🔧 Features & Benefits
-
Thermal‑magnetic trip unit (TM‑D): Adjustable overload protection (44.1–63 A) with fixed magnetic short‑circuit protection for dependable safety.
-
Fixed‑style mounting: Designed for a compact, robust installation with backplate support.
-
Compliance: Fully meets IEC 60947‑2 and EN 60947‑2 standards; class II insulation suitable for switchboards per IEC 60664‑1.
-
Durability: Built to endure 30,000 mechanical cycles and 12,000 electrical cycles, ensuring long-term reliability.
-
Protection degree: Rated IP40 with pollution degree 3 for rugged performance in industrial environments.
📐 Dimensions & Physical
-
Size: 105 × 161 × 86 mm (W × H × D)
-
Weight: Approx. 1.5–1.8 kg
🌡 Operating Conditions
-
Rated impulse withstand voltage (Uimp): 8 kV for high-voltage resilience.
-
Operating temperature range: –25 °C to +70 °C (storage –50 °C to +85 °C).
✅ Ideal For
Commercial, industrial, and infrastructure applications—especially tailored for small to medium-sized buildings—requiring reliable protection for electrical distribution systems. Perfectly suited for class II insulation switchboards.
🌱 Sustainability & Certifications
-
Green Premium product: Part of Schneider Electric’s eco-conscious line, featuring RoHS & REACh compliance, mercury-free construction, and recyclable packaging.
-
Environmental commitment: Designed with recyclability and extended service life in mind, supporting Schneider Electric’s goal of Net Zero emissions by 2050.
⚙️ Technical Summary (Quick Specs)
| Specification | Details |
|---|---|
| Poles | 3P / 3D |
| Rated Current | 63 A (at 40 °C) |
| Trip Unit | TM‑D (thermal‑magnetic) |
| Instantaneous Pick‑up (Ii) | 500 A fixed |
| Breaking Capacity (Icu) | 25 kA @ 380–415 VAC; 40 kA @ 220–240 VAC |
| Service Breaking Capacity (Ics) | Matches Icu at respective voltages |
| Mechanical Durability | 30,000 cycles |
| Electrical Durability | 12,000 cycles |
| Mounting & Connection | Fixed, screw terminals (front ingress/egress) |
| Insulation & Protection | Class II, IP40, pollution degree 3 |
| Rated Impulse Withstand Voltage | 8 kV |
| Operating Temperature Range | –25 °C to +70 °C |
| Dimensions (W × H × D) | 105 × 161 × 86 mm |
| Weight | ~1.5–1.8 kg |
| Ambient Storage Temperature | –50 °C to +85 °C |