{"product_id":"schneider-electric-g80n3tm800-gopact-mccb-g800n-800a-3p-50ka-415vac-tmd-3d","title":"Schneider Electric G80N3TM800 GoPact MCCB – G800N 800A 3P 50kA @ 415VAC TMD (3D)","description":"\u003cp data-start=\"131\" data-end=\"497\"\u003eThe \u003cstrong data-start=\"135\" data-end=\"180\"\u003eSchneider Electric G80N3TM800 GoPact MCCB\u003c\/strong\u003e is a high-performance \u003cstrong data-start=\"203\" data-end=\"255\"\u003e800A, 3-Pole moulded case circuit breaker (MCCB)\u003c\/strong\u003e engineered for reliable protection of low-voltage three-phase distribution systems. With a \u003cstrong data-start=\"347\" data-end=\"383\"\u003e50kA breaking capacity at 415VAC\u003c\/strong\u003e, this unit is designed to withstand and interrupt high fault currents in industrial and commercial installations.\u003c\/p\u003e\n\u003cp data-start=\"499\" data-end=\"717\"\u003eEquipped with a \u003cstrong data-start=\"515\" data-end=\"570\"\u003eThermal Magnetic (TMD) trip unit – 3D configuration\u003c\/strong\u003e, the breaker provides dependable overload and short-circuit protection for heavy-duty feeders, main incomers, and large power distribution panels.\u003c\/p\u003e\n\u003cp data-start=\"719\" data-end=\"898\"\u003eThis MCCB is ideal for switchboards, generator systems, transformer secondary protection, and industrial power networks where stability, safety, and fault resilience are critical.\u003c\/p\u003e\n\u003chr data-start=\"900\" data-end=\"903\"\u003e\n\u003ch2 data-start=\"905\" data-end=\"932\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"934\" data-end=\"1525\"\u003e\n\u003cli data-start=\"934\" data-end=\"967\"\u003e\n\u003cp data-start=\"936\" data-end=\"967\"\u003e\u003cstrong data-start=\"936\" data-end=\"946\"\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"968\" data-end=\"990\"\u003e\n\u003cp data-start=\"970\" data-end=\"990\"\u003e\u003cstrong data-start=\"970\" data-end=\"981\"\u003eSeries:\u003c\/strong\u003e GoPact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"991\" data-end=\"1021\"\u003e\n\u003cp data-start=\"993\" data-end=\"1021\"\u003e\u003cstrong data-start=\"993\" data-end=\"1008\"\u003eModel Code:\u003c\/strong\u003e G80N3TM800\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1022\" data-end=\"1047\"\u003e\n\u003cp data-start=\"1024\" data-end=\"1047\"\u003e\u003cstrong data-start=\"1024\" data-end=\"1039\"\u003eFrame Size:\u003c\/strong\u003e G800N\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1048\" data-end=\"1080\"\u003e\n\u003cp data-start=\"1050\" data-end=\"1080\"\u003e\u003cstrong data-start=\"1050\" data-end=\"1073\"\u003eRated Current (In):\u003c\/strong\u003e 800A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1081\" data-end=\"1121\"\u003e\n\u003cp data-start=\"1083\" data-end=\"1121\"\u003e\u003cstrong data-start=\"1083\" data-end=\"1103\"\u003eNumber of Poles:\u003c\/strong\u003e 3P (Three Pole)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1122\" data-end=\"1168\"\u003e\n\u003cp data-start=\"1124\" data-end=\"1168\"\u003e\u003cstrong data-start=\"1124\" data-end=\"1152\"\u003eBreaking Capacity (Icu):\u003c\/strong\u003e 50kA @ 415VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1169\" data-end=\"1216\"\u003e\n\u003cp data-start=\"1171\" data-end=\"1216\"\u003e\u003cstrong data-start=\"1171\" data-end=\"1206\"\u003eRated Operational Voltage (Ue):\u003c\/strong\u003e 415V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1217\" data-end=\"1279\"\u003e\n\u003cp data-start=\"1219\" data-end=\"1279\"\u003e\u003cstrong data-start=\"1219\" data-end=\"1238\"\u003eTrip Unit Type:\u003c\/strong\u003e TMD (Thermal-Magnetic, Fixed Settings)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1280\" data-end=\"1310\"\u003e\n\u003cp data-start=\"1282\" data-end=\"1310\"\u003e\u003cstrong data-start=\"1282\" data-end=\"1305\"\u003eTrip Configuration:\u003c\/strong\u003e 3D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1311\" data-end=\"1410\"\u003e\n\u003cp data-start=\"1313\" data-end=\"1340\"\u003e\u003cstrong data-start=\"1313\" data-end=\"1338\"\u003eProtection Functions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1343\" data-end=\"1410\"\u003e\n\u003cli data-start=\"1343\" data-end=\"1365\"\u003e\n\u003cp data-start=\"1345\" data-end=\"1365\"\u003eOverload (Thermal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1368\" data-end=\"1410\"\u003e\n\u003cp data-start=\"1370\" data-end=\"1410\"\u003eShort Circuit (Magnetic Instantaneous)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1411\" data-end=\"1452\"\u003e\n\u003cp data-start=\"1413\" data-end=\"1452\"\u003e\u003cstrong data-start=\"1413\" data-end=\"1431\"\u003eMounting Type:\u003c\/strong\u003e Fixed, Panel Mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1453\" data-end=\"1525\"\u003e\n\u003cp data-start=\"1455\" data-end=\"1525\"\u003e\u003cstrong data-start=\"1455\" data-end=\"1480\"\u003eApplication Category:\u003c\/strong\u003e Industrial \u0026amp; Commercial Power Distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1527\" data-end=\"1530\"\u003e\n\u003ch2 data-start=\"1532\" data-end=\"1554\"\u003eProtection Features\u003c\/h2\u003e\n\u003ch3 data-start=\"1556\" data-end=\"1600\"\u003e🔹 High Short-Circuit Withstand Capacity\u003c\/h3\u003e\n\u003cp data-start=\"1601\" data-end=\"1683\"\u003eRated at \u003cstrong data-start=\"1610\" data-end=\"1627\"\u003e50kA @ 415VAC\u003c\/strong\u003e, ensuring safe interruption in high-fault environments.\u003c\/p\u003e\n\u003ch3 data-start=\"1685\" data-end=\"1729\"\u003e🔹 Thermal-Magnetic Trip Unit (TMD – 3D)\u003c\/h3\u003e\n\u003cul data-start=\"1730\" data-end=\"1945\"\u003e\n\u003cli data-start=\"1730\" data-end=\"1797\"\u003e\n\u003cp data-start=\"1732\" data-end=\"1797\"\u003eThermal element protects against prolonged overload conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1798\" data-end=\"1867\"\u003e\n\u003cp data-start=\"1800\" data-end=\"1867\"\u003eMagnetic element provides instantaneous short-circuit protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1868\" data-end=\"1945\"\u003e\n\u003cp data-start=\"1870\" data-end=\"1945\"\u003eFixed trip settings ensure reliable and predictable protection performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1947\" data-end=\"1984\"\u003e🔹 Heavy-Duty 800A Current Rating\u003c\/h3\u003e\n\u003cp data-start=\"1985\" data-end=\"2093\"\u003eDesigned for high-load applications such as industrial incomers, generator feeders, and transformer outputs.\u003c\/p\u003e\n\u003ch3 data-start=\"2095\" data-end=\"2122\"\u003e🔹 Robust 3-Pole Design\u003c\/h3\u003e\n\u003cp data-start=\"2123\" data-end=\"2220\"\u003eSuitable for three-phase systems in commercial buildings, factories, and infrastructure projects.\u003c\/p\u003e\n\u003chr data-start=\"2222\" data-end=\"2225\"\u003e\n\u003ch2 data-start=\"2227\" data-end=\"2250\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul data-start=\"2252\" data-end=\"2475\"\u003e\n\u003cli data-start=\"2252\" data-end=\"2295\"\u003e\n\u003cp data-start=\"2254\" data-end=\"2295\"\u003eMain incomer breaker in LV switchboards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2296\" data-end=\"2330\"\u003e\n\u003cp data-start=\"2298\" data-end=\"2330\"\u003eIndustrial distribution panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2331\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2333\" data-end=\"2363\"\u003eGenerator protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2364\" data-end=\"2400\"\u003e\n\u003cp data-start=\"2366\" data-end=\"2400\"\u003eTransformer secondary protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2401\" data-end=\"2432\"\u003e\n\u003cp data-start=\"2403\" data-end=\"2432\"\u003eLarge motor feeder circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2433\" data-end=\"2475\"\u003e\n\u003cp data-start=\"2435\" data-end=\"2475\"\u003eCommercial building power distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2477\" data-end=\"2480\"\u003e\n\u003ch2 data-start=\"2482\" data-end=\"2515\"\u003eBenefits for Your Installation\u003c\/h2\u003e\n\u003cp data-start=\"2517\" data-end=\"2733\"\u003e✔ Reliable industrial-grade protection\u003cbr data-start=\"2555\" data-end=\"2558\"\u003e✔ High breaking capacity for critical systems\u003cbr data-start=\"2603\" data-end=\"2606\"\u003e✔ Compact and rugged MCCB construction\u003cbr data-start=\"2644\" data-end=\"2647\"\u003e✔ Trusted Schneider Electric quality\u003cbr data-start=\"2683\" data-end=\"2686\"\u003e✔ Ideal for Ghana power distribution projects\u003c\/p\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54775663952163,"sku":null,"price":10000.0,"currency_code":"GHS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0943\/0790\/9923\/files\/mccbSchneider.jpg?v=1772133488","url":"https:\/\/www.electricalsuppliesgh.com\/products\/schneider-electric-g80n3tm800-gopact-mccb-g800n-800a-3p-50ka-415vac-tmd-3d","provider":"Electrical Supplies Ghana ","version":"1.0","type":"link"}