Product Overview
The ABB 1SDA101116R1 is a high-capacity molded-case circuit breaker from the Tmax XT7S series. Rated for 1250 A, 4 poles (four-pole), and with front terminal (“F F”) fixed mounting, it features the advanced EKIP DIP LS/I electronic trip release. This device is designed for demanding industrial applications including transformer, generator, and main distribution protection. 

Key Specifications

  • Part Number: 1SDA101116R1. 

  • Series: Tmax XT7S. 

  • Rated Current (Iₙ / Iᵤ): 1250 A. 

  • Number of Poles: 4 (four-pole).

  • Trip Unit / Release: EKIP DIP LS/I solid-state electronic release. 

  • Mounting / Connection: Fixed installation, front‐terminal bolts (“F F”). 

  • Short-Circuit Breaking Capacity (Icu):

    • At ~380-415 V: 50 kA. 

    • At ~220-240 V: 85 kA.

    • Rated Insulation Voltage (Uᵢ): 1000 V. 

  • Rated Service / Operational Voltage: Up to 690 V AC.

  • Power Loss (per pole): ~57 W at rated conditions. 

  • Typical Net Weight: ~17.67 kg. 

  • Standards: Complies with IEC 60947-2 (low-voltage circuit-breaker standard). 

Features & Benefits

  • High current capacity: With 1250 A rated current, the breaker supports heavy duty feeders and large distribution systems.

  • Robust fault interruption: 50 kA (at ~400 V) and up to 85 kA (at ~220-240 V) short-circuit breaking capacity delivers strong protection in fault events.

  • Advanced electronic trip functionality: The EKIP DIP LS/I unit provides adjustable long-time, short-time and instantaneous trip settings, enabling higher selectivity and system protection flexibility.

  • Four-pole design: Ensures all phases plus neutral are protected/disconnected — useful in installations with neutral current or full system isolation requirements.

  • Front‐terminal fixed mounting: Front access wiring simplifies installation and servicing, and is space efficient within panel layouts.

  • Reliable brand and construction: Part of ABB’s well-established protection equipment line, built for industrial performance and durability.

Applications / Use Cases

  • Main distribution boards in industrial/commercial installations

  • Protection of generator sets, transformer feeders, switchboards

  • Critical power infrastructure (data centres, large HVAC systems, manufacturing plants)

  • Upgrades of legacy systems requiring high-capacity MCCBs with electronic trip functionality

Ordering & Package Information

  • Supplied as a single unit (MOQ = 1). 

  • EAN / GTIN: 8056221014199.

  • Original manufacturer packaging, Italy (typical origin).

Compliance & Safety

  • Designed and tested to IEC 60947-2 and relevant standards for low-voltage circuit-breakers.

  • High interrupting capacity ensures downstream equipment and wiring are protected in fault conditions.

  • Electronic trip increases reliability and reduces nuisance trips, contributing to uptime and protection.