{"product_id":"phoenix-contact-mm-ee-eem-em357-three-phase-energy-meter-100-a-rs-485-modbus-pulse-outputs","title":"Phoenix Contact MM-EE-EEM-EM357 Three-Phase Energy Meter 100 A RS-485 MODBUS Pulse Outputs","description":"\u003cp data-start=\"589\" data-end=\"1073\"\u003eThe \u003cstrong data-start=\"593\" data-end=\"647\"\u003ePhoenix Contact MM-EE-EEM-EM357 (Part No. 1744495)\u003c\/strong\u003e is a \u003cstrong data-start=\"653\" data-end=\"702\"\u003ethree-phase energy and power measuring device\u003c\/strong\u003e designed for industrial energy monitoring and control systems. It directly measures active power in \u003cstrong data-start=\"803\" data-end=\"842\"\u003ethree-phase networks up to 480 V AC\u003c\/strong\u003e and \u003cstrong data-start=\"847\" data-end=\"866\"\u003e100 A per phase\u003c\/strong\u003e with high precision, making it suitable for load tracking, efficiency monitoring, and power management in factories, commercial buildings, and industrial installations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1075\" data-end=\"1540\"\u003eFeaturing a \u003cstrong data-start=\"1087\" data-end=\"1132\"\u003eclear LCD display with white backlighting\u003c\/strong\u003e, the unit shows real-time energy values and other electrical parameters. It supports \u003cstrong data-start=\"1218\" data-end=\"1271\"\u003eModbus\/RTU communication over an RS-485 interface\u003c\/strong\u003e and provides \u003cstrong data-start=\"1285\" data-end=\"1320\"\u003etwo opto-isolated pulse outputs\u003c\/strong\u003e for integration with data loggers, building management systems, or automation controllers. The meter is \u003cstrong data-start=\"1425\" data-end=\"1442\"\u003eMID-certified\u003c\/strong\u003e for compliance with energy billing and reporting standards. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1542\" data-end=\"1799\"\u003eBuilt for robust performance, this DIN-rail-mount unit operates in a wide ambient temperature range up to \u003cstrong data-start=\"1648\" data-end=\"1658\"\u003e+70 °C\u003c\/strong\u003e, with \u003cstrong data-start=\"1665\" data-end=\"1727\"\u003eIP51 front protection and IP20 connection enclosure rating\u003c\/strong\u003e for safe, long-term installation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1801\" data-end=\"1826\"\u003e📌 Key Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1827\" data-end=\"2545\"\u003e\n\u003cli data-start=\"1827\" data-end=\"1883\"\u003e\n\u003cp data-start=\"1829\" data-end=\"1883\"\u003e\u003cstrong data-start=\"1829\" data-end=\"1839\"\u003eModel:\u003c\/strong\u003e Phoenix Contact MM-EE-EEM-EM357 (1744495)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1884\" data-end=\"1945\"\u003e\n\u003cp data-start=\"1886\" data-end=\"1945\"\u003e\u003cstrong data-start=\"1886\" data-end=\"1907\"\u003eMeasurement Type:\u003c\/strong\u003e Three-phase active energy and power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1946\" data-end=\"2017\"\u003e\n\u003cp data-start=\"1948\" data-end=\"2017\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1966\"\u003eVoltage Range:\u003c\/strong\u003e ~173 V–480 V AC (Ph-Ph) \/ ~100 V–276 V AC (Ph-N)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2018\" data-end=\"2088\"\u003e\n\u003cp data-start=\"2020\" data-end=\"2088\"\u003e\u003cstrong data-start=\"2020\" data-end=\"2038\"\u003eCurrent Range:\u003c\/strong\u003e Direct measurement up to \u003cstrong data-start=\"2064\" data-end=\"2076\"\u003e100 A AC\u003c\/strong\u003e per phase\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2089\" data-end=\"2143\"\u003e\n\u003cp data-start=\"2091\" data-end=\"2143\"\u003e\u003cstrong data-start=\"2091\" data-end=\"2105\"\u003eInterface:\u003c\/strong\u003e RS-485 with \u003cstrong data-start=\"2118\" data-end=\"2132\"\u003eModbus\/RTU\u003c\/strong\u003e protocol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2144\" data-end=\"2198\"\u003e\n\u003cp data-start=\"2146\" data-end=\"2198\"\u003e\u003cstrong data-start=\"2146\" data-end=\"2158\"\u003eOutputs:\u003c\/strong\u003e 2 passive opto-isolated pulse outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2199\" data-end=\"2240\"\u003e\n\u003cp data-start=\"2201\" data-end=\"2240\"\u003e\u003cstrong data-start=\"2201\" data-end=\"2213\"\u003eDisplay:\u003c\/strong\u003e LCD with white backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2241\" data-end=\"2305\"\u003e\n\u003cp data-start=\"2243\" data-end=\"2305\"\u003e\u003cstrong data-start=\"2243\" data-end=\"2262\"\u003eCertifications:\u003c\/strong\u003e \u003cstrong data-start=\"2263\" data-end=\"2280\"\u003eMID certified\u003c\/strong\u003e for energy measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2306\" data-end=\"2343\"\u003e\n\u003cp data-start=\"2308\" data-end=\"2343\"\u003e\u003cstrong data-start=\"2308\" data-end=\"2321\"\u003eMounting:\u003c\/strong\u003e DIN-rail compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2344\" data-end=\"2405\"\u003e\n\u003cp data-start=\"2346\" data-end=\"2405\"\u003e\u003cstrong data-start=\"2346\" data-end=\"2361\"\u003eProtection:\u003c\/strong\u003e \u003cstrong data-start=\"2362\" data-end=\"2378\"\u003eIP51 (front)\u003c\/strong\u003e \/ \u003cstrong data-start=\"2381\" data-end=\"2403\"\u003eIP20 (connections)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2406\" data-end=\"2446\"\u003e\n\u003cp data-start=\"2408\" data-end=\"2446\"\u003e\u003cstrong data-start=\"2408\" data-end=\"2427\"\u003eOperating Temp:\u003c\/strong\u003e −40 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2447\" data-end=\"2545\"\u003e\n\u003cp data-start=\"2449\" data-end=\"2545\"\u003e\u003cstrong data-start=\"2449\" data-end=\"2464\"\u003eConnection:\u003c\/strong\u003e Screw terminals for power \u0026amp; communications \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2547\" data-end=\"2689\"\u003eThis energy meter is ideal for \u003cstrong data-start=\"2578\" data-end=\"2604\"\u003epower usage monitoring\u003c\/strong\u003e, \u003cstrong data-start=\"2606\" data-end=\"2625\"\u003ebilling systems\u003c\/strong\u003e, \u003cstrong data-start=\"2627\" data-end=\"2650\"\u003eenergy optimization\u003c\/strong\u003e, and \u003cstrong data-start=\"2656\" data-end=\"2688\"\u003eindustrial energy dashboards\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54665645228323,"sku":null,"price":2500.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/00203138_full_b408.jpg?v=1768858743","url":"https:\/\/www.electricalsuppliesgh.com\/products\/phoenix-contact-mm-ee-eem-em357-three-phase-energy-meter-100-a-rs-485-modbus-pulse-outputs","provider":"Electrical Supplies Ghana ","version":"1.0","type":"link"}