electromagnetic interference beyond its rated limits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3827\" data-end=\"3911\"\u003e\n\u003cp data-start=\"3829\" data-end=\"3911\"\u003eFollow all applicable electrical codes and safety standards in your jurisdiction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3913\" data-end=\"3916\"\u003e\n\u003ch3 data-start=\"3918\" data-end=\"3930\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"3932\" data-end=\"4274\"\u003e\n\u003cli data-start=\"3932\" data-end=\"4027\"\u003e\n\u003cp data-start=\"3934\" data-end=\"4027\"\u003eHigh precision (0.5% accuracy) gives confidence in metering \/ billing and measurement tasks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4028\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4030\" data-end=\"4115\"\u003eThe large aperture and high primary current capacity handle demanding installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4116\" data-end=\"4207\"\u003e\n\u003cp data-start=\"4118\" data-end=\"4207\"\u003eClamp-on design eases installation and maintenance; no need to break primary conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4208\" data-end=\"4274\"\u003e\n\u003cp data-start=\"4210\" data-end=\"4274\"\u003eDurable, low-maintenance construction – cost savings over time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350742225187,"sku":null,"price":630.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/current-instrument-transformers-500x500.webp?v=1758398255"},{"product_id":"lmhk-58-50-80-mm-window-clamp-split-core-current-transformer-1600-5a-accuracy-class-0-5","title":"LMHK-58 (50×80 mm Window) Clamp \/ Split-Core Current Transformer • 1600\/5A • Accuracy Class 0.5","description":"\u003ch2 data-start=\"507\" data-end=\"529\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"531\" data-end=\"545\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"546\" data-end=\"934\"\u003eThe \u003cstrong data-start=\"550\" data-end=\"599\"\u003eLMHK-58 (50×80 mm) 1600\/5A Accuracy Class 0.5\u003c\/strong\u003e current transformer is a precision, open\/clamp-on (split‐core) transformer designed for monitoring high currents in power systems. With a large aperture of approx. 50×80 mm, and a ratio of 1600 A primary to 5 A secondary, it delivers accurate measurement (±0.5%) suitable for demanding metering, protection, or power monitoring tasks.\u003c\/p\u003e\n\u003chr data-start=\"936\" data-end=\"939\"\u003e\n\u003ch3 data-start=\"941\" data-end=\"957\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"959\" data-end=\"1766\"\u003e\n\u003cli data-start=\"959\" data-end=\"1037\"\u003e\n\u003cp data-start=\"961\" data-end=\"1037\"\u003e\u003cstrong data-start=\"961\" data-end=\"979\"\u003eModel \/ Series\u003c\/strong\u003e: HK-58 (LMHK-58) split-core type with clamp\/open design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1038\" data-end=\"1117\"\u003e\n\u003cp data-start=\"1040\" data-end=\"1117\"\u003e\u003cstrong data-start=\"1040\" data-end=\"1066\"\u003ePrimary Current Rating\u003c\/strong\u003e: 1600 A AC \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1118\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1120\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1120\" data-end=\"1148\"\u003eSecondary Current Rating\u003c\/strong\u003e: 5 A AC \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1317\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1317\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1217\"\u003eAccuracy Class\u003c\/strong\u003e: 0.5 (±0.5%) under rated load, for precision metering tasks \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1318\" data-end=\"1447\"\u003e\n\u003cp data-start=\"1320\" data-end=\"1447\"\u003e\u003cstrong data-start=\"1320\" data-end=\"1346\"\u003eWindow \/ Aperture Size\u003c\/strong\u003e: Approx. 50×80 mm to accommodate large conductors or busbars \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1448\" data-end=\"1594\"\u003e\n\u003cp data-start=\"1450\" data-end=\"1594\"\u003e\u003cstrong data-start=\"1450\" data-end=\"1458\"\u003eType\u003c\/strong\u003e: Split-core, clamp\/open style – allows installation without disconnecting the primary conductor \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1595\" data-end=\"1766\"\u003e\n\u003cp data-start=\"1597\" data-end=\"1766\"\u003e\u003cstrong data-start=\"1597\" data-end=\"1617\"\u003eHousing Material\u003c\/strong\u003e: Flame retardant plastic case, moisture resistant; built for stable performance in harsh industrial settings \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1768\" data-end=\"1771\"\u003e\n\u003ch3 data-start=\"1773\" data-end=\"1822\"\u003eTechnical Specifications (Typical \/ Expected)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1824\" data-end=\"2797\" class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 100.036%; height: 294px;\"\u003e\n\u003cthead data-start=\"1824\" data-end=\"1867\"\u003e\n\u003ctr data-start=\"1824\" data-end=\"1867\" style=\"height: 19.6px;\"\u003e\n\u003cth data-start=\"1824\" data-end=\"1840\" data-col-size=\"sm\" style=\"width: 23.9706%; height: 19.6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1840\" data-end=\"1867\" data-col-size=\"lg\" style=\"width: 73.5695%; height: 19.6px;\"\u003eDetail \/ Expected Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1935\" data-end=\"2797\"\u003e\n\u003ctr data-start=\"1935\" data-end=\"1979\" style=\"height: 39.2px;\"\u003e\n\u003ctd data-start=\"1935\" data-end=\"1965\" data-col-size=\"sm\" style=\"width: 23.9706%; height: 39.2px;\"\u003eRatio (Primary : Secondary)\u003c\/td\u003e\n\u003ctd data-start=\"1965\" data-end=\"1979\" data-col-size=\"lg\" style=\"width: 73.5695%; height: 39.2px;\"\u003e1600 : 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1980\" data-end=\"2050\" style=\"height: 19.6px;\"\u003e\n\u003ctd data-start=\"1980\" data-end=\"1997\" data-col-size=\"sm\" style=\"width: 23.9706%; height: 19.6px;\"\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd data-start=\"1997\" data-end=\"2050\" data-col-size=\"lg\" style=\"width: 73.5695%; height: 19.6px;\"\u003e0.5 (±0.5%) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2051\" data-end=\"2151\" style=\"height: 39.2px;\"\u003e\n\u003ctd data-start=\"2051\" data-end=\"2076\" data-col-size=\"sm\" style=\"width: 23.9706%; height: 39.2px;\"\u003eAperture \/ Window Size\u003c\/td\u003e\n\u003ctd data-start=\"2076\" data-end=\"2151\" data-col-size=\"lg\" style=\"width: 73.5695%; height: 39.2px;\"\u003e~ 50×80 mm (busbar \/ cable space) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2152\" data-end=\"2230\" style=\"height: 19.6px;\"\u003e\n\u003ctd data-start=\"2152\" data-end=\"2170\" data-col-size=\"sm\" style=\"width: 23.9706%; height: 19.6px;\"\u003eRated Frequency\u003c\/td\u003e\n\u003ctd data-start=\"2170\" data-end=\"2230\" data-col-size=\"lg\" style=\"width: 73.5695%; height: 19.6px;\"\u003e50-60 Hz (usually) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2231\" data-end=\"2379\" style=\"height: 39.2px;\"\u003e\n\u003ctd data-start=\"2231\" data-end=\"2257\" data-col-size=\"sm\" style=\"width: 23.9706%; height: 39.2px;\"\u003eBurden \/ Secondary Load\u003c\/td\u003e\n\u003ctd data-start=\"2257\" data-end=\"2379\" data-col-size=\"lg\" style=\"width: 73.5695%; height: 39.2px;\"\u003eTypical VA rating for HK-58 at 1600\/5A, class 0.5 often ~10 VA — check datasheet \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2380\" data-end=\"2491\" style=\"height: 39.2px;\"\u003e\n\u003ctd data-start=\"2380\" data-end=\"2404\" data-col-size=\"sm\" style=\"width: 23.9706%; height: 39.2px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2404\" data-end=\"2491\" data-col-size=\"lg\" style=\"width: 73.5695%; height: 39.2px;\"\u003eApprox. -25 °C to +75 °C, industrial rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2492\" data-end=\"2641\" style=\"height: 39.2px;\"\u003e\n\u003ctd data-start=\"2492\" data-end=\"2527\" data-col-size=\"sm\" style=\"width: 23.9706%; height: 39.2px;\"\u003eInsulation \/ Dielectric Strength\u003c\/td\u003e\n\u003ctd data-start=\"2527\" data-end=\"2641\" data-col-size=\"lg\" style=\"width: 73.5695%; height: 39.2px;\"\u003eUsually meets standards (PC\/UL94-V0 case, insulation resistance, etc.) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2642\" data-end=\"2797\" style=\"height: 39.2px;\"\u003e\n\u003ctd data-start=\"2642\" data-end=\"2660\" data-col-size=\"sm\" style=\"width: 23.9706%; height: 39.2px;\"\u003eMechanical Type\u003c\/td\u003e\n\u003ctd data-start=\"2660\" data-end=\"2797\" data-col-size=\"lg\" style=\"width: 73.5695%; height: 39.2px;\"\u003eClamp \/ split core with self-locking mechanism, large window for bus-bars or thick conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2799\" data-end=\"2802\"\u003e\n\u003ch3 data-start=\"2804\" data-end=\"2820\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2822\" data-end=\"3200\"\u003e\n\u003cli data-start=\"2822\" data-end=\"2891\"\u003e\n\u003cp data-start=\"2824\" data-end=\"2891\"\u003eIndustrial \/ commercial power metering, energy management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2892\" data-end=\"2969\"\u003e\n\u003cp data-start=\"2894\" data-end=\"2969\"\u003eMonitoring high-load circuits: large motors, transformer feeders, busbars\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2970\" data-end=\"3039\"\u003e\n\u003cp data-start=\"2972\" data-end=\"3039\"\u003eProtection systems where accurate current measurement is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3040\" data-end=\"3127\"\u003e\n\u003cp data-start=\"3042\" data-end=\"3127\"\u003eRetrofit applications: open design allows installation without circuit interruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3128\" data-end=\"3200\"\u003e\n\u003cp data-start=\"3130\" data-end=\"3200\"\u003eIntegration with power analyzers, SCADA, building management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3202\" data-end=\"3205\"\u003e\n\u003ch3 data-start=\"3207\" data-end=\"3245\"\u003eInstallation \u0026amp; Safety Instructions\u003c\/h3\u003e\n\u003cul data-start=\"3247\" data-end=\"3799\"\u003e\n\u003cli data-start=\"3247\" data-end=\"3369\"\u003e\n\u003cp data-start=\"3249\" data-end=\"3369\"\u003eEnsure the conductor or busbar to be measured fits nicely through the 50×80 mm opening, without strain or deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3370\" data-end=\"3537\"\u003e\n\u003cp data-start=\"3372\" data-end=\"3537\"\u003e\u003cstrong data-start=\"3372\" data-end=\"3406\"\u003eNever leave the secondary open\u003c\/strong\u003e when the primary is energized — always connect a proper measurement device or load (meter \/ burden) to avoid dangerous voltages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3538\" data-end=\"3616\"\u003e\n\u003cp data-start=\"3540\" data-end=\"3616\"\u003eSecure the clamp fully; ensure locking mechanism engaged, stable mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3617\" data-end=\"3738\"\u003e\n\u003cp data-start=\"3619\" data-end=\"3738\"\u003eAvoid placing near strong external magnetic fields or in environments above the maximum rated temperature \/ moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3739\" data-end=\"3799\"\u003e\n\u003cp data-start=\"3741\" data-end=\"3799\"\u003eComply with local electrical standards and safety codes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3801\" data-end=\"3804\"\u003e\n\u003ch3 data-start=\"3806\" data-end=\"3818\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"3820\" data-end=\"4165\"\u003e\n\u003cli data-start=\"3820\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3822\" data-end=\"3925\"\u003eHigh accuracy (0.5%) improves measurement reliability, especially for billing, power quality, audits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4012\"\u003e\n\u003cp data-start=\"3928\" data-end=\"4012\"\u003eLarge aperture allows for thick cables or busbars without requiring modifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4013\" data-end=\"4090\"\u003e\n\u003cp data-start=\"4015\" data-end=\"4090\"\u003eSplit-core\/clamp design easing installation and reducing system downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4091\" data-end=\"4165\"\u003e\n\u003cp data-start=\"4093\" data-end=\"4165\"\u003eDurable materials and housing reduce maintenance and prolong lifespan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350746091811,"sku":null,"price":855.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/41LrJq-vLgL._AC_SX679.jpg?v=1758401246"},{"product_id":"lmhk-58-50-80-mm-window-clamp-split-core-current-transformer-2000-5a-accuracy-class-0-5","title":"LMHK-58 (50×80 mm Window) Clamp \/ Split-Core Current Transformer • 2000\/5A • Accuracy Class 0.5","description":"\u003ch2 data-start=\"1047\" data-end=\"1069\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"1071\" data-end=\"1085\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"1086\" data-end=\"1477\"\u003eThe \u003cstrong data-start=\"1090\" data-end=\"1128\"\u003eLMHK-58 2000\/5A Accuracy Class 0.5\u003c\/strong\u003e is a robust, high-capacity split-core current transformer designed for accurate measurement in heavy-duty electrical systems. With a primary current rating of \u003cstrong data-start=\"1288\" data-end=\"1301\"\u003e2000 A AC\u003c\/strong\u003e and secondary output of 5 A, combined with ±0.5% accuracy, this CT is ideal for precise energy monitoring, protection, and metering in commercial and industrial installations.\u003c\/p\u003e\n\u003chr data-start=\"1479\" data-end=\"1482\"\u003e\n\u003ch3 data-start=\"1484\" data-end=\"1500\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1502\" data-end=\"2324\"\u003e\n\u003cli data-start=\"1502\" data-end=\"1546\"\u003e\n\u003cp data-start=\"1504\" data-end=\"1546\"\u003e\u003cstrong data-start=\"1504\" data-end=\"1533\"\u003ePrimary : Secondary Ratio\u003c\/strong\u003e — 2000\/5 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1547\" data-end=\"1619\"\u003e\n\u003cp data-start=\"1549\" data-end=\"1619\"\u003e\u003cstrong data-start=\"1549\" data-end=\"1567\"\u003eAccuracy Class\u003c\/strong\u003e — 0.5, meaning ±0.5% error under rated conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1620\" data-end=\"1760\"\u003e\n\u003cp data-start=\"1622\" data-end=\"1760\"\u003e\u003cstrong data-start=\"1622\" data-end=\"1648\"\u003eWindow \/ Aperture Size\u003c\/strong\u003e — approx. \u003cstrong data-start=\"1659\" data-end=\"1671\"\u003e50×80 mm\u003c\/strong\u003e, meaning it accommodates large conductors or busbars without needing to open circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1761\" data-end=\"1862\"\u003e\n\u003cp data-start=\"1763\" data-end=\"1862\"\u003e\u003cstrong data-start=\"1763\" data-end=\"1781\"\u003eModel \/ Series\u003c\/strong\u003e — HK-58 from HEYI Electric (LMHK naming) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1863\" data-end=\"1990\"\u003e\n\u003cp data-start=\"1865\" data-end=\"1990\"\u003e\u003cstrong data-start=\"1865\" data-end=\"1881\"\u003eConstruction\u003c\/strong\u003e — Clamp \/ split-core type; can be mounted around existing conductors without disconnecting primary wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1991\" data-end=\"2153\"\u003e\n\u003cp data-start=\"1993\" data-end=\"2153\"\u003e\u003cstrong data-start=\"1993\" data-end=\"2017\"\u003eHousing and Material\u003c\/strong\u003e — Flame retardant plastic case (PC\/UL94-V0), core of silicon steel, internal epoxy \/ PBT parts. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2154\" data-end=\"2237\"\u003e\n\u003cp data-start=\"2156\" data-end=\"2237\"\u003e\u003cstrong data-start=\"2156\" data-end=\"2175\"\u003eFrequency Range\u003c\/strong\u003e — Typically 50-400 Hz \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2238\" data-end=\"2324\"\u003e\n\u003cp data-start=\"2240\" data-end=\"2324\"\u003e\u003cstrong data-start=\"2240\" data-end=\"2265\"\u003eOperating Temperature\u003c\/strong\u003e — −25 °C to +75 °C \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2326\" data-end=\"2329\"\u003e\n\u003ch3 data-start=\"2331\" data-end=\"2381\"\u003eOther Specifications (Typical \/ Supplier Data)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2383\" data-end=\"3216\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2383\" data-end=\"2418\"\u003e\n\u003ctr data-start=\"2383\" data-end=\"2418\"\u003e\n\u003cth data-start=\"2383\" data-end=\"2390\" data-col-size=\"sm\"\u003eSpec\u003c\/th\u003e\n\u003cth data-start=\"2390\" data-end=\"2418\" data-col-size=\"lg\"\u003eTypical \/ Expected Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2454\" data-end=\"3216\"\u003e\n\u003ctr data-start=\"2454\" data-end=\"2670\"\u003e\n\u003ctd data-start=\"2454\" data-end=\"2490\" data-col-size=\"sm\"\u003eBurden (VA) at Accuracy Class 0.5\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2490\" data-end=\"2670\"\u003eFor similar HK-58 models, burdens are often \u003cstrong data-start=\"2536\" data-end=\"2545\"\u003e10 VA\u003c\/strong\u003e for higher primary ratios (e.g. 800-1600 A); for 2000\/5A likely around \u003cstrong data-start=\"2617\" data-end=\"2629\"\u003e10-15 VA\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2671\" data-end=\"2804\"\u003e\n\u003ctd data-start=\"2671\" data-end=\"2689\" data-col-size=\"sm\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd data-start=\"2689\" data-end=\"2804\" data-col-size=\"lg\"\u003eUsually 10% In to ~120% In without large loss of accuracy (for HK series) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2805\" data-end=\"2957\"\u003e\n\u003ctd data-start=\"2805\" data-end=\"2839\" data-col-size=\"sm\"\u003eDielectric Strength \/ Isolation\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2839\" data-end=\"2957\"\u003eTypically around \u003cstrong data-start=\"2858\" data-end=\"2884\"\u003e2.5 kV AC for 1 minute\u003c\/strong\u003e test, much like other HK models. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2958\" data-end=\"3105\"\u003e\n\u003ctd data-start=\"2958\" data-end=\"2978\" data-col-size=\"sm\"\u003ePhase Angle Error\u003c\/td\u003e\n\u003ctd data-start=\"2978\" data-end=\"3105\" data-col-size=\"lg\"\u003eSmall; HK-series phase angle ≤ ±30 minutes (at rated current\/burden) in many specs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3106\" data-end=\"3216\"\u003e\n\u003ctd data-start=\"3106\" data-end=\"3130\" data-col-size=\"sm\"\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd data-start=\"3130\" data-end=\"3216\" data-col-size=\"lg\"\u003eDC 500 V, ≥ 100 MΩ for other HK-58 models. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3218\" data-end=\"3221\"\u003e\n\u003ch2 data-start=\"3223\" data-end=\"3238\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-start=\"3240\" data-end=\"3616\"\u003e\n\u003cli data-start=\"3240\" data-end=\"3365\"\u003e\n\u003cp data-start=\"3242\" data-end=\"3365\"\u003eLarge power panels, switchgear and distribution boards needing accurate current measurement for high loads (up to 2000 A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3366\" data-end=\"3444\"\u003e\n\u003cp data-start=\"3368\" data-end=\"3444\"\u003eIndustrial installations: motors, large transformers, busbars, substations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3445\" data-end=\"3519\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3519\"\u003eEnergy management systems, power metering, auditing, protection relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3520\" data-end=\"3616\"\u003e\n\u003cp data-start=\"3522\" data-end=\"3616\"\u003eRetrofit or upgrade works where wiring cannot be disconnected due to clamp\/split-core design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3618\" data-end=\"3621\"\u003e\n\u003ch2 data-start=\"3623\" data-end=\"3653\"\u003eInstallation \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul data-start=\"3655\" data-end=\"4115\"\u003e\n\u003cli data-start=\"3655\" data-end=\"3773\"\u003e\n\u003cp data-start=\"3657\" data-end=\"3773\"\u003eEnsure the conductor or busbar fits comfortably through the 50×80 mm window; avoid bending insulation or tight fit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3774\" data-end=\"3896\"\u003e\n\u003cp data-start=\"3776\" data-end=\"3896\"\u003eAlways connect secondary to the measurement device or burden; \u003cstrong data-start=\"3838\" data-end=\"3847\"\u003enever\u003c\/strong\u003e leave secondary open when primary is energized\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3897\" data-end=\"3975\"\u003e\n\u003cp data-start=\"3899\" data-end=\"3975\"\u003eClamp should be fully closed and locked; ensure proper mechanical mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3976\" data-end=\"4060\"\u003e\n\u003cp data-start=\"3978\" data-end=\"4060\"\u003eAvoid exposure to excessive moisture or environmental extremes beyond rated spec\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4061\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4063\" data-end=\"4115\"\u003eFollow local electrical and safety codes\/standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4133\"\u003eBenefits\u003c\/h2\u003e\n\u003cul data-start=\"4135\" data-end=\"4418\"\u003e\n\u003cli data-start=\"4135\" data-end=\"4192\"\u003e\n\u003cp data-start=\"4137\" data-end=\"4192\"\u003eHigh precision (0.5%) ideal for critical measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4193\" data-end=\"4273\"\u003e\n\u003cp data-start=\"4195\" data-end=\"4273\"\u003eLarge aperture allows use in high current systems without circuit disruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4274\" data-end=\"4341\"\u003e\n\u003cp data-start=\"4276\" data-end=\"4341\"\u003eClamp\/split-core design simplifies installation and maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4342\" data-end=\"4418\"\u003e\n\u003cp data-start=\"4344\" data-end=\"4418\"\u003eDurable with flame-retardant case, high insulation \u0026amp; dielectric strength\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350749991203,"sku":null,"price":1050.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/516sHWwn6OL._AC_SX679.jpg?v=1758401246"},{"product_id":"lmhk-612-60-120-mm-window-clamp-split-core-current-transformer-2500-5a-accuracy-class-0-5","title":"LMHK-612 (60×120 mm Window) Clamp \/ Split-Core Current Transformer • 2500\/5A • Accuracy Class 0.5","description":"\u003ch2 data-start=\"379\" data-end=\"401\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"403\" data-end=\"417\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"418\" data-end=\"927\"\u003eThe \u003cstrong data-start=\"422\" data-end=\"473\"\u003eLMHK-612 (60×120 mm) 2500\/5A Accuracy Class 0.5\u003c\/strong\u003e is a high-precision, open \/ clamp-on (split-core) current transformer designed for heavy-duty electrical monitoring applications. With a massive primary current rating of \u003cstrong data-start=\"645\" data-end=\"658\"\u003e2500 A AC\u003c\/strong\u003e and a standard \u003cstrong data-start=\"674\" data-end=\"681\"\u003e5 A\u003c\/strong\u003e secondary output, this CT provides \u003cstrong data-start=\"717\" data-end=\"735\"\u003e±0.5% accuracy\u003c\/strong\u003e under rated conditions. The large window (≈ 60×120 mm) allows it to accommodate large busbars or multiple conductors, making it ideal for industrial, commercial, or utility electrical panels.\u003c\/p\u003e\n\u003chr data-start=\"929\" data-end=\"932\"\u003e\n\u003ch3 data-start=\"934\" data-end=\"950\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"952\" data-end=\"1616\"\u003e\n\u003cli data-start=\"952\" data-end=\"984\"\u003e\n\u003cp data-start=\"954\" data-end=\"984\"\u003e\u003cstrong data-start=\"954\" data-end=\"972\"\u003eModel \/ Series\u003c\/strong\u003e: LMHK-612\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"985\" data-end=\"1031\"\u003e\n\u003cp data-start=\"987\" data-end=\"1031\"\u003e\u003cstrong data-start=\"987\" data-end=\"1018\"\u003ePrimary Current Rating (In)\u003c\/strong\u003e: 2500 A AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1032\" data-end=\"1107\"\u003e\n\u003cp data-start=\"1034\" data-end=\"1107\"\u003e\u003cstrong data-start=\"1034\" data-end=\"1067\"\u003eSecondary Current Rating (Is)\u003c\/strong\u003e: 5 A AC — transformation ratio 2500:5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1108\" data-end=\"1234\"\u003e\n\u003cp data-start=\"1110\" data-end=\"1234\"\u003e\u003cstrong data-start=\"1110\" data-end=\"1128\"\u003eAccuracy Class\u003c\/strong\u003e: 0.5 (Class 0.5) — high fidelity measurements suitable for billing, monitoring, and power quality tasks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1235\" data-end=\"1355\"\u003e\n\u003cp data-start=\"1237\" data-end=\"1355\"\u003e\u003cstrong data-start=\"1237\" data-end=\"1263\"\u003eWindow \/ Aperture Size\u003c\/strong\u003e: ~ \u003cstrong data-start=\"1267\" data-end=\"1280\"\u003e60×120 mm\u003c\/strong\u003e — this large opening is suitable for thick busbars or bundled conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1356\" data-end=\"1459\"\u003e\n\u003cp data-start=\"1358\" data-end=\"1459\"\u003e\u003cstrong data-start=\"1358\" data-end=\"1368\"\u003eDesign\u003c\/strong\u003e: Split-core \/ clamp-on style, allowing installation without breaking existing conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1460\" data-end=\"1616\"\u003e\n\u003cp data-start=\"1462\" data-end=\"1616\"\u003e\u003cstrong data-start=\"1462\" data-end=\"1485\"\u003eHousing \u0026amp; Materials\u003c\/strong\u003e: Flame-retardant plastic casing, moisture protection, durable core material; designed for stable performance and low maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1618\" data-end=\"1621\"\u003e\n\u003ch3 data-start=\"1623\" data-end=\"1672\"\u003eTechnical Specifications (Typical \/ Expected)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1674\" data-end=\"2418\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1674\" data-end=\"1711\"\u003e\n\u003ctr data-start=\"1674\" data-end=\"1711\"\u003e\n\u003cth data-start=\"1674\" data-end=\"1690\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1690\" data-end=\"1711\" data-col-size=\"md\"\u003eValue or Comments\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1774\" data-end=\"2418\"\u003e\n\u003ctr data-start=\"1774\" data-end=\"1816\"\u003e\n\u003ctd data-start=\"1774\" data-end=\"1802\" data-col-size=\"sm\"\u003ePrimary : Secondary Ratio\u003c\/td\u003e\n\u003ctd data-start=\"1802\" data-end=\"1816\" data-col-size=\"md\"\u003e2500 : 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1817\" data-end=\"1868\"\u003e\n\u003ctd data-start=\"1817\" data-end=\"1834\" data-col-size=\"sm\"\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd data-start=\"1834\" data-end=\"1868\" data-col-size=\"md\"\u003e0.5 (±0.5%) under rated burden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1869\" data-end=\"1913\"\u003e\n\u003ctd data-start=\"1869\" data-end=\"1887\" data-col-size=\"sm\"\u003eWindow Aperture\u003c\/td\u003e\n\u003ctd data-start=\"1887\" data-end=\"1913\" data-col-size=\"md\"\u003eApprox. 60 mm × 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1914\" data-end=\"1973\"\u003e\n\u003ctd data-start=\"1914\" data-end=\"1932\" data-col-size=\"sm\"\u003eRated Frequency\u003c\/td\u003e\n\u003ctd data-start=\"1932\" data-end=\"1973\" data-col-size=\"md\"\u003e50 \/ 60 Hz (verify with manufacturer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1974\" data-end=\"2094\"\u003e\n\u003ctd data-start=\"1974\" data-end=\"1996\" data-col-size=\"sm\"\u003eMaximum Burden (VA)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1996\" data-end=\"2094\"\u003eUsually in the order of 10-15 VA for transformers of this size and accuracy; must be confirmed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2095\" data-end=\"2224\"\u003e\n\u003ctd data-start=\"2095\" data-end=\"2130\" data-col-size=\"sm\"\u003eInsulation \/ Dielectric Strength\u003c\/td\u003e\n\u003ctd data-start=\"2130\" data-end=\"2224\" data-col-size=\"md\"\u003eHigh insulation, likely several kV for test rating; case designed to meet safety standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2225\" data-end=\"2297\"\u003e\n\u003ctd data-start=\"2225\" data-end=\"2259\" data-col-size=\"sm\"\u003eOperating \/ Ambient Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2259\" data-end=\"2297\" data-col-size=\"md\"\u003eExpected −25 °C to +75 °C (verify)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2298\" data-end=\"2418\"\u003e\n\u003ctd data-start=\"2298\" data-end=\"2324\" data-col-size=\"sm\"\u003eMounting \/ Installation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2324\" data-end=\"2418\"\u003eClamp \/ split-core type; ensure good mechanical fit and locking; secure mounting essential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2420\" data-end=\"2423\"\u003e\n\u003ch3 data-start=\"2425\" data-end=\"2441\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2443\" data-end=\"2784\"\u003e\n\u003cli data-start=\"2443\" data-end=\"2518\"\u003e\n\u003cp data-start=\"2445\" data-end=\"2518\"\u003eIndustrial switchgear and distribution boards with high current busbars\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2519\" data-end=\"2591\"\u003e\n\u003cp data-start=\"2521\" data-end=\"2591\"\u003eUtility metering \/ energy management in big commercial installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2592\" data-end=\"2694\"\u003e\n\u003cp data-start=\"2594\" data-end=\"2694\"\u003eAccurate power monitoring, billing, and power quality measurement where high currents are involved\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2695\" data-end=\"2784\"\u003e\n\u003cp data-start=\"2697\" data-end=\"2784\"\u003eRetrofit or upgrade jobs where the existing equipment or busbars cannot be dismantled\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2786\" data-end=\"2789\"\u003e\n\u003ch3 data-start=\"2791\" data-end=\"2822\"\u003eInstallation \u0026amp; Safety Notes\u003c\/h3\u003e\n\u003cul data-start=\"2824\" data-end=\"3494\"\u003e\n\u003cli data-start=\"2824\" data-end=\"2936\"\u003e\n\u003cp data-start=\"2826\" data-end=\"2936\"\u003eEnsure the conductors or busbars fit cleanly through the large aperture without causing damage to insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2937\" data-end=\"3116\"\u003e\n\u003cp data-start=\"2939\" data-end=\"3116\"\u003eAlways connect the secondary winding to a measuring instrument or burden resistor; \u003cstrong data-start=\"3022\" data-end=\"3031\"\u003enever\u003c\/strong\u003e leave secondary open when primary is energized — this can cause dangerous voltages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3117\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3119\" data-end=\"3216\"\u003eClamp must be fully closed, locked, and mechanically secure for accurate performance and safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3217\" data-end=\"3304\"\u003e\n\u003cp data-start=\"3219\" data-end=\"3304\"\u003eAvoid placing near strong external magnetic or electromagnetic interference sources\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3305\" data-end=\"3412\"\u003e\n\u003cp data-start=\"3307\" data-end=\"3412\"\u003eProtect the unit from environmental extremes (humidity, dust, high temperature) beyond its rated limits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3413\" data-end=\"3494\"\u003e\n\u003cp data-start=\"3415\" data-end=\"3494\"\u003eAdhere to local electrical codes, wiring, grounding, and insulation standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3496\" data-end=\"3499\"\u003e\n\u003ch3 data-start=\"3501\" data-end=\"3513\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"3515\" data-end=\"3851\"\u003e\n\u003cli data-start=\"3515\" data-end=\"3601\"\u003e\n\u003cp data-start=\"3517\" data-end=\"3601\"\u003eVery high current capacity (2500 A) in a compact design for large aperture systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3602\" data-end=\"3703\"\u003e\n\u003cp data-start=\"3604\" data-end=\"3703\"\u003eExcellent measurement accuracy (0.5%) — suitable for critical monitoring and billing applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3704\" data-end=\"3804\"\u003e\n\u003cp data-start=\"3706\" data-end=\"3804\"\u003eClamp-on \/ split-core design for easier installation \/ retrofitting without service interruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3805\" data-end=\"3851\"\u003e\n\u003cp data-start=\"3807\" data-end=\"3851\"\u003eDurable design with safety minded features\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350752612643,"sku":null,"price":1250.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/51eIP71nO-L._AC_SX679.jpg?v=1758401246"},{"product_id":"lmhk-612-60-120-mm-window-clamp-split-core-current-transformer-3000-5a-accuracy-class-0-5","title":"LMHK-612 (60×120 mm Window) Clamp \/ Split-Core Current Transformer • 3000\/5A • Accuracy Class 0.5","description":"\u003ch2 data-start=\"485\" data-end=\"507\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"509\" data-end=\"523\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"524\" data-end=\"1104\"\u003eThe \u003cstrong data-start=\"528\" data-end=\"567\"\u003eLMHK-612 3000\/5A Accuracy Class 0.5\u003c\/strong\u003e is a high-capacity current transformer designed for heavy electrical systems where precise measurement is needed. With a primary current rating of \u003cstrong data-start=\"715\" data-end=\"728\"\u003e3000 A AC\u003c\/strong\u003e and a secondary output of \u003cstrong data-start=\"755\" data-end=\"762\"\u003e5 A\u003c\/strong\u003e, coupled with \u003cstrong data-start=\"777\" data-end=\"795\"\u003e±0.5% accuracy\u003c\/strong\u003e, this CT is ideal for metering, monitoring, protection, and energy management in large commercial \/ industrial installations. The large aperture (approx. 60×120 mm) allows it to accommodate oversized conductors or busbars without the need to disconnect them — making installation simpler and less disruptive.\u003c\/p\u003e\n\u003chr data-start=\"1106\" data-end=\"1109\"\u003e\n\u003ch3 data-start=\"1111\" data-end=\"1127\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1129\" data-end=\"2040\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1163\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1163\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1150\"\u003ePrimary Current\u003c\/strong\u003e: 3000 A AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1164\" data-end=\"1221\"\u003e\n\u003cp data-start=\"1166\" data-end=\"1221\"\u003e\u003cstrong data-start=\"1166\" data-end=\"1187\"\u003eSecondary Current\u003c\/strong\u003e: 5 A AC — giving a 3000:5 ratio\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1222\" data-end=\"1300\"\u003e\n\u003cp data-start=\"1224\" data-end=\"1300\"\u003e\u003cstrong data-start=\"1224\" data-end=\"1242\"\u003eAccuracy Class\u003c\/strong\u003e: 0.5 (±0.5%) under rated load \/ within specified burden\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1301\" data-end=\"1402\"\u003e\n\u003cp data-start=\"1303\" data-end=\"1402\"\u003e\u003cstrong data-start=\"1303\" data-end=\"1335\"\u003eWindow (Inner Aperture) Size\u003c\/strong\u003e: ~ \u003cstrong data-start=\"1339\" data-end=\"1354\"\u003e60 × 120 mm\u003c\/strong\u003e — suitable for large busbars or cable bundles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1403\" data-end=\"1551\"\u003e\n\u003cp data-start=\"1405\" data-end=\"1551\"\u003e\u003cstrong data-start=\"1405\" data-end=\"1422\"\u003eType \/ Design\u003c\/strong\u003e: Split-core (clamp-on) style with release \/ clamp mechanism so it can be installed without shutting down the primary conductor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1552\" data-end=\"1734\"\u003e\n\u003cp data-start=\"1554\" data-end=\"1734\"\u003e\u003cstrong data-start=\"1554\" data-end=\"1577\"\u003eHousing \u0026amp; Materials\u003c\/strong\u003e: Typical HK-series materials — flame-retardant plastics (e.g. PC or similar, often UL94-V0 rated), appropriate core material (silicon steel or equivalent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1735\" data-end=\"1804\"\u003e\n\u003cp data-start=\"1737\" data-end=\"1804\"\u003e\u003cstrong data-start=\"1737\" data-end=\"1756\"\u003eFrequency Range\u003c\/strong\u003e: Generally \u003cstrong data-start=\"1768\" data-end=\"1781\"\u003e50-400 Hz\u003c\/strong\u003e (per HK-series spec)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1805\" data-end=\"1892\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1892\"\u003e\u003cstrong data-start=\"1807\" data-end=\"1840\"\u003eOperational Temperature Range\u003c\/strong\u003e: Approx. \u003cstrong data-start=\"1850\" data-end=\"1868\"\u003e−25°C to +75°C\u003c\/strong\u003e typical for HK models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1893\" data-end=\"2040\"\u003e\n\u003cp data-start=\"1895\" data-end=\"2040\"\u003e\u003cstrong data-start=\"1895\" data-end=\"1918\"\u003eInsulation \u0026amp; Safety\u003c\/strong\u003e: Dielectric strength around \u003cstrong data-start=\"1947\" data-end=\"1972\"\u003e2.5 kV \/ 1 mA \/ 1 min\u003c\/strong\u003e (or as per spec), good insulation resistance, moisture protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2042\" data-end=\"2045\"\u003e\n\u003ch3 data-start=\"2047\" data-end=\"2106\"\u003eTechnical Specifications (Expected \/ Comparable values)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2108\" data-end=\"2982\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2108\" data-end=\"2152\"\u003e\n\u003ctr data-start=\"2108\" data-end=\"2152\"\u003e\n\u003cth data-start=\"2108\" data-end=\"2124\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2124\" data-end=\"2152\" data-col-size=\"lg\"\u003eTypical \/ Expected Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2213\" data-end=\"2982\"\u003e\n\u003ctr data-start=\"2213\" data-end=\"2239\"\u003e\n\u003ctd data-start=\"2213\" data-end=\"2221\" data-col-size=\"sm\"\u003eRatio\u003c\/td\u003e\n\u003ctd data-start=\"2221\" data-end=\"2239\" data-col-size=\"lg\"\u003e\u003cstrong data-start=\"2223\" data-end=\"2237\"\u003e3000 : 5 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2240\" data-end=\"2277\"\u003e\n\u003ctd data-start=\"2240\" data-end=\"2257\" data-col-size=\"sm\"\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd data-start=\"2257\" data-end=\"2277\" data-col-size=\"lg\"\u003e\n\u003cstrong data-start=\"2259\" data-end=\"2267\"\u003e0.50\u003c\/strong\u003e (±0.5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2278\" data-end=\"2321\"\u003e\n\u003ctd data-start=\"2278\" data-end=\"2292\" data-col-size=\"sm\"\u003eWindow Size\u003c\/td\u003e\n\u003ctd data-start=\"2292\" data-end=\"2321\" data-col-size=\"lg\"\u003e~ 60 mm × 120 mm aperture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2322\" data-end=\"2415\"\u003e\n\u003ctd data-start=\"2322\" data-end=\"2336\" data-col-size=\"sm\"\u003eBurden (VA)\u003c\/td\u003e\n\u003ctd data-start=\"2336\" data-end=\"2415\" data-col-size=\"lg\"\u003eLikely \u003cstrong data-start=\"2345\" data-end=\"2354\"\u003e15 VA\u003c\/strong\u003e for class-0.5 at this level (but verify from manufacturer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2416\" data-end=\"2493\"\u003e\n\u003ctd data-start=\"2416\" data-end=\"2434\" data-col-size=\"sm\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd data-start=\"2434\" data-end=\"2493\" data-col-size=\"lg\"\u003eOften 10% In to ~120% In with small error in this class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2494\" data-end=\"2569\"\u003e\n\u003ctd data-start=\"2494\" data-end=\"2520\" data-col-size=\"sm\"\u003eDielectric Voltage Test\u003c\/td\u003e\n\u003ctd data-start=\"2520\" data-end=\"2569\" data-col-size=\"lg\"\u003e~2.5 kV AC for 1 minute (common in HK series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2570\" data-end=\"2694\"\u003e\n\u003ctd data-start=\"2570\" data-end=\"2582\" data-col-size=\"sm\"\u003eMaterials\u003c\/td\u003e\n\u003ctd data-start=\"2582\" data-end=\"2694\" data-col-size=\"lg\"\u003eFlame-retardant plastic housing, core of silicon steel, internal support epoxy or PBT bobbin \/ tie materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2695\" data-end=\"2796\"\u003e\n\u003ctd data-start=\"2695\" data-end=\"2707\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-start=\"2707\" data-end=\"2796\" data-col-size=\"lg\"\u003e50 \/ 60 Hz standard; spec may allow broader (up to 400 Hz) in some HK series variants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2797\" data-end=\"2851\"\u003e\n\u003ctd data-start=\"2797\" data-end=\"2821\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2821\" data-end=\"2851\" data-col-size=\"lg\"\u003e-25 °C to +75 °C (ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2852\" data-end=\"2982\"\u003e\n\u003ctd data-start=\"2852\" data-end=\"2885\" data-col-size=\"sm\"\u003eOutput Terminals \/ Connections\u003c\/td\u003e\n\u003ctd data-start=\"2885\" data-end=\"2982\" data-col-size=\"lg\"\u003eUsually screw\/screw-terminal \/ clamp type suitable for measurement devices or metering panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2984\" data-end=\"2987\"\u003e\n\u003ch3 data-start=\"2989\" data-end=\"3005\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"3007\" data-end=\"3385\"\u003e\n\u003cli data-start=\"3007\" data-end=\"3084\"\u003e\n\u003cp data-start=\"3009\" data-end=\"3084\"\u003eHigh current monitoring in large switchgear, transformer feeders, busbars\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3085\" data-end=\"3168\"\u003e\n\u003cp data-start=\"3087\" data-end=\"3168\"\u003ePrecision metering \/ energy management in industrial \/ commercial power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3169\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3171\" data-end=\"3309\"\u003eRetrofit projects where conductor continuity \/ uptime is important (split-core design allows installation without disconnecting primary)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3385\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3385\"\u003eUse in power quality, monitoring, protection and load balancing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3387\" data-end=\"3390\"\u003e\n\u003ch3 data-start=\"3392\" data-end=\"3423\"\u003eInstallation \u0026amp; Safety Notes\u003c\/h3\u003e\n\u003cul data-start=\"3425\" data-end=\"3987\"\u003e\n\u003cli data-start=\"3425\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3427\" data-end=\"3531\"\u003eEnsure busbars or conductors fit through the 60×120 mm aperture without bending or damaging insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3532\" data-end=\"3664\"\u003e\n\u003cp data-start=\"3534\" data-end=\"3664\"\u003eAlways connect secondary side to a measurement device or burden; \u003cstrong data-start=\"3599\" data-end=\"3608\"\u003enever\u003c\/strong\u003e leave secondary open when primary is carrying current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3665\" data-end=\"3770\"\u003e\n\u003cp data-start=\"3667\" data-end=\"3770\"\u003eClamp \/ split-core must be completely closed and secured to avoid measurement error and ensure safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3771\" data-end=\"3847\"\u003e\n\u003cp data-start=\"3773\" data-end=\"3847\"\u003eAvoid external magnetic fields or interference that can distort readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3848\" data-end=\"3987\"\u003e\n\u003cp data-start=\"3850\" data-end=\"3987\"\u003eKeep away from moisture, extreme temperatures beyond rated spec; ensure adequacy of insulation and enclosure per local electrical codes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3989\" data-end=\"3992\"\u003e\n\u003ch3 data-start=\"3994\" data-end=\"4006\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"4008\" data-end=\"4366\"\u003e\n\u003cli data-start=\"4008\" data-end=\"4113\"\u003e\n\u003cp data-start=\"4010\" data-end=\"4113\"\u003eHigh precision (0.5%) gives reliable readings essential for billing, auditing, or critical monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4114\" data-end=\"4205\"\u003e\n\u003cp data-start=\"4116\" data-end=\"4205\"\u003eLarge aperture allows handling of thick conductors or busbars without system disruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4206\" data-end=\"4281\"\u003e\n\u003cp data-start=\"4208\" data-end=\"4281\"\u003eSplit-core design enables easier and safer installation and maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4282\" data-end=\"4366\"\u003e\n\u003cp data-start=\"4284\" data-end=\"4366\"\u003eBuilt with durable materials and safety features, reducing long term maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350754447651,"sku":null,"price":1300.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/CE-HK-58-Clamp-Type-Split-Core-Current-Transformer-with-1200-5A.avif?v=1758401246"},{"product_id":"lmhk-612-60-120-mm-window-clamp-split-core-current-transformer-4000-5a-accuracy-class-0-5","title":"LMHK-612 (60×120 mm Window) Clamp \/ Split-Core Current Transformer • 4000\/5A • Accuracy Class 0.5","description":"\u003ch2 data-start=\"939\" data-end=\"961\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"963\" data-end=\"977\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"978\" data-end=\"1445\"\u003eThe \u003cstrong data-start=\"982\" data-end=\"1021\"\u003eLMHK-612 4000\/5A Accuracy Class 0.5\u003c\/strong\u003e is a high-capacity split-core current transformer, designed for accurate measurement of up to \u003cstrong data-start=\"1116\" data-end=\"1132\"\u003e4000 Amps AC\u003c\/strong\u003e in systems where large conductors or busbars are present. The 60×120 mm window makes it suitable for thick conductors or grouped busbars without requiring disconnection. Accuracy Class 0.5 ensures ±0.5% maximum error under rated conditions—ideal for precision monitoring, energy metering, or power quality tasks.\u003c\/p\u003e\n\u003chr data-start=\"1447\" data-end=\"1450\"\u003e\n\u003ch3 data-start=\"1452\" data-end=\"1468\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1470\" data-end=\"2146\"\u003e\n\u003cli data-start=\"1470\" data-end=\"1511\"\u003e\n\u003cp data-start=\"1472\" data-end=\"1511\"\u003e\u003cstrong data-start=\"1472\" data-end=\"1498\"\u003ePrimary Current Rating\u003c\/strong\u003e: 4000 A AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1512\" data-end=\"1575\"\u003e\n\u003cp data-start=\"1514\" data-end=\"1575\"\u003e\u003cstrong data-start=\"1514\" data-end=\"1542\"\u003eSecondary Current Rating\u003c\/strong\u003e: 5 A AC — gives a 4000:5 ratio\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1576\" data-end=\"1630\"\u003e\n\u003cp data-start=\"1578\" data-end=\"1630\"\u003e\u003cstrong data-start=\"1578\" data-end=\"1596\"\u003eAccuracy Class\u003c\/strong\u003e: 0.5 (±0.5%) under rated burden\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1631\" data-end=\"1734\"\u003e\n\u003cp data-start=\"1633\" data-end=\"1734\"\u003e\u003cstrong data-start=\"1633\" data-end=\"1659\"\u003eWindow \/ Aperture Size\u003c\/strong\u003e: Approx. \u003cstrong data-start=\"1669\" data-end=\"1684\"\u003e60 × 120 mm\u003c\/strong\u003e — large opening for busbars or large conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1735\" data-end=\"1856\"\u003e\n\u003cp data-start=\"1737\" data-end=\"1856\"\u003e\u003cstrong data-start=\"1737\" data-end=\"1747\"\u003eDesign\u003c\/strong\u003e: Split-core \/ clamp-on, allowing retrofit installation or installation without breaking primary conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1857\" data-end=\"1952\"\u003e\n\u003cp data-start=\"1859\" data-end=\"1952\"\u003e\u003cstrong data-start=\"1859\" data-end=\"1878\"\u003eFrequency Range\u003c\/strong\u003e: Typically 50 \/ 60 Hz (HK series) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1953\" data-end=\"2146\"\u003e\n\u003cp data-start=\"1955\" data-end=\"2146\"\u003e\u003cstrong data-start=\"1955\" data-end=\"1977\"\u003eHousing \u0026amp; Material\u003c\/strong\u003e: Flame-retardant plastics, epoxy \/ PBT internals (based on similar Heyi products) with good insulation and mechanical protection \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2148\" data-end=\"2151\"\u003e\n\u003ch3 data-start=\"2153\" data-end=\"2203\"\u003eAdditional Specifications (Typical \/ Expected)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2205\" data-end=\"3033\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2205\" data-end=\"2240\"\u003e\n\u003ctr data-start=\"2205\" data-end=\"2240\"\u003e\n\u003cth data-start=\"2205\" data-end=\"2221\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2221\" data-end=\"2240\" data-col-size=\"md\"\u003eValue \/ Typical\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2304\" data-end=\"3033\"\u003e\n\u003ctr data-start=\"2304\" data-end=\"2442\"\u003e\n\u003ctd data-start=\"2304\" data-end=\"2335\" data-col-size=\"sm\"\u003eBurden (VA)\u003c\/td\u003e\n\u003ctd data-start=\"2335\" data-end=\"2442\" data-col-size=\"md\"\u003e~ 15-30 VA typical for 4000\/5A in Class 0.5 HK \/ HK-812 style CTs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2443\" data-end=\"2600\"\u003e\n\u003ctd data-start=\"2443\" data-end=\"2474\" data-col-size=\"sm\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd data-start=\"2474\" data-end=\"2600\" data-col-size=\"md\"\u003eOften from ~10% of rated primary up to ~120% without large error (HK-series support) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2601\" data-end=\"2763\"\u003e\n\u003ctd data-start=\"2601\" data-end=\"2632\" data-col-size=\"sm\"\u003eDielectric \/ Insulation\u003c\/td\u003e\n\u003ctd data-start=\"2632\" data-end=\"2763\" data-col-size=\"md\"\u003eGood insulation; likely a dielectric test voltage of ~2.5 kV \/ 1 minute in many HK-models \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2764\" data-end=\"2891\"\u003e\n\u003ctd data-start=\"2764\" data-end=\"2795\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2795\" data-end=\"2891\" data-col-size=\"md\"\u003eTypically −25 °C to +75 °C (ambient) in Heyi HK models \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2892\" data-end=\"3033\"\u003e\n\u003ctd data-start=\"2892\" data-end=\"2923\" data-col-size=\"sm\"\u003ePhase Angle Error\u003c\/td\u003e\n\u003ctd data-start=\"2923\" data-end=\"3033\" data-col-size=\"md\"\u003eUsually small, ≤ ±30 minutes under rated conditions in HK series CTs \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3035\" data-end=\"3038\"\u003e\n\u003ch3 data-start=\"3040\" data-end=\"3067\"\u003eUse-Case \/ Applications\u003c\/h3\u003e\n\u003cul data-start=\"3069\" data-end=\"3421\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3155\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3155\"\u003eIndustrial switchgear, distribution boards with large busbars drawing high current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3156\" data-end=\"3233\"\u003e\n\u003cp data-start=\"3158\" data-end=\"3233\"\u003ePower monitoring \u0026amp; metering for large loads (motors, transformer feeders)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3234\" data-end=\"3319\"\u003e\n\u003cp data-start=\"3236\" data-end=\"3319\"\u003eEnergy management systems, power quality analysis, and protection instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3320\" data-end=\"3421\"\u003e\n\u003cp data-start=\"3322\" data-end=\"3421\"\u003eRetrofitting mature systems where shutting off or disconnecting primary conductors is problematic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3423\" data-end=\"3426\"\u003e\n\u003ch3 data-start=\"3428\" data-end=\"3459\"\u003eInstallation \u0026amp; Safety Notes\u003c\/h3\u003e\n\u003cul data-start=\"3461\" data-end=\"4128\"\u003e\n\u003cli data-start=\"3461\" data-end=\"3588\"\u003e\n\u003cp data-start=\"3463\" data-end=\"3588\"\u003eEnsure that the conductor(s) to pass through the 60×120 mm window fit cleanly, without bending insulation or causing strain\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3589\" data-end=\"3783\"\u003e\n\u003cp data-start=\"3591\" data-end=\"3783\"\u003eAlways terminate the secondary circuit to a measurement device or burden; \u003cstrong data-start=\"3665\" data-end=\"3726\"\u003enever leave the secondary open with the primary energized\u003c\/strong\u003e — open secondary can lead to dangerously high voltages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3784\" data-end=\"3926\"\u003e\n\u003cp data-start=\"3786\" data-end=\"3926\"\u003eSecure the clamp fully, ensure mechanical stability, avoid vibration or movement that could shift its position (which can affect accuracy)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3927\" data-end=\"4036\"\u003e\n\u003cp data-start=\"3929\" data-end=\"4036\"\u003eInstall in environment adhering to temperature, humidity, and electromagnetic standards of the spec sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4037\" data-end=\"4128\"\u003e\n\u003cp data-start=\"4039\" data-end=\"4128\"\u003eFollow local electrical safety codes, ensure sufficient insulation, proper wiring, etc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4130\" data-end=\"4133\"\u003e\n\u003ch3 data-start=\"4135\" data-end=\"4147\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"4149\" data-end=\"4454\"\u003e\n\u003cli data-start=\"4149\" data-end=\"4234\"\u003e\n\u003cp data-start=\"4151\" data-end=\"4234\"\u003ePrecise measurement with ±0.5% accuracy — good for billing and quality monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4235\" data-end=\"4330\"\u003e\n\u003cp data-start=\"4237\" data-end=\"4330\"\u003eLarge aperture size allows use with large conductors or busbars without disruptive rewiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4331\" data-end=\"4401\"\u003e\n\u003cp data-start=\"4333\" data-end=\"4401\"\u003eClamp\/on split-core design simplifies installation and maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4402\" data-end=\"4454\"\u003e\n\u003cp data-start=\"4404\" data-end=\"4454\"\u003eRobust design suited for industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54350758150435,"sku":null,"price":1400.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/s-l1200_8113c852-f6fe-449e-ab95-9502884341dd.jpg?v=1758401246"},{"product_id":"phoenix-contact-mm-ee-eem-em357-three-phase-energy-meter-100-a-rs-485-modbus-pulse-outputs","title":"Phoenix Contact MM-EE-EEM-EM357 Three-Phase Energy Meter 100 A RS-485 MODBUS Pulse Outputs","description":"\u003cp data-start=\"589\" data-end=\"1073\"\u003eThe \u003cstrong data-start=\"593\" data-end=\"647\"\u003ePhoenix Contact MM-EE-EEM-EM357 (Part No. 1744495)\u003c\/strong\u003e is a \u003cstrong data-start=\"653\" data-end=\"702\"\u003ethree-phase energy and power measuring device\u003c\/strong\u003e designed for industrial energy monitoring and control systems. It directly measures active power in \u003cstrong data-start=\"803\" data-end=\"842\"\u003ethree-phase networks up to 480 V AC\u003c\/strong\u003e and \u003cstrong data-start=\"847\" data-end=\"866\"\u003e100 A per phase\u003c\/strong\u003e with high precision, making it suitable for load tracking, efficiency monitoring, and power management in factories, commercial buildings, and industrial installations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1075\" data-end=\"1540\"\u003eFeaturing a \u003cstrong data-start=\"1087\" data-end=\"1132\"\u003eclear LCD display with white backlighting\u003c\/strong\u003e, the unit shows real-time energy values and other electrical parameters. It supports \u003cstrong data-start=\"1218\" data-end=\"1271\"\u003eModbus\/RTU communication over an RS-485 interface\u003c\/strong\u003e and provides \u003cstrong data-start=\"1285\" data-end=\"1320\"\u003etwo opto-isolated pulse outputs\u003c\/strong\u003e for integration with data loggers, building management systems, or automation controllers. The meter is \u003cstrong data-start=\"1425\" data-end=\"1442\"\u003eMID-certified\u003c\/strong\u003e for compliance with energy billing and reporting standards. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1542\" data-end=\"1799\"\u003eBuilt for robust performance, this DIN-rail-mount unit operates in a wide ambient temperature range up to \u003cstrong data-start=\"1648\" data-end=\"1658\"\u003e+70 °C\u003c\/strong\u003e, with \u003cstrong data-start=\"1665\" data-end=\"1727\"\u003eIP51 front protection and IP20 connection enclosure rating\u003c\/strong\u003e for safe, long-term installation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1801\" data-end=\"1826\"\u003e📌 Key Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1827\" data-end=\"2545\"\u003e\n\u003cli data-start=\"1827\" data-end=\"1883\"\u003e\n\u003cp data-start=\"1829\" data-end=\"1883\"\u003e\u003cstrong data-start=\"1829\" data-end=\"1839\"\u003eModel:\u003c\/strong\u003e Phoenix Contact MM-EE-EEM-EM357 (1744495)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1884\" data-end=\"1945\"\u003e\n\u003cp data-start=\"1886\" data-end=\"1945\"\u003e\u003cstrong data-start=\"1886\" data-end=\"1907\"\u003eMeasurement Type:\u003c\/strong\u003e Three-phase active energy and power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1946\" data-end=\"2017\"\u003e\n\u003cp data-start=\"1948\" data-end=\"2017\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1966\"\u003eVoltage Range:\u003c\/strong\u003e ~173 V–480 V AC (Ph-Ph) \/ ~100 V–276 V AC (Ph-N)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2018\" data-end=\"2088\"\u003e\n\u003cp data-start=\"2020\" data-end=\"2088\"\u003e\u003cstrong data-start=\"2020\" data-end=\"2038\"\u003eCurrent Range:\u003c\/strong\u003e Direct measurement up to \u003cstrong data-start=\"2064\" data-end=\"2076\"\u003e100 A AC\u003c\/strong\u003e per phase\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2089\" data-end=\"2143\"\u003e\n\u003cp data-start=\"2091\" data-end=\"2143\"\u003e\u003cstrong data-start=\"2091\" data-end=\"2105\"\u003eInterface:\u003c\/strong\u003e RS-485 with \u003cstrong data-start=\"2118\" data-end=\"2132\"\u003eModbus\/RTU\u003c\/strong\u003e protocol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2144\" data-end=\"2198\"\u003e\n\u003cp data-start=\"2146\" data-end=\"2198\"\u003e\u003cstrong data-start=\"2146\" data-end=\"2158\"\u003eOutputs:\u003c\/strong\u003e 2 passive opto-isolated pulse outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2199\" data-end=\"2240\"\u003e\n\u003cp data-start=\"2201\" data-end=\"2240\"\u003e\u003cstrong data-start=\"2201\" data-end=\"2213\"\u003eDisplay:\u003c\/strong\u003e LCD with white backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2241\" data-end=\"2305\"\u003e\n\u003cp data-start=\"2243\" data-end=\"2305\"\u003e\u003cstrong data-start=\"2243\" data-end=\"2262\"\u003eCertifications:\u003c\/strong\u003e \u003cstrong data-start=\"2263\" data-end=\"2280\"\u003eMID certified\u003c\/strong\u003e for energy measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2306\" data-end=\"2343\"\u003e\n\u003cp data-start=\"2308\" data-end=\"2343\"\u003e\u003cstrong data-start=\"2308\" data-end=\"2321\"\u003eMounting:\u003c\/strong\u003e DIN-rail compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2344\" data-end=\"2405\"\u003e\n\u003cp data-start=\"2346\" data-end=\"2405\"\u003e\u003cstrong data-start=\"2346\" data-end=\"2361\"\u003eProtection:\u003c\/strong\u003e \u003cstrong data-start=\"2362\" data-end=\"2378\"\u003eIP51 (front)\u003c\/strong\u003e \/ \u003cstrong data-start=\"2381\" data-end=\"2403\"\u003eIP20 (connections)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2406\" data-end=\"2446\"\u003e\n\u003cp data-start=\"2408\" data-end=\"2446\"\u003e\u003cstrong data-start=\"2408\" data-end=\"2427\"\u003eOperating Temp:\u003c\/strong\u003e −40 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2447\" data-end=\"2545\"\u003e\n\u003cp data-start=\"2449\" data-end=\"2545\"\u003e\u003cstrong data-start=\"2449\" data-end=\"2464\"\u003eConnection:\u003c\/strong\u003e Screw terminals for power \u0026amp; communications \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2547\" data-end=\"2689\"\u003eThis energy meter is ideal for \u003cstrong data-start=\"2578\" data-end=\"2604\"\u003epower usage monitoring\u003c\/strong\u003e, \u003cstrong data-start=\"2606\" data-end=\"2625\"\u003ebilling systems\u003c\/strong\u003e, \u003cstrong data-start=\"2627\" data-end=\"2650\"\u003eenergy optimization\u003c\/strong\u003e, and \u003cstrong data-start=\"2656\" data-end=\"2688\"\u003eindustrial energy dashboards\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54665645228323,"sku":null,"price":2500.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00203138_full_b408.jpg?v=1768858743"},{"product_id":"single-phase-energy-meter-rs-485-45a-mid-mm-ee-eem-em157-certified-1744499","title":"Single Phase Energy Meter RS-485 45A MID MM-EE-EEM-EM157 Certified 1744499","description":"\u003cp data-start=\"104\" data-end=\"920\"\u003eThe Phoenix Contact MM-EE-EEM-EM157 (Part No. 1744499) is a high-accuracy single-phase energy meter designed for active energy measurement in residential, commercial, and industrial applications. Featuring direct measurement up to 276 V AC and 45 A, this compact meter provides reliable monitoring of energy consumption without requiring external current transformers. Equipped with an RS-485 communication interface and two pulse outputs, it enables seamless integration into energy management, building automation, and industrial monitoring systems. Certified in accordance with the MID (Measuring Instruments Directive), the MM-EE-EEM-EM157 is suitable for billing-related energy measurement applications and delivers dependable performance in operating temperatures up to +70°C.\u003c\/p\u003e\n\u003cp data-start=\"922\" data-end=\"938\"\u003e\u003cstrong data-start=\"922\" data-end=\"938\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"939\" data-end=\"1430\"\u003e\n\u003cli data-section-id=\"1yd8v3t\" data-start=\"939\" data-end=\"977\"\u003ePhoenix Contact Part Number: 1744499\u003c\/li\u003e\n\u003cli data-section-id=\"152zz1i\" data-start=\"978\" data-end=\"1002\"\u003eModel: MM-EE-EEM-EM157\u003c\/li\u003e\n\u003cli data-section-id=\"jf57uh\" data-start=\"1003\" data-end=\"1030\"\u003eSingle-phase energy meter\u003c\/li\u003e\n\u003cli data-section-id=\"u5n7ik\" data-start=\"1031\" data-end=\"1058\"\u003eActive energy measurement\u003c\/li\u003e\n\u003cli data-section-id=\"99cd92\" data-start=\"1059\" data-end=\"1094\"\u003eDirect measurement up to 276 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"8ehbpv\" data-start=\"1095\" data-end=\"1118\"\u003eMaximum current: 45 A\u003c\/li\u003e\n\u003cli data-section-id=\"168vbh4\" data-start=\"1119\" data-end=\"1151\"\u003eRS-485 communication interface\u003c\/li\u003e\n\u003cli data-section-id=\"1dn2l2h\" data-start=\"1152\" data-end=\"1169\"\u003e2 pulse outputs\u003c\/li\u003e\n\u003cli data-section-id=\"xcupjv\" data-start=\"1170\" data-end=\"1210\"\u003eMID-certified for billing applications\u003c\/li\u003e\n\u003cli data-section-id=\"e1rjkh\" data-start=\"1211\" data-end=\"1238\"\u003eHigh measurement accuracy\u003c\/li\u003e\n\u003cli data-section-id=\"dtd314\" data-start=\"1239\" data-end=\"1274\"\u003eOperating temperature up to +70°C\u003c\/li\u003e\n\u003cli data-section-id=\"8r4rut\" data-start=\"1275\" data-end=\"1309\"\u003eCompact DIN rail mounting design\u003c\/li\u003e\n\u003cli data-section-id=\"16krpya\" data-start=\"1310\" data-end=\"1365\"\u003eSuitable for energy monitoring and management systems\u003c\/li\u003e\n\u003cli data-section-id=\"1wo6emx\" data-start=\"1366\" data-end=\"1430\"\u003eReliable performance in industrial and commercial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1432\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1432\" data-end=\"1448\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1449\" data-end=\"1724\"\u003e\n\u003cli data-section-id=\"mwoxqb\" data-start=\"1449\" data-end=\"1480\"\u003eEnergy consumption monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"12auq2\" data-start=\"1481\" data-end=\"1503\"\u003eUtility sub-metering\u003c\/li\u003e\n\u003cli data-section-id=\"1vpv2cm\" data-start=\"1504\" data-end=\"1539\"\u003eBuilding management systems (BMS)\u003c\/li\u003e\n\u003cli data-section-id=\"rb6wls\" data-start=\"1540\" data-end=\"1563\"\u003eIndustrial automation\u003c\/li\u003e\n\u003cli data-section-id=\"1d8qd5j\" data-start=\"1564\" data-end=\"1587\"\u003eCommercial facilities\u003c\/li\u003e\n\u003cli data-section-id=\"kezgvo\" data-start=\"1588\" data-end=\"1619\"\u003eResidential energy monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"agbpk8\" data-start=\"1620\" data-end=\"1647\"\u003ePower distribution panels\u003c\/li\u003e\n\u003cli data-section-id=\"1jzhixh\" data-start=\"1648\" data-end=\"1681\"\u003eEnergy management systems (EMS)\u003c\/li\u003e\n\u003cli data-section-id=\"1lkst22\" data-start=\"1682\" data-end=\"1724\"\u003eBilling and cost allocation applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":55170279407907,"sku":null,"price":1550.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00203136_full_b408.jpg?v=1780238511"},{"product_id":"current-transformer-250-5a-ct-es-30i-3010-60-250-5a-c05-class-0-5-1075955","title":"Current Transformer 250\/5A CT-ES-30I-3010-60-250-5A-C05  Class 0.5 1075955","description":"\u003cp data-start=\"103\" data-end=\"878\"\u003eThe Phoenix Contact CT-ES-30I-3010-60-250-5A-C05 (Part No. 1075955) is a high-accuracy window-type current transformer designed for precise current measurement and monitoring in industrial power distribution and energy management systems. Featuring a primary current rating of 250 A AC and a secondary output of 5 A AC, this transformer is ideal for use with energy meters, power analyzers, and protection devices. With accuracy class 0.5 and a rated burden of 5 VA, it delivers reliable and accurate measurement performance for commercial and industrial applications. Its compact window-type design enables easy installation around existing conductors, making it suitable for switchboards, control panels, and electrical monitoring systems.\u003c\/p\u003e\n\u003cp data-start=\"880\" data-end=\"896\"\u003e\u003cstrong data-start=\"880\" data-end=\"896\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"897\" data-end=\"1343\"\u003e\n\u003cli data-section-id=\"1xung8h\" data-start=\"897\" data-end=\"935\"\u003ePhoenix Contact Part Number: 1075955\u003c\/li\u003e\n\u003cli data-section-id=\"fvtwyi\" data-start=\"936\" data-end=\"973\"\u003eModel: CT-ES-30I-3010-60-250-5A-C05\u003c\/li\u003e\n\u003cli data-section-id=\"1gfrgf7\" data-start=\"974\" data-end=\"1007\"\u003eWindow-type current transformer\u003c\/li\u003e\n\u003cli data-section-id=\"gitq4j\" data-start=\"1008\" data-end=\"1035\"\u003ePrimary current: 250 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"12qeion\" data-start=\"1036\" data-end=\"1063\"\u003eSecondary current: 5 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"wadxzq\" data-start=\"1064\" data-end=\"1088\"\u003eCurrent ratio: 250\/5 A\u003c\/li\u003e\n\u003cli data-section-id=\"1clxtu2\" data-start=\"1089\" data-end=\"1110\"\u003eAccuracy class: 0.5\u003c\/li\u003e\n\u003cli data-section-id=\"1qabbdo\" data-start=\"1111\" data-end=\"1131\"\u003eRated burden: 5 VA\u003c\/li\u003e\n\u003cli data-section-id=\"1w1c8fn\" data-start=\"1132\" data-end=\"1183\"\u003eSuitable for energy metering and power monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"fw8dtn\" data-start=\"1184\" data-end=\"1211\"\u003eCompact and robust design\u003c\/li\u003e\n\u003cli data-section-id=\"1u2y3rn\" data-start=\"1212\" data-end=\"1249\"\u003eEasy installation around conductors\u003c\/li\u003e\n\u003cli data-section-id=\"1wbxmz\" data-start=\"1250\" data-end=\"1292\"\u003eReliable current measurement performance\u003c\/li\u003e\n\u003cli data-section-id=\"15uy77z\" data-start=\"1293\" data-end=\"1343\"\u003eIdeal for industrial and commercial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1345\" data-end=\"1361\"\u003e\u003cstrong data-start=\"1345\" data-end=\"1361\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1362\" data-end=\"1640\"\u003e\n\u003cli data-section-id=\"114lgxj\" data-start=\"1362\" data-end=\"1387\"\u003eEnergy metering systems\u003c\/li\u003e\n\u003cli data-section-id=\"a6dsq9\" data-start=\"1388\" data-end=\"1416\"\u003ePower monitoring equipment\u003c\/li\u003e\n\u003cli data-section-id=\"rb6wls\" data-start=\"1417\" data-end=\"1440\"\u003eIndustrial automation\u003c\/li\u003e\n\u003cli data-section-id=\"1o1s2rf\" data-start=\"1441\" data-end=\"1470\"\u003eBuilding management systems\u003c\/li\u003e\n\u003cli data-section-id=\"ote5mv\" data-start=\"1471\" data-end=\"1509\"\u003eSwitchboards and distribution panels\u003c\/li\u003e\n\u003cli data-section-id=\"1s767u\" data-start=\"1510\" data-end=\"1542\"\u003eElectrical measurement systems\u003c\/li\u003e\n\u003cli data-section-id=\"c0rhxy\" data-start=\"1543\" data-end=\"1569\"\u003ePower quality monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"5irm6i\" data-start=\"1570\" data-end=\"1601\"\u003eIndustrial power distribution\u003c\/li\u003e\n\u003cli data-section-id=\"raaehc\" data-start=\"1602\" data-end=\"1640\"\u003eUtility and commercial installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":55170301985059,"sku":null,"price":185.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00007603_full_b408.jpg?v=1780239485"},{"product_id":"current-transformer-800-5a-ct-es-40i-4010-75-800-5a-c05-class-0-5-10va-1076175","title":"Current Transformer 800\/5A CT-ES-40I-4010-75-800-5A-C05 Class 0.5 10VA 1076175","description":"\u003cp data-start=\"108\" data-end=\"909\"\u003eThe Phoenix Contact CT-ES-40I-4010-75-800-5A-C05 (Part No. 1076175) is a precision window-type current transformer engineered for accurate current measurement in industrial, commercial, and power distribution applications. Designed with an 800 A AC primary current rating and a 5 A AC secondary output, this transformer provides a reliable 800\/5 A conversion ratio for use with energy meters, power analyzers, monitoring systems, and protection relays. With an accuracy class of 0.5 and a rated burden of 10 VA, it ensures dependable measurement performance for energy management and electrical monitoring. The window-type construction allows quick installation around conductors, making it ideal for switchboards, control panels, and electrical distribution systems.\u003c\/p\u003e\n\u003cp data-start=\"911\" data-end=\"927\"\u003e\u003cstrong data-start=\"911\" data-end=\"927\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"928\" data-end=\"1386\"\u003e\n\u003cli data-section-id=\"1xure6w\" data-start=\"928\" data-end=\"966\"\u003ePhoenix Contact Part Number: 1076175\u003c\/li\u003e\n\u003cli data-section-id=\"1rkt2p\" data-start=\"967\" data-end=\"1004\"\u003eModel: CT-ES-40I-4010-75-800-5A-C05\u003c\/li\u003e\n\u003cli data-section-id=\"1gfrgf7\" data-start=\"1005\" data-end=\"1038\"\u003eWindow-type current transformer\u003c\/li\u003e\n\u003cli data-section-id=\"1303fbg\" data-start=\"1039\" data-end=\"1066\"\u003ePrimary current: 800 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"12qeion\" data-start=\"1067\" data-end=\"1094\"\u003eSecondary current: 5 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"188a649\" data-start=\"1095\" data-end=\"1119\"\u003eCurrent ratio: 800\/5 A\u003c\/li\u003e\n\u003cli data-section-id=\"1clxtu2\" data-start=\"1120\" data-end=\"1141\"\u003eAccuracy class: 0.5\u003c\/li\u003e\n\u003cli data-section-id=\"1uob4i0\" data-start=\"1142\" data-end=\"1163\"\u003eRated burden: 10 VA\u003c\/li\u003e\n\u003cli data-section-id=\"ed6bge\" data-start=\"1164\" data-end=\"1200\"\u003eHigh-precision current measurement\u003c\/li\u003e\n\u003cli data-section-id=\"fdbbyy\" data-start=\"1201\" data-end=\"1254\"\u003eSuitable for energy metering and monitoring systems\u003c\/li\u003e\n\u003cli data-section-id=\"10burtc\" data-start=\"1255\" data-end=\"1289\"\u003eCompact and durable construction\u003c\/li\u003e\n\u003cli data-section-id=\"h9guxs\" data-start=\"1290\" data-end=\"1336\"\u003eEasy installation around existing conductors\u003c\/li\u003e\n\u003cli data-section-id=\"1uvnudq\" data-start=\"1337\" data-end=\"1386\"\u003eReliable performance in industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1388\" data-end=\"1404\"\u003e\u003cstrong data-start=\"1388\" data-end=\"1404\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1405\" data-end=\"1709\"\u003e\n\u003cli data-section-id=\"114lgxj\" data-start=\"1405\" data-end=\"1430\"\u003eEnergy metering systems\u003c\/li\u003e\n\u003cli data-section-id=\"1obhnoi\" data-start=\"1431\" data-end=\"1462\"\u003ePower monitoring and analysis\u003c\/li\u003e\n\u003cli data-section-id=\"rb6wls\" data-start=\"1463\" data-end=\"1486\"\u003eIndustrial automation\u003c\/li\u003e\n\u003cli data-section-id=\"1vpv2cm\" data-start=\"1487\" data-end=\"1522\"\u003eBuilding management systems (BMS)\u003c\/li\u003e\n\u003cli data-section-id=\"zu8o49\" data-start=\"1523\" data-end=\"1555\"\u003eElectrical distribution panels\u003c\/li\u003e\n\u003cli data-section-id=\"ws28a4\" data-start=\"1556\" data-end=\"1596\"\u003eSwitchboards and motor control centers\u003c\/li\u003e\n\u003cli data-section-id=\"c0rhxy\" data-start=\"1597\" data-end=\"1623\"\u003ePower quality monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"4lexv5\" data-start=\"1624\" data-end=\"1656\"\u003eProtection and control systems\u003c\/li\u003e\n\u003cli data-section-id=\"vgs2rd\" data-start=\"1657\" data-end=\"1709\"\u003eCommercial and industrial electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":55170304966947,"sku":null,"price":280.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00007603_full_b408_5af0e33a-14a3-4ecb-b300-5dc3c3a147b3.jpg?v=1780239652"},{"product_id":"current-transformer-150-5a-ct-es-30i-3010-60-150-5a-c05-class-0-5-2-5va-1075968","title":"Current Transformer 150\/5A CT-ES-30I-3010-60-150-5A-C05  Class 0.5 2.5VA 1075968","description":"\u003cp data-start=\"109\" data-end=\"902\"\u003eThe Phoenix Contact CT-ES-30I-3010-60-150-5A-C05 (Part No. 1075968) is a high-precision window-type current transformer designed for accurate current measurement in industrial, commercial, and energy management applications. Featuring a primary current rating of 150 A AC and a secondary output of 5 A AC, this transformer provides a reliable 150\/5 A conversion ratio for use with energy meters, power analyzers, monitoring devices, and protection systems. With an accuracy class of 0.5 and a rated burden of 2.5 VA, it ensures dependable measurement performance while maintaining compact dimensions. The window-type design allows simple installation around conductors, making it ideal for switchboards, distribution panels, and electrical monitoring systems.\u003c\/p\u003e\n\u003cp data-start=\"904\" data-end=\"920\"\u003e\u003cstrong data-start=\"904\" data-end=\"920\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"921\" data-end=\"1368\"\u003e\n\u003cli data-section-id=\"1xung9r\" data-start=\"921\" data-end=\"959\"\u003ePhoenix Contact Part Number: 1075968\u003c\/li\u003e\n\u003cli data-section-id=\"1ro1wxl\" data-start=\"960\" data-end=\"997\"\u003eModel: CT-ES-30I-3010-60-150-5A-C05\u003c\/li\u003e\n\u003cli data-section-id=\"1gfrgf7\" data-start=\"998\" data-end=\"1031\"\u003eWindow-type current transformer\u003c\/li\u003e\n\u003cli data-section-id=\"z80bz4\" data-start=\"1032\" data-end=\"1059\"\u003ePrimary current: 150 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"12qeion\" data-start=\"1060\" data-end=\"1087\"\u003eSecondary current: 5 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"1thxiz9\" data-start=\"1088\" data-end=\"1112\"\u003eCurrent ratio: 150\/5 A\u003c\/li\u003e\n\u003cli data-section-id=\"1clxtu2\" data-start=\"1113\" data-end=\"1134\"\u003eAccuracy class: 0.5\u003c\/li\u003e\n\u003cli data-section-id=\"1w68dj4\" data-start=\"1135\" data-end=\"1157\"\u003eRated burden: 2.5 VA\u003c\/li\u003e\n\u003cli data-section-id=\"979i9h\" data-start=\"1158\" data-end=\"1193\"\u003eHigh-accuracy current measurement\u003c\/li\u003e\n\u003cli data-section-id=\"140ayhz\" data-start=\"1194\" data-end=\"1245\"\u003eSuitable for metering and monitoring applications\u003c\/li\u003e\n\u003cli data-section-id=\"10burtc\" data-start=\"1246\" data-end=\"1280\"\u003eCompact and durable construction\u003c\/li\u003e\n\u003cli data-section-id=\"1u2y3rn\" data-start=\"1281\" data-end=\"1318\"\u003eEasy installation around conductors\u003c\/li\u003e\n\u003cli data-section-id=\"1uvnudq\" data-start=\"1319\" data-end=\"1368\"\u003eReliable performance in industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1370\" data-end=\"1386\"\u003e\u003cstrong data-start=\"1370\" data-end=\"1386\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1387\" data-end=\"1674\"\u003e\n\u003cli data-section-id=\"114lgxj\" data-start=\"1387\" data-end=\"1412\"\u003eEnergy metering systems\u003c\/li\u003e\n\u003cli data-section-id=\"a6dsq9\" data-start=\"1413\" data-end=\"1441\"\u003ePower monitoring equipment\u003c\/li\u003e\n\u003cli data-section-id=\"rb6wls\" data-start=\"1442\" data-end=\"1465\"\u003eIndustrial automation\u003c\/li\u003e\n\u003cli data-section-id=\"1vpv2cm\" data-start=\"1466\" data-end=\"1501\"\u003eBuilding management systems (BMS)\u003c\/li\u003e\n\u003cli data-section-id=\"zu8o49\" data-start=\"1502\" data-end=\"1534\"\u003eElectrical distribution panels\u003c\/li\u003e\n\u003cli data-section-id=\"i46eqi\" data-start=\"1535\" data-end=\"1568\"\u003eSwitchboards and control panels\u003c\/li\u003e\n\u003cli data-section-id=\"c0rhxy\" data-start=\"1569\" data-end=\"1595\"\u003ePower quality monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"rbldgc\" data-start=\"1596\" data-end=\"1632\"\u003eProtection and measurement systems\u003c\/li\u003e\n\u003cli data-section-id=\"xu1nvb\" data-start=\"1633\" data-end=\"1674\"\u003eCommercial and industrial installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":55170309587235,"sku":null,"price":180.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00007603_full_b408_79f05b61-3602-4c59-9ca2-848db3eb593b.jpg?v=1780239931"},{"product_id":"current-transformer-600-5a-ct-es-40i-4010-75-600-5a-c05-class-0-5-10va-1076172","title":"Current Transformer 600\/5A CT-ES-40I-4010-75-600-5A-C05 Class 0.5 10VA 1076172","description":"\u003cp data-start=\"108\" data-end=\"920\"\u003eThe Phoenix Contact CT-ES-40I-4010-75-600-5A-C05 (Part No. 1076172) is a precision window-type current transformer designed for accurate current measurement in industrial power distribution, energy management, and monitoring applications. With a primary current rating of 600 A AC and a secondary output of 5 A AC, it provides a reliable 600\/5 A transformation ratio for use with energy meters, power analyzers, and protection devices. Featuring accuracy class 0.5 and a rated burden of 10 VA, this current transformer delivers dependable measurement performance for demanding industrial and commercial installations. Its window-type design allows quick installation around conductors, making it ideal for switchboards, motor control centers, and electrical distribution panels.\u003c\/p\u003e\n\u003cp data-start=\"922\" data-end=\"938\"\u003e\u003cstrong data-start=\"922\" data-end=\"938\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"939\" data-end=\"1401\"\u003e\n\u003cli data-section-id=\"1xure73\" data-start=\"939\" data-end=\"977\"\u003ePhoenix Contact Part Number: 1076172\u003c\/li\u003e\n\u003cli data-section-id=\"9k5fj\" data-start=\"978\" data-end=\"1015\"\u003eModel: CT-ES-40I-4010-75-600-5A-C05\u003c\/li\u003e\n\u003cli data-section-id=\"1gfrgf7\" data-start=\"1016\" data-end=\"1049\"\u003eWindow-type current transformer\u003c\/li\u003e\n\u003cli data-section-id=\"18nv2wy\" data-start=\"1050\" data-end=\"1077\"\u003ePrimary current: 600 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"12qeion\" data-start=\"1078\" data-end=\"1105\"\u003eSecondary current: 5 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"18pl6yf\" data-start=\"1106\" data-end=\"1130\"\u003eCurrent ratio: 600\/5 A\u003c\/li\u003e\n\u003cli data-section-id=\"1clxtu2\" data-start=\"1131\" data-end=\"1152\"\u003eAccuracy class: 0.5\u003c\/li\u003e\n\u003cli data-section-id=\"1uob4i0\" data-start=\"1153\" data-end=\"1174\"\u003eRated burden: 10 VA\u003c\/li\u003e\n\u003cli data-section-id=\"979i9h\" data-start=\"1175\" data-end=\"1210\"\u003eHigh-accuracy current measurement\u003c\/li\u003e\n\u003cli data-section-id=\"w7usy4\" data-start=\"1211\" data-end=\"1256\"\u003eSuitable for energy metering and monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"tqlw0v\" data-start=\"1257\" data-end=\"1289\"\u003eRobust industrial construction\u003c\/li\u003e\n\u003cli data-section-id=\"h9guxs\" data-start=\"1290\" data-end=\"1336\"\u003eEasy installation around existing conductors\u003c\/li\u003e\n\u003cli data-section-id=\"4j8yux\" data-start=\"1337\" data-end=\"1401\"\u003eReliable performance in commercial and industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1403\" data-end=\"1419\"\u003e\u003cstrong data-start=\"1403\" data-end=\"1419\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1420\" data-end=\"1713\"\u003e\n\u003cli data-section-id=\"114lgxj\" data-start=\"1420\" data-end=\"1445\"\u003eEnergy metering systems\u003c\/li\u003e\n\u003cli data-section-id=\"1obhnoi\" data-start=\"1446\" data-end=\"1477\"\u003ePower monitoring and analysis\u003c\/li\u003e\n\u003cli data-section-id=\"rb6wls\" data-start=\"1478\" data-end=\"1501\"\u003eIndustrial automation\u003c\/li\u003e\n\u003cli data-section-id=\"1vpv2cm\" data-start=\"1502\" data-end=\"1537\"\u003eBuilding management systems (BMS)\u003c\/li\u003e\n\u003cli data-section-id=\"zu8o49\" data-start=\"1538\" data-end=\"1570\"\u003eElectrical distribution panels\u003c\/li\u003e\n\u003cli data-section-id=\"17ubcts\" data-start=\"1571\" data-end=\"1600\"\u003eMotor control centers (MCC)\u003c\/li\u003e\n\u003cli data-section-id=\"c0rhxy\" data-start=\"1601\" data-end=\"1627\"\u003ePower quality monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"4lexv5\" data-start=\"1628\" data-end=\"1660\"\u003eProtection and control systems\u003c\/li\u003e\n\u003cli data-section-id=\"vgs2rd\" data-start=\"1661\" data-end=\"1713\"\u003eCommercial and industrial electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":55170312896803,"sku":null,"price":270.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00007603_full_b408_5af0e33a-14a3-4ecb-b300-5dc3c3a147b3.jpg?v=1780239652"},{"product_id":"current-transformer-1000-5a-ct-es-60ii-6010-98-1000-5a-c02-class-0-2-15va-1076370","title":"Current Transformer 1000\/5A CT-ES-60II-6010-98-1000-5A-C02 Class 0.2 15VA 1076370","description":"\u003cp data-start=\"111\" data-end=\"906\"\u003eThe Phoenix Contact CT-ES-60II-6010-98-1000-5A-C02 (Part No. 1076370) is a high-precision window-type current transformer designed for revenue-grade energy metering, power monitoring, and industrial measurement applications. Featuring a primary current rating of 1000 A AC and a secondary output of 5 A AC, it provides an accurate 1000\/5 A transformation ratio for use with energy meters, power analyzers, and monitoring equipment. With a superior accuracy class of 0.2 and a rated burden of 15 VA, this transformer delivers exceptional measurement accuracy for critical metering and energy management systems. The robust window-type construction enables easy installation around conductors in switchboards, motor control centers, and power distribution panels.\u003c\/p\u003e\n\u003cp data-start=\"908\" data-end=\"924\"\u003e\u003cstrong data-start=\"908\" data-end=\"924\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"925\" data-end=\"1436\"\u003e\n\u003cli data-section-id=\"1xurcm7\" data-start=\"925\" data-end=\"963\"\u003ePhoenix Contact Part Number: 1076370\u003c\/li\u003e\n\u003cli data-section-id=\"1uc8a9x\" data-start=\"964\" data-end=\"1003\"\u003eModel: CT-ES-60II-6010-98-1000-5A-C02\u003c\/li\u003e\n\u003cli data-section-id=\"1gfrgf7\" data-start=\"1004\" data-end=\"1037\"\u003eWindow-type current transformer\u003c\/li\u003e\n\u003cli data-section-id=\"10i37md\" data-start=\"1038\" data-end=\"1066\"\u003ePrimary current: 1000 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"12qeion\" data-start=\"1067\" data-end=\"1094\"\u003eSecondary current: 5 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"8er38g\" data-start=\"1095\" data-end=\"1120\"\u003eCurrent ratio: 1000\/5 A\u003c\/li\u003e\n\u003cli data-section-id=\"1clxtu5\" data-start=\"1121\" data-end=\"1142\"\u003eAccuracy class: 0.2\u003c\/li\u003e\n\u003cli data-section-id=\"1uo8rxp\" data-start=\"1143\" data-end=\"1164\"\u003eRated burden: 15 VA\u003c\/li\u003e\n\u003cli data-section-id=\"1an1d66\" data-start=\"1165\" data-end=\"1202\"\u003eHigh-precision metering performance\u003c\/li\u003e\n\u003cli data-section-id=\"tz9i20\" data-start=\"1203\" data-end=\"1250\"\u003eSuitable for revenue-grade energy measurement\u003c\/li\u003e\n\u003cli data-section-id=\"tqlw0v\" data-start=\"1251\" data-end=\"1283\"\u003eRobust industrial construction\u003c\/li\u003e\n\u003cli data-section-id=\"h9guxs\" data-start=\"1284\" data-end=\"1330\"\u003eEasy installation around existing conductors\u003c\/li\u003e\n\u003cli data-section-id=\"1axkx2b\" data-start=\"1331\" data-end=\"1377\"\u003eReliable operation in demanding environments\u003c\/li\u003e\n\u003cli data-section-id=\"1146wsp\" data-start=\"1378\" data-end=\"1436\"\u003eIdeal for power monitoring and energy management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1438\" data-end=\"1454\"\u003e\u003cstrong data-start=\"1438\" data-end=\"1454\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1455\" data-end=\"1771\"\u003e\n\u003cli data-section-id=\"1bexiqr\" data-start=\"1455\" data-end=\"1486\"\u003eRevenue-grade energy metering\u003c\/li\u003e\n\u003cli data-section-id=\"1oprzil\" data-start=\"1487\" data-end=\"1513\"\u003ePower monitoring systems\u003c\/li\u003e\n\u003cli data-section-id=\"1jzhixh\" data-start=\"1514\" data-end=\"1547\"\u003eEnergy management systems (EMS)\u003c\/li\u003e\n\u003cli data-section-id=\"rb6wls\" data-start=\"1548\" data-end=\"1571\"\u003eIndustrial automation\u003c\/li\u003e\n\u003cli data-section-id=\"1vpv2cm\" data-start=\"1572\" data-end=\"1607\"\u003eBuilding management systems (BMS)\u003c\/li\u003e\n\u003cli data-section-id=\"zu8o49\" data-start=\"1608\" data-end=\"1640\"\u003eElectrical distribution panels\u003c\/li\u003e\n\u003cli data-section-id=\"17ubcts\" data-start=\"1641\" data-end=\"1670\"\u003eMotor control centers (MCC)\u003c\/li\u003e\n\u003cli data-section-id=\"8odnfu\" data-start=\"1671\" data-end=\"1702\"\u003eUtility metering applications\u003c\/li\u003e\n\u003cli data-section-id=\"c0rhxy\" data-start=\"1703\" data-end=\"1729\"\u003ePower quality monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"xu1nvb\" data-start=\"1730\" data-end=\"1771\"\u003eCommercial and industrial installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":55170323448099,"sku":null,"price":550.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00007603_full_b408_79f05b61-3602-4c59-9ca2-848db3eb593b.jpg?v=1780239931"},{"product_id":"current-transformer-1500-5a-ct-es-60ii-6010-98-1500-5a-c02-class-0-2-20va-1076374","title":"Current Transformer 1500\/5A CT-ES-60II-6010-98-1500-5A-C02 Class 0.2 20VA 1076374","description":"\u003cp data-start=\"111\" data-end=\"943\"\u003eThe Phoenix Contact CT-ES-60II-6010-98-1500-5A-C02 (Part No. 1076374) is a premium window-type current transformer engineered for high-accuracy current measurement in power distribution, energy management, and revenue metering applications. Designed with a primary current rating of 1500 A AC and a secondary output of 5 A AC, it provides a precise 1500\/5 A transformation ratio for integration with energy meters, power analyzers, and monitoring systems. Featuring an exceptional accuracy class of 0.2 and a rated burden of 20 VA, this transformer delivers superior measurement performance in demanding industrial and commercial environments. Its window-type design enables straightforward installation around conductors in switchboards, motor control centers, and electrical distribution systems.\u003c\/p\u003e\n\u003cp data-start=\"945\" data-end=\"961\"\u003e\u003cstrong data-start=\"945\" data-end=\"961\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"962\" data-end=\"1464\"\u003e\n\u003cli data-section-id=\"1xurcm3\" data-start=\"962\" data-end=\"1000\"\u003ePhoenix Contact Part Number: 1076374\u003c\/li\u003e\n\u003cli data-section-id=\"uc14yo\" data-start=\"1001\" data-end=\"1040\"\u003eModel: CT-ES-60II-6010-98-1500-5A-C02\u003c\/li\u003e\n\u003cli data-section-id=\"1gfrgf7\" data-start=\"1041\" data-end=\"1074\"\u003eWindow-type current transformer\u003c\/li\u003e\n\u003cli data-section-id=\"ybjo1c\" data-start=\"1075\" data-end=\"1103\"\u003ePrimary current: 1500 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"12qeion\" data-start=\"1104\" data-end=\"1131\"\u003eSecondary current: 5 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"v0rm5h\" data-start=\"1132\" data-end=\"1157\"\u003eCurrent ratio: 1500\/5 A\u003c\/li\u003e\n\u003cli data-section-id=\"1clxtu5\" data-start=\"1158\" data-end=\"1179\"\u003eAccuracy class: 0.2\u003c\/li\u003e\n\u003cli data-section-id=\"1unk9fv\" data-start=\"1180\" data-end=\"1201\"\u003eRated burden: 20 VA\u003c\/li\u003e\n\u003cli data-section-id=\"ed6bge\" data-start=\"1202\" data-end=\"1238\"\u003eHigh-precision current measurement\u003c\/li\u003e\n\u003cli data-section-id=\"k7vubv\" data-start=\"1239\" data-end=\"1276\"\u003eSuitable for revenue-grade metering\u003c\/li\u003e\n\u003cli data-section-id=\"1e3be7d\" data-start=\"1277\" data-end=\"1330\"\u003eDesigned for power monitoring and energy management\u003c\/li\u003e\n\u003cli data-section-id=\"tqlw0v\" data-start=\"1331\" data-end=\"1363\"\u003eRobust industrial construction\u003c\/li\u003e\n\u003cli data-section-id=\"h9guxs\" data-start=\"1364\" data-end=\"1410\"\u003eEasy installation around existing conductors\u003c\/li\u003e\n\u003cli data-section-id=\"pd8dj0\" data-start=\"1411\" data-end=\"1464\"\u003eReliable performance in critical electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1466\" data-end=\"1482\"\u003e\u003cstrong data-start=\"1466\" data-end=\"1482\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1483\" data-end=\"1812\"\u003e\n\u003cli data-section-id=\"zrg7vf\" data-start=\"1483\" data-end=\"1508\"\u003eRevenue energy metering\u003c\/li\u003e\n\u003cli data-section-id=\"1w5udld\" data-start=\"1509\" data-end=\"1544\"\u003eUtility and substation monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1jzhixh\" data-start=\"1545\" data-end=\"1578\"\u003eEnergy management systems (EMS)\u003c\/li\u003e\n\u003cli data-section-id=\"c0rhxy\" data-start=\"1579\" data-end=\"1605\"\u003ePower quality monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"rb6wls\" data-start=\"1606\" data-end=\"1629\"\u003eIndustrial automation\u003c\/li\u003e\n\u003cli data-section-id=\"1vpv2cm\" data-start=\"1630\" data-end=\"1665\"\u003eBuilding management systems (BMS)\u003c\/li\u003e\n\u003cli data-section-id=\"zu8o49\" data-start=\"1666\" data-end=\"1698\"\u003eElectrical distribution panels\u003c\/li\u003e\n\u003cli data-section-id=\"17ubcts\" data-start=\"1699\" data-end=\"1728\"\u003eMotor control centers (MCC)\u003c\/li\u003e\n\u003cli data-section-id=\"6t279t\" data-start=\"1729\" data-end=\"1770\"\u003eCommercial and industrial power systems\u003c\/li\u003e\n\u003cli data-section-id=\"agvu03\" data-start=\"1771\" data-end=\"1812\"\u003eProtection and measurement applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":55170325807395,"sku":null,"price":600.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00007603_full_b408_79f05b61-3602-4c59-9ca2-848db3eb593b.jpg?v=1780239931"},{"product_id":"current-transformer-2500-5a-ct-es-80ii-8010-119-2500-5a-c02-class-0-2-40va-1076788","title":"Current Transformer 2500\/5A CT-ES-80II-8010-119-2500-5A-C02  Class 0.2 40VA 1076788","description":"\u003cp data-start=\"112\" data-end=\"969\"\u003eThe Phoenix Contact CT-ES-80II-8010-119-2500-5A-C02 (Part No. 1076788) is a high-precision window-type current transformer designed for accurate current measurement in high-capacity power distribution, energy management, and revenue metering applications. With a primary current rating of 2500 A AC and a secondary output of 5 A AC, it provides a precise 2500\/5 A transformation ratio for integration with energy meters, power analyzers, and monitoring systems. Featuring an accuracy class of 0.2 and a rated burden of 40 VA, this current transformer delivers exceptional measurement performance for critical industrial, commercial, and utility installations. Its robust window-type construction allows easy installation around busbars and large conductors in switchboards, substations, and electrical distribution systems.\u003c\/p\u003e\n\u003cp data-start=\"971\" data-end=\"987\"\u003e\u003cstrong data-start=\"971\" data-end=\"987\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"988\" data-end=\"1520\"\u003e\n\u003cli data-section-id=\"1xurfng\" data-start=\"988\" data-end=\"1026\"\u003ePhoenix Contact Part Number: 1076788\u003c\/li\u003e\n\u003cli data-section-id=\"1dt7u4b\" data-start=\"1027\" data-end=\"1067\"\u003eModel: CT-ES-80II-8010-119-2500-5A-C02\u003c\/li\u003e\n\u003cli data-section-id=\"1gfrgf7\" data-start=\"1068\" data-end=\"1101\"\u003eWindow-type current transformer\u003c\/li\u003e\n\u003cli data-section-id=\"1my259v\" data-start=\"1102\" data-end=\"1130\"\u003ePrimary current: 2500 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"12qeion\" data-start=\"1131\" data-end=\"1158\"\u003eSecondary current: 5 A AC\u003c\/li\u003e\n\u003cli data-section-id=\"j3eti\" data-start=\"1159\" data-end=\"1184\"\u003eCurrent ratio: 2500\/5 A\u003c\/li\u003e\n\u003cli data-section-id=\"1clxtu5\" data-start=\"1185\" data-end=\"1206\"\u003eAccuracy class: 0.2\u003c\/li\u003e\n\u003cli data-section-id=\"1um5c5p\" data-start=\"1207\" data-end=\"1228\"\u003eRated burden: 40 VA\u003c\/li\u003e\n\u003cli data-section-id=\"ed6bge\" data-start=\"1229\" data-end=\"1265\"\u003eHigh-precision current measurement\u003c\/li\u003e\n\u003cli data-section-id=\"fbr96q\" data-start=\"1266\" data-end=\"1316\"\u003eSuitable for revenue-grade metering applications\u003c\/li\u003e\n\u003cli data-section-id=\"jfrr27\" data-start=\"1317\" data-end=\"1378\"\u003eDesigned for energy management and power monitoring systems\u003c\/li\u003e\n\u003cli data-section-id=\"aqexi3\" data-start=\"1379\" data-end=\"1412\"\u003eDurable industrial construction\u003c\/li\u003e\n\u003cli data-section-id=\"1ufni72\" data-start=\"1413\" data-end=\"1462\"\u003eEasy installation around busbars and conductors\u003c\/li\u003e\n\u003cli data-section-id=\"1gn071p\" data-start=\"1463\" data-end=\"1520\"\u003eReliable operation in demanding electrical environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1522\" data-end=\"1538\"\u003e\u003cstrong data-start=\"1522\" data-end=\"1538\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1539\" data-end=\"1877\"\u003e\n\u003cli data-section-id=\"zrg7vf\" data-start=\"1539\" data-end=\"1564\"\u003eRevenue energy metering\u003c\/li\u003e\n\u003cli data-section-id=\"19vezkr\" data-start=\"1565\" data-end=\"1591\"\u003eUtility power monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"5irm6i\" data-start=\"1592\" data-end=\"1623\"\u003eIndustrial power distribution\u003c\/li\u003e\n\u003cli data-section-id=\"28igjf\" data-start=\"1624\" data-end=\"1660\"\u003eSubstations and switchgear systems\u003c\/li\u003e\n\u003cli data-section-id=\"1jzhixh\" data-start=\"1661\" data-end=\"1694\"\u003eEnergy management systems (EMS)\u003c\/li\u003e\n\u003cli data-section-id=\"1vpv2cm\" data-start=\"1695\" data-end=\"1730\"\u003eBuilding management systems (BMS)\u003c\/li\u003e\n\u003cli data-section-id=\"c0rhxy\" data-start=\"1731\" data-end=\"1757\"\u003ePower quality monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"17ubcts\" data-start=\"1758\" data-end=\"1787\"\u003eMotor control centers (MCC)\u003c\/li\u003e\n\u003cli data-section-id=\"vgs2rd\" data-start=\"1788\" data-end=\"1840\"\u003eCommercial and industrial electrical installations\u003c\/li\u003e\n\u003cli data-section-id=\"rbldgc\" data-start=\"1841\" data-end=\"1877\"\u003eProtection and measurement systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":55170339569955,"sku":null,"price":750.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00002726_full_b408.jpg?v=1780240828"},{"product_id":"chint-dtsu666-din-rail-three-phase-energy-meter-5-80a","title":"CHINT DTSU666 DIN-Rail Three Phase Energy Meter 3×230\/400V 5(80)A Digital kWh Meter Cat. #195291","description":"\u003ch2\u003eCHINT DTSU666 – DIN-Rail Three Phase Digital Energy Meter\u003c\/h2\u003e\u003cp\u003eThe CHINT DTSU666 is a DIN-rail mounted three-phase digital kWh energy meter for accurate measurement of electrical energy consumption in commercial and industrial installations. Operating at 3×230\/400V with a 5(80)A current range, it provides reliable, tamper-resistant energy metering with a clear digital display.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e CHINT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e DTSU666\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCat. No.:\u003c\/strong\u003e 195291\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Three-Phase Digital Energy Meter (kWh)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 3×230\/400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 5(80)A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN-Rail\u003c\/li\u003e\n\u003cli\u003eAccurate digital kWh measurement for three-phase systems\u003c\/li\u003e\n\u003cli\u003eClear digital display for easy reading\u003c\/li\u003e\n\u003cli\u003eSuitable for commercial and industrial energy monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eA reliable three-phase digital energy meter for accurate kWh measurement in commercial and industrial premises across Ghana.\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"Default Title","offer_id":55241034989859,"sku":null,"price":1000.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/51XqNyigbBL._AC_SX679.jpg?v=1781642340"},{"product_id":"chint-ddsu666-din-rail-single-phase-energy-meter-230v-5-80a","title":"CHINT DDSU666 DIN-Rail Single Phase Energy Meter 230V 5(80)A 2-Module Digital kWh Meter Cat. #195290","description":"\u003ch2\u003eCHINT DDSU666 – DIN-Rail Single Phase Digital Energy Meter\u003c\/h2\u003e\u003cp\u003eThe CHINT DDSU666 is a compact 2-module DIN-rail mounted single-phase digital kWh energy meter for accurate measurement of electrical energy consumption in residential and commercial installations. Operating at 230V with a 5(80)A current range, it delivers reliable energy metering in a space-saving 2-module form factor.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e CHINT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e DDSU666\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCat. No.:\u003c\/strong\u003e 195290\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Single-Phase Digital Energy Meter (kWh)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 5(80)A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e 2-Module DIN-Rail\u003c\/li\u003e\n\u003cli\u003eAccurate digital kWh measurement for single-phase systems\u003c\/li\u003e\n\u003cli\u003eCompact 2-module design for space-efficient panel layouts\u003c\/li\u003e\n\u003cli\u003eSuitable for residential and commercial energy monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eA compact and reliable single-phase digital energy meter for accurate kWh measurement in homes and commercial premises across Ghana.\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"Default Title","offer_id":55241035940131,"sku":null,"price":600.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/images-2026-06-16T204125.118.jpg?v=1781642507"},{"product_id":"phoenix-contact-eem-em157-ee-single-phase-electric-energy-measuring-device-230-v-45-a-direct-measurement-2-pulse-outputs-rs-485-interface-mid-certified-item-1311993","title":"Phoenix Contact EEM-EM157-EE – Single-Phase Electric Energy Measuring Device, 230 V \/ 45 A, Direct Measurement, 2 Pulse Outputs, RS-485 Interface, MID Certified (Item 1311993)","description":"\u003ch2\u003ePhoenix Contact EEM-EM157-EE — Single-Phase MID-Certified Energy Meter\u003c\/h2\u003e\u003cp\u003eThe EEM-EM157-EE is a Phoenix Contact single-phase electric energy measuring device for measuring active power in 230 V \/ 45 A power grids by direct measurement. MID-certified for billing-grade accuracy, it features 2 pulse outputs and an RS-485 interface for Modbus communication. Operating temperature up to 70°C. DIN rail mounting.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-phase\u003c\/strong\u003e active energy measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 230 V | \u003cstrong\u003eCurrent:\u003c\/strong\u003e 45 A (direct)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2 pulse outputs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRS-485 \/ Modbus interface\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e up to 70°C\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMID certified\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDIN rail mounting\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 1311993\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":55354923811107,"sku":"PC-EEM-EM157-EE-1311993","price":1100.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00039299_full_b408.jpg?v=1784569601"},{"product_id":"phoenix-contact-window-type-current-transformer-ct-es-40i-4010-75-500-5a-c05-500-a-ac-primary-5-a-ac-secondary-accuracy-class-0-5-10-va-rated-power-item-1076169","title":"Phoenix Contact Window-Type Current Transformer CT-ES-40I-4010-75-500-5A-C05 – 500 A AC Primary, 5 A AC Secondary, Accuracy Class 0.5, 10 VA Rated Power (Item 1076169)","description":"\u003ch2\u003ePhoenix Contact CT-ES-40I-4010-75-500-5A-C05 — 500\/5A Window-Type Current Transformer\u003c\/h2\u003e\u003cp\u003eThe CT-ES-40I-4010-75-500-5A-C05 is a Phoenix Contact window-type current transformer with a 500 A AC primary input and 5 A AC secondary output. Accuracy Class 0.5 ensures precise measurement for energy metering and power monitoring applications. With a rated burden of 10 VA, it is compatible with a wide range of measuring instruments and energy meters. The window-type design allows the primary conductor to pass through the aperture for easy installation without breaking the circuit.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary current:\u003c\/strong\u003e 500 A AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 A AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy class:\u003c\/strong\u003e 0.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated burden:\u003c\/strong\u003e 10 VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Window (through-hole)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 1076169\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eRatio:\u003c\/strong\u003e 500\/5 A | \u003cstrong\u003eClass:\u003c\/strong\u003e 0.5 | \u003cstrong\u003eBurden:\u003c\/strong\u003e 10 VA | \u003cstrong\u003eItem No.:\u003c\/strong\u003e 1076169\u003c\/li\u003e\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":55355161870627,"sku":"PC-CT-ES-40I-500-5A-C05-1076169","price":350.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00002722_full_b408.jpg?v=1784573429"},{"product_id":"phoenix-contact-window-type-current-transformer-ct-es-40i-4010-75-400-5a-c05-400-a-ac-primary-5-a-ac-secondary-accuracy-class-0-5-5-va-rated-power-item-1076168","title":"Phoenix Contact Window-Type Current Transformer CT-ES-40I-4010-75-400-5A-C05 – 400 A AC Primary, 5 A AC Secondary, Accuracy Class 0.5, 5 VA Rated Power (Item 1076168)","description":"\u003ch2\u003ePhoenix Contact CT-ES-40I-4010-75-400-5A-C05 — 400\/5A Window-Type Current Transformer\u003c\/h2\u003e\u003cp\u003eThe CT-ES-40I-4010-75-400-5A-C05 is a Phoenix Contact window-type current transformer with a 400 A AC primary input and 5 A AC secondary output. Accuracy Class 0.5 ensures precise measurement for energy metering and power monitoring applications. With a rated burden of 5 VA, it is compatible with a wide range of measuring instruments and energy meters. The window-type design allows the primary conductor to pass through the aperture for easy installation without breaking the circuit.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary current:\u003c\/strong\u003e 400 A AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 A AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy class:\u003c\/strong\u003e 0.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated burden:\u003c\/strong\u003e 5 VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Window (through-hole)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 1076168\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eRatio:\u003c\/strong\u003e 400\/5 A | \u003cstrong\u003eClass:\u003c\/strong\u003e 0.5 | \u003cstrong\u003eBurden:\u003c\/strong\u003e 5 VA | \u003cstrong\u003eItem No.:\u003c\/strong\u003e 1076168\u003c\/li\u003e\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":55355173994787,"sku":"PC-CT-ES-40I-400-5A-C05-1076168","price":300.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00002722_full_b408.jpg?v=1784573429"}],"url":"https:\/\/www.electricalsuppliesgh.com\/collections\/meters-energy-monitoring.oembed?page=2","provider":"Electrical Supplies Ghana ","version":"1.0","type":"link"}